Bio-Gel® P Polyacrylamide Beads

Bio-Gel® P Polyacrylamide Beads

Overview

Bio-Gel P Polyacrylamide Beads are prepared for high-resolution gel filtration by copolymerization of acrylamide and N,N'-methylene-bis-acrylamide.
Read full description

Description

Description

Bio-Gel P Polyacrylamide Beads are designed for high-resolution gel filtration; they are prepared by copolymerization of acrylamide and N,N'-methylene-bis-acrylamide.

Featuures and Benefits of Bio-Gel P Polyacrylamide Beads

  • Available in several particle size ranges with molecular weight exclusion limits ranging from 100 to 100,000
  • Extremely hydrophilic and essentially nonionic
  • Provide efficient, gentle gel filtration of sensitive compounds
  • Do not support microbial growth or leach carbohydrates (due to their synthetic composition) as dextrose and agarose gels can

Bio-Gel P Beads are autoclavable at pH 5.5–6.5 and operate over a pH range of 2–10 at room temperature. Flow rate and resolution increase with increasing temperature in the range of 4–80°C.

Bio-Gel P Beads are compatible with dilute organic acids, 8 M urea, chaotropic agents, detergents, and miscible organic solvents. Alcohol (up to 20% v/v) can be used to enhance the solubility of nucleotides, peptides, and tannins without altering the exclusion properties of the gels. Formamide may also be used at full strength since Bio-Gel P Beads are completely swollen in this solvent.

Bio-Gel P-6DG Gel, with a molecular weight exclusion limit of 6,000, is recommended specifically for desalting and buffer exchange applications. It provides rapid results with high sample recovery and minimal sample dilution. Its hydrophilicity ensures little or no interaction between the gel and sample molecules.

More Information

Desalting With Bio-Gel P-6DG Desalting Gel (Bulletin 2068)

Ordering

Ordering

items

Use the filters below to refine results!

Image
150-4114_tn.jpg
(Discontinued) Bio-Gel P-2 Gel
1504114
100 g, fine polyacrylamide beads for size exclusion chromatography, 45–90 µm wet bead size, 100–1,800 MW fractionation range
Image
150-4115_tn.jpg
(Discontinued) Bio-Gel P-2 Gel
1504115
500 g, fine polyacrylamide beads for size exclusion chromatography, 45–90 µm wet bead size, 100–1,800 MW fractionation range
Image
150-4118_tn.jpg
(Discontinued) Bio-Gel P-2 Gel
1504118
100 g, extra fine polyacrylamide beads for size exclusion chromatography, <45 µm wet bead size, 100–1,800 MW fractionation range
Image
150-4120_tn.jpg
(Discontinued) Bio-Gel P-4 Gel
1504120
100 g, medium polyacrylamide beads for size exclusion chromatography, 90–180 µm wet bead size, 800–4,000 MW fractionation range
Image
150-4124_tn.jpg
(Discontinued) Bio-Gel P-4 Gel
1504124
100 g, fine polyacrylamide beads for size exclusion chromatography, 45–90 µm wet bead size, 800–4,000 MW fractionation range
Image
150-4128_tn.jpg
(Discontinued) Bio-Gel P-4 Gel
1504128
100 g, extra fine polyacrylamide beads for size exclusion chromatography, <45 µm wet bead size, 800–4,000 MW fractionation range
Image
150-4130_tn.jpg
(Discontinued) Bio-Gel P-6 Gel
1504130
100 g, medium polyacrylamide beads for size exclusion chromatography, 90–180 µm wet bead size, 1,000–6,000 MW fractionation range
Image
150-4134_tn.jpg
(Discontinued) Bio-Gel P-6 Gel
1504134
100 g, fine polyacrylamide beads for size exclusion chromatography, 45–90 µm wet bead size, 1,000–6,000 MW fractionation range
Image
150-0738_tn.jpg
(Discontinued) Bio-Gel P-6DG Gel
1500738
100 g, polyacrylamide beads for size exclusion chromatography, 90–180 µm wet bead size, 1,000–6,000 MW fractionation range
Image
150-0739_tn.jpg
(Discontinued) Bio-Gel P-6DG Gel
150-0739
1 kg, fine polyacrylamide beads for size exclusion chromatography, 90–180 µm wet bead size, 1,000–6,000 MW fractionation range
Image
150-4140_tn.jpg
(Discontinued) Bio-Gel P-10 Gel
1504140
100 g, medium polyacrylamide beads for size exclusion chromatography, 90–180 µm wet bead size, 1,500–20,000 MW fractionation range
Image
150-4144_tn.jpg
(Discontinued) Bio-Gel P-10 Gel
1504144
100 g, fine polyacrylamide beads for size exclusion chromatography, 45–90 µm wet bead size, 1,500–20,000 MW fractionation range
Image
150-4150_tn.jpg
(Discontinued) Bio-Gel P-30 Gel
1504150
100 g, medium polyacrylamide beads for size exclusion chromatography, 90–180 µm wet bead size, 2,500–40,000 MW fractionation range
Image
150-4154_tn.jpg
(Discontinued) Bio-Gel P-30 Gel
1504154
100 g, fine polyacrylamide beads for size exclusion chromatography, 45–90 µm wet bead size, 2,500–40,000 MW fractionation range
Image
150-4160_tn.jpg
(Discontinued) Bio-Gel P-60 Gel
1504160
100 g, medium polyacrylamide beads for size exclusion chromatography, 90–180 µm wet bead size, 3,000–60,000 MW fractionation range
Image
150-4164_tn.jpg
(Discontinued) Bio-Gel P-60 Gel
1504164
100 g, fine polyacrylamide beads for size exclusion chromatography, 45–90 µm wet bead size, 3,000–60,000 MW fractionation range
Image
150-4170_tn.jpg
(Discontinued) Bio-Gel P-100 Gel
1504170
100 g, medium polyacrylamide beads for size exclusion chromatography, 90–180 µm wet bead size, 5,000–100,000 MW fractionation range
Image
150-4174_tn.jpg
(Discontinued) Bio-Gel P-100 Gel
1504174
100 g, fine polyacrylamide beads for size exclusion chromatography, 45–90 µm wet bead size, 5,000–100,000 MW fractionation range

Documents

Documents

Number Description Options
7045
Resin and Column Selection Guide
[ Add to Cart (Free) ]
LIT174
Instruction Manual, Bio-Gel P Polyacrylamide Gel, Rev B
LIT547
Notice for Extra Fine P-Gel Users
2068
Desalting With Bio-Gel P-6DG Desalting Gel, Rev B
6906
Speciality Beads: Bio-Gel™ Resins Flier, Ver A