Overview
Introducing the new range of EconoFit prepacked low-pressure columns, featuring new hardware which is fully compatible with the NGC Chromatography Systems. These convenient, easy to use, disposable columns are available in 1 ml and 5 ml sizes.
Choose from a wide selection of Bio-Rad Resins in prepacked format and accelerate your research.
EconoFit Columns deliver run-to-run uniformity for a range of chromatography applications that enable preparative scale purifications and/or rapid method development. They can be connected directly to NGC Systems, and other commonly used chromatography systems, using 10-32 fittings.
Ordering Options
Resin Chemistry | Media | 1 x 1 ml | 5 x 1 ml | 1 x 5 ml | 5 x 5 ml |
---|---|---|---|---|---|
Affinity | |||||
Nuvia IMAC, Ni-charged | 12009288 | 12009285 | 12009286 | 12009287 | |
Nuvia IMAC, Uncharged | 12009289 | – | – | – | |
Profinity IMAC, Ni-Charged | – | 12009298 | 12009299 | 12009300 | |
Profinity GST | – | 12009295 | 12009296 | 12009297 | |
Profinity eXact |
12009292 | 12009293 | 12009294 | – | |
Affi-Gel Blue | – | – | 12009234 | 12009235 | |
DEAE Affi-Gel Blue | – | – | 12009262 | 12009263 | |
Affi-Prep Protein A | – | 12009236 | 12009237 | – | |
UNOsphere SUPrA | 12009321 | 12009322 | 12009323 | – | |
Anion Exchange | |||||
Macro-Prep DEAE | 12009274 | 12009264 | 12009265 | 12009266 | |
Macro-Prep High Q | 12009275 | 12009267 | 12009268 | 12009269 | |
Macro-Prep High Q-3HT | 12009283 | – | – | – | |
UNOsphere Q | 12009307 | 12009301 | 12009302 | 12009303 | |
Nuvia Q | 12009290 | – | – | – | |
Nuvia HP-Q | 12009282 | – | – | – | |
Cation Exchange | |||||
Macro-Prep High S | 12009276 | 12009270 | 12009271 | 12009272 | |
Macro-Prep CM | 12009273 | – | – | – | |
UNOsphere S | 12009308 | 12009304 | 12009305 | 12009306 | |
Nuvia S | 12009291 | – | – | – | |
Nuvia HR-S | 12009284 | – | – | – | |
Hydrophobic Interaction | |||||
Macro-Prep Methyl | 12009277 | – | – | – | |
Macro-Prep t-Butyl | 12009278 | – | – | – | |
Mixed Mode | |||||
CHT Type I, 40 µm | 12009255 | – | 12009253 | 12009254 | |
CHT Type I, 80 µm | 12009256 | – | – | – | |
CHT Type II, 40 µm | 12009259 | – | 12009257 | 12009258 | |
CHT Type II, 80 µm | 12009260 | – | – | – | |
CFT Type II, 40 µm | 12009252 | – | 12009240 | 12009251 | |
CHT XT | 12009261 | – | – | – | |
MPC Type I, 40 µm | 12009279 | – | – | – | |
Nuvia aPrime 4A | 12009280 | – | – | – | |
Nuvia cPrime | 12009281 | – | – | – | |
Buffer Exchange | |||||
Bio-Gel P-6 Desalting | – | – | 12009238 | 12009239 |
More Columns for NGC Chromatography Systems
Related Products
Related Categories
Ordering
items
Use the filters below to refine results!
Pkg of 1, 5 ml, prepacked affinity column, 16 mm x 25 mm, max. pressure 10 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 5 ml, prepacked affinity columns, 16 mm x 25 mm, max. pressure 10 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 1 ml, prepacked affinity columns, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml, prepacked affinity column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml, prepacked affinity column, 16 mm x 25 mm, max. pressure 10 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 5 ml, prepacked affinity columns, 16 mm x 25 mm, max. pressure 10 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked Ni-charged IMAC column, 7 mm x 25 mm, max. pressure 45 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 1 ml, prepacked Ni-charged IMAC column, 7 mm x 25 mm, max. pressure 45 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml, prepacked Ni-charged IMAC column, 16 mm x 25 mm, max. pressure 45 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 5 ml, prepacked Ni-charged IMAC column, 16 mm x 25 mm, max. pressure 45 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked uncharged IMAC column, 7 mm x 25 mm, max. pressure 45 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 1 ml, prepacked affinity columns, 7 mm x 25 mm, max. pressure 43 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml, prepacked affinity column, 16 mm x 25 mm, max. pressure 43 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 5 ml, prepacked affinity columns, 16 mm x 25 mm, max. pressure 43 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 1 ml, prepacked Ni-charged column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml, prepacked Ni-charged column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 5 ml, prepacked Ni-charged column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked UNOsphere SUPrA Affinity Column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 1 ml, prepacked UNOsphere SUPrA Affinity Columns, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml, prepacked UNOsphere SUPrA Affinity Column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml column filled with Bio-Gel P-6 Gel Filtration (size exclusion) chromatography support; 16 mm x 25 mm, max. pressure 72 psi. Use EconoFit Bio-Gel P-6 Columns for desalting or buffer exchange with the NGC Chromatography System or any chromatography system
Pkg of 5, 5 ml columns filled with Bio-Gel P-6 Gel Filtration (size exclusion) chromatography support; 16 mm x 25 mm, max. pressure 72 psi. Use EconoFit Bio-Gel P-6 Columns for desalting or buffer exchange with the NGC Chromatography System or any chromatography system
Pkg of 1, 1 ml, prepacked hydrophobic interaction column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked hydrophobic interaction column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked weak cation exchange resin column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked anion exchange column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 1 ml, prepacked anion exchange column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml, prepacked anion exchange column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 5 ml, prepacked anion exchange column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked anion exchange column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 1 ml, prepacked anion exchange column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml, prepacked anion exchange column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 5 ml, prepacked anion exchange column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked anion exchange column, 7 mm x 25 mm, max. pressure 45 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked cation exchange column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 1 ml, prepacked cation exchange column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml, prepacked cation exchange column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 5 ml, prepacked cation exchange column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked anion exchange column, 7 mm x 25 mm, max. pressure 45 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked cation exchange column, 7 mm x 25 mm, max. pressure 45 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked anion exchange column, 7 mm x 25 mm, max. pressure 45 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked cation exchange column, 7 mm x 25 mm, max. pressure 45 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked affinity column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 1 ml, prepacked affinity columns, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml, prepacked affinity column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked anion exchange column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 1 ml, prepacked anion exchange column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml, prepacked anion exchange column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 5 ml, prepacked anion exchange column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked cation exchange column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 1 ml, prepacked cation exchange column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml, prepacked cation exchange column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 5 ml, prepacked cation exchange column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked mixed mode column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml, prepacked mixed mode column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 5 ml, prepacked mixed mode columns, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked mixed mode column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml, prepacked mixed mode column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 5 ml, prepacked mixed mode columns, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked mixed mode column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked mixed mode column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 5 ml, prepacked mixed mode column, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 5, 5 ml, prepacked mixed mode columns, 16 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked mixed mode column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked mixed mode column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked mixed mode column, 7 mm x 25 mm, max. pressure 72 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked hydrophobic anion exchange column, 7 mm x 25 mm, max. pressure 45 psi, for use with NGC Systems or any chromatography system
Pkg of 1, 1 ml, prepacked hydrophobic cation exchange column, 7 mm x 25 mm, max. pressure 45 psi, for use with NGC Systems or any chromatography system
Kits & Reagents
Packs
A pack combining 1 prepacked Nuvia IMAC Column and 1 prepacked Bio-Gel P-6 Desalting Column (both 5 ml, 16 mm x 25 mm) to facilitate purification of histidine-tagged proteins using NGC Systems or any chromatography system
A collection of four prepacked ceramic apatite chromatography columns, 7 mm x 25 mm, for media screening experiments and small-scale method development with NGC Systems or any chromatography system
A collection of five prepacked cation exchange chromatography columns, 7 mm x 25 mm, for resin screening experiments and small-scale method development with NGC Systems or any chromatography system
A collection of six prepacked anion exchange chromatography columns, 7 mm x 25 mm, for resin screening experiments and small-scale method development with NGC Systems or any chromatography system
A collection of six columns for the development of a non-affinity-based purification workflow for monoclonal antibodies.
A collection of six columns for the purification of large biomolecules.
A collection of four columns for screening and use in protein aggregate removal.