NGC 10 Medium-Pressure Chromatography Systems

Image
ngc-10-ml-systems-detail.jpg

Overview

The preconfigured NGC 10 Chromatography Systems meet a range of throughput and application needs. Each system can be easily upgraded. All configurations share a common software platform. For analytical and preparative chromatography.

Read full description Ordering Information

Description

Description

Contact an NGC Specialist

Try an NGC System in your lab

Try an NGC System in your lab

Request a Demo

The family of NGC Medium-Pressure Chromatography Systems fit your throughput requirements when purifying biomolecules for analytical- and preparative-scale applications. Each system is composed of interchangeable modules that confer different system capabilities.

The six preconfigured NGC Liquid Chromatography Systems listed below are designed with increasing automation and throughput to serve a wide range of laboratory needs:

  • NGC Quest 10 (7880001) and NGC Quest 10 Plus Systems (7880003) — for separating biomolecules at high resolution using accurate gradients
  • NGC Scout 10 (7880005) and NGC Scout 10 Plus Systems (7880007) — for medium throughput applications requiring rapid scouting of protein purification conditions with automated gradients and buffer preparation
  • NGC Discover 10 (12010343) and NGC Discover 10 Pro Systems (7880011) — for higher throughput applications with rapid, robust automation and a need for method development

For an overview of the features and capabilities of the six NGC Chromatography Systems, view the NGC 10 System comparison chart and watch the NGC System Tour.

The NGC Systems are composed of interchangeable modules that confer different system capabilities. Browse the module selection guide to help you decide which system is best for you, or use our online tool to configure your personalized NGC Instrument.

Multidimensional (Multi-D) Chromatography with NGC Systems

Multi-D chromatography is a feature of the NGC Systems that automates multistep purifications using complementary strategies to isolate your product of interest at high yields and purity levels run after run.

Compared to traditional sequential chromatography workflows, which require running single columns sequentially, Multi-D sets up an automated workflow and consolidates day-long methods to hour-long protocols without requiring the intervention of users, allowing them to save valuable time.

 

Resources for Converting to Automated Multi-D Chromatography

 
  • Automated Multi-Column Protein Purification with the NGC System

    This whiteboard animation video provides a brief introduction to Bio-Rad’s automated multi-column purification options (Multi-D purification) on Bio-Rad's NGC Preparative Chromatography System.

  • The Advantages of Multidimensional (Multi-D) Chromatography

    Watch the Multi-D Webinar to learn more about automating purifications, optimizing methods, and creating multidimensional chromatography method templates.

Features and Benefits of the NGC 10 ml Chromatography Systems

Flexible, customizable chromatography systems to suit both your application and workflow needs:

  • The guided fluidics selection tool (patent pending), coupled with the module discovery system, enables a single-click application-based system setup through automated module function recognition
  • The Tier Rotate Feature allows optimal placement of valves and detectors to minimize the flow path
  • Compact footprint — fits in a refrigerator, lab bench, or coldroom
  • Point-to-Plumb Feature shows the step-by-step plumbing of the system using LEDs
  • ChromLab Software provides powerful system control, automated methods, and analysis options
  • Multi-D setup automates multistep purifications and completes complex separation protocols without user involvement

Applications and Uses of Medium-Pressure Chromatography Systems

Other NGC Chromatography Systems

Bio-Rad also offers NGC Chromatography Systems with integrated 100 ml system pumps and NGC Fraction Collector as well as a variety of chromatography columns and resins.

Compatible Chromatography Columns

Designed specifically for NGC Chromatography Systems, these prepacked high-resolution columns work at high pressures and are optimized for the separation of biomolecules at fast flow rates.

 

More Information

 

Upgrade your NGC Chromatography System by adding more modular components to match your changing throughput and application requirements:

See how the NGC System benefits University of California researchers by increasing throughput and making it easier for students to become experts at protein purification.

Ordering

Ordering

items

Use the filters below to refine results!

ngc-quest-10-system-SKU-788-0001-thumb.jpg
7880001
Includes 10 ml/min pumps, single-wavelength (UV) and conductivity detection, and automated sample injection, for the purification of proteins
ngc-quest-10-plus-system-SKU-788-0003-thumb.jpg
7880003
Includes 10 ml/min pumps, multi-wavelength (UV/Vis) and conductivity detection, and automated sample injection, for the purification of proteins
ngc-scout-10-system-SKU-788-0005-thumb.jpg
7880005
Includes 10 ml/min pumps, single-wavelength (UV) and conductivity detection, buffer blending options, for rapid pH scouting during sample purification
ngc-scout-10-plus-system-SKU-788-0007-thumb.jpg
7880007
Includes 10 ml/min pumps, multi-wavelength (UV/Vis) and conductivity detection, buffer blending options, for rapid pH scouting during the purification of proteins, peptides, and nucleic acids
ngc-discover-10-system-SKU-788-0009-thumb.jpg
7880009
Includes 10 ml/min pumps, multi-wavelength (UV/Vis) and conductivity detection, expanded scouting options, large-sample injection, and column switching of up to 5 columns, for method development
ngc-discover-10-system-SKU-788-0011-thumb.jpg
7880011
Includes 10 ml/min pumps, multi-wavelength (UV/Vis) and conductivity detection, expanded scouting options, large-sample injection, outlet valve, and column switching of up to 5 columns, for method development

Accessories

Accessories

ngc-fraction-collector-with-racks-17002070-tn.jpg
17002070
Pkg of 1, NGC Fraction Collector, includes two 13 mm racks
NGC-Fraction-Collector-Enclosure-12009848-thumb.png
12009848
Protects fractions from dust and particulates.
741-0002_tn.jpg
7410002
100/240 V, fraction collector, includes power cord, rack set F1 (2 x flatpack, 13 mm), BioFrac Diverter Valve, fittings kit
ngc-expansion-bay-788-4000-thumb.jpg
7884000
Pkg of 1, expands a 2-tier NGC System to a 3-tier system for adding extra plug-and-play modules
pc-for-chromlab-788-4015-thumb.jpg
(Discontinued) Computer
7884015
PC for ChromLab™ Software and database, communicates with and stores data generated by the NGC™ System
monitor-for-chromlab-788-4027-thumb.jpg
(Discontinued) Monitor, 22"
7884027
22" monitor for use with 788-4015, for viewing chromatograms and actions performed on the PC
7884025
Pkg of 1, enables communication between the NGC™ Systems and accessories like the BioFrac™ Fraction Collector
ngc-stand-788-5040-thumb.jpg
7885040
Pkg of 1, for mounting touch screen to NGC Systems
ngc-column-holder-long-788-5038-thumb.jpg
(Discontinued) NGC Column Holder
7885038
Pkg of 1, magnetic holder, holds long columns and mounts on the front or the side of instrument
7885057-sku_tn.jpg
7885057
Pkg of 1, magnetic holder, dual clamp for holding long columns and mounts on the front or the side of instrument
ngc-tubing-organizer-large-SKU-788-5035-thumb.jpg
7885035
Pkg of 3, guides and holds 1/8" inlet tubing in an organized manner, for use with NGC Chromatography Systems
ngc-tubing-organizer-small-SKU-788-5042-thumb.jpg
7885042
Pkg of 3, guides and holds 1/16" inlet tubing in an organized manner, for use with NGC Chromatography Systems
ngc-cartridge-holder-SKU-788-5039-thumb.jpg
7885039
Pkg of 1, flexible magnetic holder, holds 1–10 ml cartridges and mounts on the front or the side of instrument
ngc-sample-wash-tube-holder-SKU-788-5041-thumb.jpg
7885041
Pkg of 1, holds two 50 ml Falcon Tubes, for use with NGC Systems
750-0566_tn.jpg
(Discontinued) Bottle Cap Kit
7500566
Fittings kit, includes 2 bottle caps, 2 plugs, for use with BioLogic DuoFlow™ and NGC™ Systems
750-0703_tn.jpg
(Discontinued) Inline Filter Kit
7500703
Filter kit, includes 1 inline filter and 2 replacement frits, for use with BioLogic DuoFlow™ and NGC™ Systems
750-0703_tn.jpg
(Discontinued) Inline Filter Kit
7500703
Filter kit, includes 1 inline filter and 2 replacement frits, for use with BioLogic DuoFlow™ and NGC™ Systems
750-0704_tn.jpg
(Discontinued) Replacement Frits
7500704
Pkg of 5, replacement fittings, for inline filter kit
ngc-signal-import-module-788-4016-thumb-ngc-100-medium-pressure-chromatography-systems.jpg
7884016
Pkg of 1, enables analog to digital signal conversion and connection to external detectors and third party autosamplers such as the C-96 Autosampler
750-0230_tn.jpg
7500230
Pkg of 1, for use with BioLogic DuoFlow™ and NGC™ Workstations
7885003_sku_tn.png
7885003
The NGC System Pump Maintenance Kit includes pump head seals, wash behind seals, wash behind check valves, check valves, O-rings, and small and large disks for servicing one NGC Chromatography F10 pump.
ph-probe-788-5026-thumb.jpg
7885026
Pkg of 1, for accurate pH monitoring (pH 1–14) during purifications performed to 200 ml/min, for use with the pH valve
ngc-buffer-tray-788-5014-thumb.jpg
(Discontinued) NGC™ Buffer Tray
7885014
Pkg of 1, holds up to 8 buffer bottles, includes drain port to prevent flooding in the event of a leak
ngc-drip-tray-788-5016-thumb.jpg
(Discontinued) NGC™ Drip Tray
7885016
Pkg of 1, for use with NGC Systems
ngc-expansion-bay-788-4000-thumb.jpg
7884000
Pkg of 1, expands a 2-tier NGC System to a 3-tier system for adding extra plug-and-play modules
ngc-expansion-bay-788-4001-thumb.jpg
7884001
Pkg of 1, expands a 3-tier NGC System to a 4-tier system for adding extra plug-and-play modules
ngc-blank-module-788-4005-thumb.jpg
(Discontinued) NGC™ Blank Module
7884005
Pkg of 1, blank module, for covering unused bays on the base and expansion layers
12012531_sku_tn.jpg
12012531
Pkg of 1, includes a 10 mm UV flow cell with an integrated conductivity monitor compatible with the NGC Multi-Wavelength II Detector Module (12010343) for analytical applications.
12012532_sku_tn.jpg
12012532
Pkg of 1, includes a 5 mm UV flow cell with an integrated conductivity monitor compatible with the NGC Multi-Wavelength II Detector Module. (12010343)
12012533_sku_tn.jpg
12012533
Pkg of 1, includes a 2 mm UV flow cell with an integrated conductivity monitor compatible with the NGC Multi-Wavelength II Detector Module (12010343) for preparative applications.
deu-lamp-replace-788-5001-thumb.jpg
7885001
Pkg of 1, UV lamp replacement for multi-wavelength detectors
tung-lamp-replace-788-5002-thumb.jpg
7885002
Pkg of 1, visible lamp replacement for multi-wavelength detectors
ngc-led-lamp-replacement-SKU-788-5000-thumb.jpg
7885000
Pkg of 1, 255/280 nm LED lamp replacement for single-wavelength UV detectors

Fittings

Fittings

ngc-fittings-kit-SKU-788-4017-thumb.jpg
(Discontinued) NGC™ Fittings Kit
7884017
Pkg of 1, kit includes multiple fittings, fittings maker, fittings tightener, ferrules, nuts, screwdrivers, pump head keys, and syringes required to set up, prepare, and prime NGC Systems
732-0113_tn.jpg
7320113
Low-pressure system fittings kit, includes 1/4–28 female to male and 1/4–28 female to female luers to connect 1 cartridge to BioLogic DuoFlow™ and NGC Systems
fittings-maker-magnetic-788-5043-thumb.jpg
7885043
For making fittings for 1/16" (1.6 mm) OD and 1/8" (3.2 mm) tubing
fittings-tightener-short-788-5008-thumb.jpg
7885008
Pkg of 1, short tool for tightening hard-to-reach fittings
750-0560_tn.jpg
7500560
Pkg of 1, fittings tool, for use with BioLogic DuoFlow and NGC Systems
peek-nut-1-16-SKU-788-5025-thumb.jpg
(Discontinued) PEEK Nut 1/16"
7885025
Pkg of 20, part of NGC™ fittings kit, for use with NGC Chromatography Systems
750-0556_tn.jpg
7500556
Pkg of 10, ferrule and lock ring, for 1/16" OD (1.6 mm) tubing, for use with BioLogic DuoFlow™ and NGC™ Systems
peek-nut-1-8-SKU-788-5015-thumb.jpg
(Discontinued) PEEK Nut 1/8"
7885015
Pkg of 10, part of NGC™ Fittings Kit, for use with NGC Chromatography Systems
peek-ferrule-1-8-SKU-788-5055-thumb.jpg
(Discontinued) PEEK Ferrule 1/8"
7885055
Pkg of 15, part of NGC™ fittings kit, for use with NGC Chromatography Systems
750-0563_tn.jpg
(Discontinued) Tefzel Plug
7500563
Pkg of 5, 1/4–28 male connection, to plug unused ports on valves and columns, for use with BioLogic DuoFlow™ and NGC™ Systems
no_image_feature.jpg
7885007
Pkg of 2, union for NGC™ Systems, 0.020" ID
no_image_feature.jpg
7885009
Pkg of 4 (qty 2 pairs — each with one 1/4-28 F to 10-32 M adaptor and one 1/4-28 M to 10-32 F adaptor)
750-0564_tn.jpg
7500564
Pkg of 2, fittings to connect one HPLC column (10-32) to BioLogic DuoFlow
750-0565_tn.jpg
7500565
Pkg of 2, fittings to connect one Econo-Column (luer) Column to BioLogic DuoFlow and NGC Systems
no_image_feature.jpg
7885010
Pkg of 10, includes five slip luer F to 10-32 M adaptors and five quick-connect luer M to 10-32 F adaptors
760-1308_tn.jpg
7601308
Fitting for tubing
760-1311_tn.jpg
7601311
Fitting for tubing
750-0559_tn.jpg
(Discontinued) Tefzel Cap
7500559
Pkg of 5, Tefzel caps, 1/4–28 female connection, to plug unused tubing, for use with BioLogic DuoFlow™ and NGC™ Systems
750-0561_tn.jpg
(Discontinued) Tefzel Union Adaptor
7500561
Pkg of 2, 1/4–28 to M6, to connect one M6 column to BioLogic DuoFlow™ and NGC™ Systems
750-0562_tn.jpg
(Discontinued) Tefzel Union
7500562
Pkg of 1, 1/4–28 to 1/4–28 to extend tubing, for use with BioLogic DuoFlow™ and NGC™ Systems
750-0568_tn.jpg
7500568
Fittings kit, includes 2 nuts and 4 ferrules to connect UNO Column to an HPLC system, for use with BioLogic DuoFlow™ and NGC™ Systems

Modules

Modules

12010343_thum.jpg
12010343
Pkg of 1, includes UV/Vis and conductivity detector kit with necessary tubing and fittings, for protein, peptide, nucleic acid, and chromophore detection
ngc-single-wavelength-detector-module-SKU-788-4008-thumb.jpg
7884008
Pkg of 1, includes UV/conductivity detector kit with necessary tubing and fittings, for nucleotide and protein detection, and salt gradient monitoring
ngc-ph-valve-module-SKU-788-4011-thumb.jpg
7884011
Pkg of 1, contains the pH valve kit, includes pH probe, tubing, fittings, for accurate inline pH measurement
ngc-sample-inject-valve-SKU-788-4007-thumb.jpg
7884007
Pkg of 1, kit includes necessary tubing, fittings, and a sample injection port, for automated application of small sample volume samples
ngc-inlet-valve-module-SKU-788-4006-thumb.jpg
7884006
Pkg of 1, kit includes necessary tubing and fittings, for automated switching between multiple buffers and samples during method development
ngc-outlet-valve-module-SKU-788-4013-thumb.jpg
7884013
Pkg of 1, kit includes necessary tubing and fittings for automated fraction collection of large-volume fractions with up to 12 vessels
ngc-buffer-blending-valve-module-SKU-788-4010-thumb.jpg
7884010
Pkg of 1, kit includes necessary tubing and fittings, for inline buffer preparation and pH gradient generation for quick pH scouting
ngc-column-switching-valve-module-10-ml-SKU-788-4012-thumb.jpg
7884012
Pkg of 1, kit includes the necessary tubing and fittings to accommodate up to 5 columns, for column scouting and reverse flow applications using 10 ml NGC Chromatography Systems
ngc-blank-module-788-4005-thumb.jpg
(Discontinued) NGC™ Blank Module
7884005
Pkg of 1, blank module, for covering unused bays on the base and expansion layers
ngc-air-sensor-module-SKU-788-5017-thumb.jpg
7885017
Pkg of 1, kit includes two large air sensors, protects against air entering pumps and columns
ngc-f10-pump-module-SKU-788-4002-thumb.jpg
7884002
Pkg of 1, includes 10 ml/min system pump kit with the necessary tubing and fittings, for creating buffer gradients
ngc-sample-pump-100-module-SKU-788-4004-thumb.jpg
7884004
Pkg of 1, includes 100 ml/min sample pump kit with the necessary tubing and fittings, for automated large-volume sample application
ngc-mixer-module-SKU-788-4018-thumb.jpg
(Discontinued) NGC Mixer Module
7884018

Pkg of 1, includes 10 ml/min kit with the necessary tubing and fittings, upgradable for use with F100 systems

Documents

Documents

Number Description Options
3229
Optimizing the NGC Chromatography System for Cryo-EM Applications Quick Guide
7260
Microbial Challenge and Sanitization of the NGC Discover 10 Pro System Using Sodium Hydroxide
7194
Integrating the CETAC MVX-7100 Autosampler with the NGC Chromatography System Protocol, Ver A
7208
NGC Chromatography System Connection Guide for Wyatt Instrumentation Protocol
[ Add to Cart (Free) ]
3211
Purification of Cas9 Nuclease with a Two-Step Chromatographic Process Application Note
7195
Integrating the CETAC MVX-7100 Autosampler with the NGC Chromatography System Quick Guide, Ver A
7205
NGC Liquid Chromatography System Quick Guide
7137
A Model System for Fast Screening of Optimal Protein Purification Conditions
7031
Integrating the ALIAS Autosampler with the NGC™ Chromatography System Protocol
6297
Foresight Prepacked Plates and Columns Product Information Sheet
6286
NGC Chromatography Systems Brochure
[ Add to Cart (Free) ]
7209
Chemical Compatibility with the NGC Chromatography System Flier, Ver A
[ Add to Cart (Free) ]
6326
NGC Chromatography Systems Module Selection Guide
[ Add to Cart (Free) ]
10000049090
NGC Chromatography Systems and ChromLab Software Installation Guide Version 6.1
10000049091
NGC Chromatography Systems and ChromLab Software Instrument Guide Version 6.1
10000049092
NGC Chromatography Systems and ChromLab Software User Guide Version 6.1
6879
Increasing Thoughput of a Tandem mAb Purification by Adding a High-Volume Autosampler to the NGC Chromatography System
6896
Integrating the CETAC ASX-560 Autosampler with the NGC™ Chromatography System
6608
NGC Chromatography Systems for Protein Purification in Drug Discovery and Development Brochure
[ Add to Cart (Free) ]
6963
NGC Fraction Collector Brochure
6674
NGC™ Chromatography Systems Multidimensional (Multi-D) Plumbing Guide
6377
Chromatography Success Guide
6701
Multidimensional (Multi-D) Chromatography Success Guide, Ver B
7277
Determination of Molecular Weight and Disperity of Antibody Samples Using Bio-Rad's NGC Chromatography System and Wyatt's MALS and RI Detectors
6694
Advantages of Multidimensional (Multi-D) Chromatography Using the NGC™ Chromatography System over Traditional Sequential Chromatography, Ver B
6725
From Optimization to Automation: Multidimensional (Multi-D) Histidine-Tag Protein Purification, Ver C
6745
Automated mAb Workflows: Combining Multidimensional (Multi-D) Purifications with Product Analysis, Ver C
6297
Foresight Prepacked Plates and Columns Product Information Sheet
6494
Protein Purification Workflow with the NGC Chromatography System and Stain-Free Gels Brochure
[ Add to Cart (Free) ]
6601
Enhancing the Flexibility of the NGC™ Chromatography System: Addition of a Refractive Index Detector for Wine Sample Analysis, Rev A
6529
Protein Purification and Crystallization of Diabetes Related Peroxisome Proliferator–Activated Receptor-γ (PPARγ), Rev A
6769
From Optimization to Automation: Multidimensional (Multi-D) Histidine-Tag Protein Purification (Poster), Ver A
6770
Automated mAb Workflows: Combining Multidimensional (Multi-D) Purifications with Product Analysis (Poster), Ver A
6805
Proven Method for Confirming Protein Purity and Yield Brochure
[ Add to Cart (Free) ]
6843
NGC Chromatography System Applications Publication List
[ Add to Cart (Free) ]
6675
ChromLab™ Software Product Information Sheet
3251
Cas9 Nuclease Preparation Using EconoFit Columns and the NGC Chromatography System Application Note