Liquichek Immunoassay Plus Control

Liquichek Immunoassay Plus Control

Overview

A liquid, serum-based control with a comprehensive analyte menu for monitoring the precision of immunoassay and therapeutic drug monitoring tests

Read full description

Description

Description

Unity Software Solutions

Unity Software Solutions

Unity helps laboratories around the world optimize QC practices and make decisions in real time with tools
to create QC strategies and
manage risk.

Unity Data Management »

 

Peer Reporting Program

Peer Reporting Program

The Unity Interlaboratory Peer Program provides a cost-effective opportunity to compare and improve QC performance by utilizing data generated from thousands of laboratories worldwide.

Learn more about Unity »

Liquichek Immunoassay Plus Control is a liquid, human serum-based control that covers a vast array of today's most popular routine immunoassay analytes. Assigned values are available for all major automated analyzers, making it a highly efficient solution for laboratories that focus on routine tests. This independent control is available in two configurations, a standard vial and a compact vial with barcode. The compact vial is compatible with applicable automated platforms such as Siemens Dimension Vista and Abbott Alinity, allowing for quick and easy QC set up with the 2D barcode.

Liquichek Immunoassay Plus Control is designed for convenience in today’s busy immunoassay laboratory. With a comprehensive analyte menu, this product can consolidate two or more separate controls for immunoassay and therapeutic drug monitoring (TDM) procedures. The control is available in three levels, covering clinically relevant ranges. Multiple levels allow for monitoring of the test system’s reliability.

 

Order Online—Reserve Your Lots Today

QC Lot reservation and schedule delivery—Now available with online ordering.

Login or Register on My Bio-Rad today and start ordering and reserving »

 

Features

  • Consolidated menu of analytes—Contains more than 80 analytes for precision monitoring of clinical diagnostic immunoassay and TDM tests
  • Multiple configurations—InteliQ and compact vial offers ready-to-use convenience, eliminating handling errors
  • Patient-like material—Liquid, human serum-based control
  • Multiple levels— Trilevel control offers test system reliability monitoring   
  • Extensive value assignment listings—Allows for use of a wide range of testing methods on most major analyzer systems to help monitor the precision of multiple test procedures and improve confidence in patient test results.
  • Ease of use— Ready-to-use liquid state offers the convenience of not needing to reconstitute
  • Long shelf life—Reduces crossover studies which helps simplify workflow

 

Storage & Stability

Configuration Stability Shelf life Levels Format
5 mL 14 day open-vial stability at 2-8°C for most analytes 2 year shelf life at -20°C to -70°C 1, 2, 3, Trilevel & Trilevel MiniPak Standard vial
2.5 mL 4 day open-vial stability at 2-8°C for all analytes 2 year shelf life when stored at -20°C to -50°C Levels 1, 2, 3 & Trilevel MiniPak Compact vial

 

Analytes

    • 11-Deoxycortisol*¹
    • 17-α-Hydroxyprogesterone¹
    • 25-Hydroxy Vitamin D*¹
    • Acetaminophen
    • Aldosterone¹
    • Alphafetoprotein (AFP)
    • Amikacin
    • Amiodarone*¹
    • Amitriptyline*¹
    • Androstenedione¹
    • Angiotensin I*¹
    • Anti-Thyroglobulin (Anti-Tg)*¹
    • Anti-Thyroperoxidase (Anti-TPO)*¹
    • Caffeine
    • Carbamazepine
    • Carbamazepine (Free)**¹
    • CEA
    • Chloramphenicol**¹
    • CK-MB Isoenzyme
    • Cortisol¹
    • Cyclosporine¹
    • Dehydroepiandrosterone (DHEA)*¹
    • Desipramine**¹
    • DHEA Sulfate¹
    • Digoxin
    • Disopyramide**¹
    • Estradiol
    • Estriol (Free)¹
    • Estriol (Total)*¹
    • Estrogen (Total)**¹
    • Ethosuximide¹
    • Ferritin
    • Flecainide**¹
    • Folate
    • Fructosamine**¹
    • FSH
    • Gentamicin
    • hCG¹
    • hCG-β Subunit
    • hGH¹
    • Ibuprofen¹
    • Imipramine*¹
    • Immunoglobulin A (IgA)
    • Immunoglobulin E (IgE)
    • Immunoglobulin G (IgG)
    • Immunoglobulin M (IgM)
    • Insulin¹
    • Iron
    • Iron (TIBC)*¹
    • LH
    • Lidocaine
    • Lithium
    • N-Acetylprocainamide (NAPA)
    • Netilmicin*¹
    • Nortriptyline¹
    • PAP¹
    • Phenobarbital
    • Phenytoin
    • Phenytoin (Free)**¹
    • Primidone¹
    • Procainamide**
    • Progesterone¹
    • Prolactin
    • Propranolol¹
    • PSA
    • PSA (Free)
    • PTH-MM*¹
    • Quinidine¹
    • Salicylate
    • SHBG (Sex Hormone Binding Globulin)¹
    • Somatomedin-C*¹
    • T3 (Free)
    • T3 (Total)
    • T3 Uptake/T-Uptake
    • T4 (Free)
    • T4 (Total)
    • TBG¹
    • Testosterone¹
    • Testosterone (Free)¹
    • Theophylline
    • Thyroglobulin (Tg)*¹
    • Tobramycin
    • Tricyclic Antidepressants (TCA) Screen
    • TSH
    • Valproic Acid**
    • Valproic Acid (Free)¹
    • Vancomycin
    • Vitamin B12

*No claims are made regarding performance or stability.
**Values are not provided.
¹Not included in compact vial format.

Refer to My eInserts or the product insert (IFU) of currently available lots for specific analyte and stability claims.

 

Applications & Use

This product should be treated the same as patient specimens and used in accordance with the instructions accompanying the instrument, kit or reagent.

Before sampling, allow this product to reach room temperature (18°C to 25°C). If the product has been stored frozen, allow it to stand at room temperature (18°C to 25°C) until it is completely thawed. Store the thawed product at 2-8°C. If the product has been stored refrigerated, allow it to reach room temperature (18°C to 25°C) before use. Gently swirl the vial several times to ensure homogeneity. After each use promptly replace the stopper and return to 2-8°C storage.

 

How it Works

barcoded compact vial workflow

 

Related Categories

Therapeutic Drug Monitoring Controls
Immunology/Protein Quality Controls

 

Frequently Asked Questions

After use, how long can the control product be left out before returning to the refrigerator?  
Typically, if the product has been stored refrigerated, allow the product to reach room temperature (18°C to 25°C) before use (specific time limitations may apply, depending on the product). For optimal analyte stability, promptly return the product to the recommended storage temperature after each use.
What type of water should be used to reconstitute lyophilized control products?
Typically, distilled or deionized water is used. Please refer to the package insert for product specific reconstitution instructions.  
How long should the reconstituted control remain at room temperature prior to use?  
Upon reconstitution, the stopper should be replaced and the product should be allowed to stand at room temperature for the time period indicated in the product insert (IFU). Prior to use, gently swirl the vial to ensure homogeneity. Refer to the procedure section of the product insert (IFU) for product-specific handling instructions.  
How long should the frozen liquid controls sit at room temperature in order to thaw?  
Typically, the frozen product should be allowed to thaw at room temperature (18°C to 25°C) for the time indicated in the product insert (IFU) or until completely thawed prior to use. The product vial should be swirled gently to ensure homogeneity prior to use. Refer to the procedure section of the product insert (IFU) for product-specific handling instruction.  
What are the acceptable limits for room, refrigerator, and freezer temperature?  
This information is stated in the product insert (IFU):
  • Room temperature: 18°C to 25°
  • Refrigerator temperature: 2-8°C
  • Freezer temperature: -20°C to -70°C/-20°C to -50°C for 2.5 mL vial

Most frozen products recommend avoidance of frost-free freezers. There are exceptions, so refer to specific control insert.

Ordering

Ordering

items

Use the filters below to refine results!

Image
360_qsd_liqia_tn.jpg
360
Assayed, liquid human serum based control with up to 88 analytes to monitor precision of IA and TDM assays; trilevel, 4 of each level (12 x 5 mL)
Image
361_qsd_liqia_tn.jpg
361
Assayed, liquid human serum based control with up to 88 analytes to monitor precision of IA and TDM assays; level 1 of 3 (12 x 5 mL)
Image
362_qsd_liqia_tn.jpg
362
Assayed, liquid human serum based control with up to 88 analytes to monitor precision of IA and TDM assays; level 2 of 3 (12 x 5 mL)
Image
363_qsd_liqia_tn.jpg
363
Assayed, liquid human serum based control with up to 88 analytes to monitor precision of IA and TDM assays; level 3 of 3 (12 x 5 mL)
Image
360x_qsd_liqia_tn.jpg
360X
Assayed, liquid human serum based control with up to 88 analytes to monitor precision of IA and TDM assays; trilevel MiniPak (3 x 5 mL)
Image
qsd_267_tn.jpg
267
Assayed, liquid human serum based control with Siemens Dimension Vista® analytes to monitor precision of IA and TDM assays. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbot Alinity; level 1 of 3 (12 x 2.5 mL)
Image
qsd_268_tn.jpg
268
Assayed, liquid human serum based control with Siemens Dimension Vista® analytes to monitor precision of IA and TDM assays. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbot Alinity; level 2 of 3 (12 x 2.5 mL)
Image
qsd_269_tn.jpg
269
Assayed, liquid human serum based control with Siemens Dimension Vista® analytes to monitor precision of IA and TDM assays. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbot Alinity; level 3 of 3 (12 x 2.5 mL)
Image
qsd_268x_tn.jpg
268X
Assayed, liquid human serum based control with Siemens Dimension Vista® analytes to monitor precision of IA and TDM assays. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbot Alinity; trilevel MiniPak (3 x 2.5 mL)

Accessories

Accessories

Image
qsd_98700_tip_screwcap_tn.jpg
987000
Disposable plastic tip accessories for quality controls fitted with a screw cap closure. Enables fluid delivery directly from glass vial. 100/Package.

Documents

Documents

Number Description Options
Q-1659
Immunoassay Controls
[ Add to Cart (Free) ]
Q-1214
Bio-Rad Quality Control Products in Compact Vials
[ Add to Cart (Free) ]
Q-1118
Quality Control Products & Services Catalog
[ Add to Cart (Free) ]