iMark™ Microplate Absorbance Reader

Image
lsr_imarkabsorbance_microreader.jpg

Overview

The iMark microplate absorbance reader offers fast reading speeds, extensive onboard software capabilities, a preprogrammed validation protocol (for the Checkmark reader performance check plate).
Read full description Ordering Information

Description

Description

Ask a Bio-Plex Specialist

Speak with a Specialist about the iMark System.

Contact an Expert

The iMark™ Microplate Absorbance Reader, with a wavelength range of 400–750 nm, is an economical, high-performance solution for a wide range of applications, including immunoassays with colorimetric substrates, such as ELISA, and protein assays such as Bradford and Lowry. The instrument can be used as a stand-alone reader or be controlled by a PC or Mac with Microplate Manager® 6 Software

Features and Benefits of the iMark Reader

  • Fast microplate reading speeds
  • Extensive onboard assay configuration
  • Powerful data analysis capabilities
  • Convenient built-in shaker
  • Space-saving, wide-format internal thermal graphical printer
  • Simplified standalone operation
  • Compact, easy-to-use, and lightweight design
  • Compatible with different types of 96-well microplates (flat, U-, V-bottom) and 8- or 12-well strip plates; maximum plate height: 16 mm

Features and Benefits of the iMark Reader Onboard Software

  • Wide applicability for life science and clinical laboratories
  • Programmable kinetic reading
  • Security login that allows locking and unlocking of key protocol settings by the administrator
  • Generous memory capacity for protocol creation and storage
  • Comprehensive curve-fit selections
  • Extensive reporting functions
  • Preprogrammed protocols for the Checkmark™ Reader performance verification kit, to validate the IQ/OQ/PQ of the iMark Reader in compliance with GLP
  • Other life science and specialized protocols included such as for the Bio-Rad TSE kits and a growing number of food testing and clinical kits

The iMark Reader comes with six standard absorbance filters: 415, 450, 490, 595, 655, and 750 nm. Bio-Rad also supplies custom filters at 5 nm intervals from 400 to 750 nm on request.

Plate Compatibility

  • Compatible with standard 96-well microplates 128 mm L x 88 mm W
  • Plate height cannot exceed 16 mm
  • Clear flat-bottom plates  are recommended such as Bio-Rad's Costar 96–Well Flat–Bottom EIA Plate (2240096)
  • U-Bottom plates can be used, but V-bottom plates are not recommended

Specifications

Specifications

Wavelength range
400–750 nm
Photometric range
0.0–3.5 OD
Linearity
≤1.0% from 0.0–2.0 OD; ≤2.0% from 0.0–3.0 OD
Accuracy
≤1.0% or 0.010 from 0.000–3.000 OD at 490 nm
Precision
1.0% or 0.005 OD from 0.0–2.0 OD; 1.5% from 2.0–3.0 OD
Resolution
0.001 OD
Filter wheel capacity
8
Plate shaking (3 speeds)
Low, mid, high
Duration, sec
0–999
Read time
6 sec at single wavelength, 10 sec at dual wavelengths
Data output
Onboard graphical thermal printer and USB2 interface with PC or Mac data stations
Data storage
Calender/clock functions; 64 assay protocols
Multilanguage support
4 languages, LCD indication supported; printout report supported
Dimensions (W x D x H), cm (in)
34.6 x 37.7 x 16.4 (13.6 x 14.8 x 6.5)
Weight, kg (lb)
5.5 (12)

Ordering

Ordering

items

Use the filters below to refine results!

168-1130_tn.jpg
1681130
100/240 V, includes 415, 450, 490, 595, 655, and 750 nm filters, built-in plate shaker, onboard software and thermal printer, one roll printer paper, USB and power cables
168-1135_tn.jpg
1681135
100/240 V, includes 415, 450, 490, 595, 655, and 750 nm filters, plate shaker, onboard software and thermal printer, printer paper, USB and power cables, Microplate Manager™ 6
170-7009_tn.jpg
1707009
100/240 V, microplate washer, includes bottle and tubing, 8-port manifold, aerosol protection cover, compatible with flat-, U-, and V-bottom plates

Accessories

Accessories

168-1006_tn.jpg
1682006
Pkg of 1, replacement lamp for use with iMark microplate absorbance reader
168-1007_tn.jpg
1682007
Pkg of 3 rolls, replacement thermal paper for the built-in printer on the iMark microplate absorbance reader (#168-1130)
168-9520_tn.jpg
1689520
Version 6.3, software intended for collection, analysis, and output of absorbance data from Bio-Rad's iMark™ microplate absorbance reader and xMark™ microplate absorbance spectrophotometer only
168-6940_tn.jpg
1686940
Absorbance calibration plate for use with all Bio-Rad absorbance microplate readers, includes Checkmark software to allow GLP compliance

Kits & Reagents

Kits & Reagents

500-0122_tn.jpg
5000122
Colorimetric assay kit, includes RC Reagents Package, DC™ Protein Assay Reagents Package, BSA standard; 450 standard assays
500-0121_tn.jpg
5000121
Colorimetric assay kit, includes RC Reagents Package, DC™ Protein Assay Reagents Package, bovine γ-globulin standard; 450 standard assays
500-0204_tn.jpg
5000204
Colorimetric assay kit, includes 1x dye reagent (1 L), bovine γ-globulin standard set (2 sets of 7 standards, 0.125–2.0 mg/ml, 2 ml)
500-0203_tn.jpg
5000203
Colorimetric assay kit, includes 1x dye reagent (1 L), bovine γ-globulin standard (5 x 2 mg/ml)
500-0202_tn.jpg
5000202
Colorimetric assay kit, includes 1x dye reagent (1 L), BSA standard set (2 sets of 7 standards, 0.125–2.0 mg/ml, 2 ml)
500-0201_tn.jpg
5000201
Colorimetric assay kit, includes 1x dye reagent (1 L), BSA standard (5 x 2 mg/ml); 200 standard assays or 4,000 microplate assays
500-0112_tn.jpg
5000112
Detergent-compatible colorimetric assay kit, includes 250 ml alkaline copper tartrate, 2 L dilute Folin reagent, 5 ml surfactant solution, BSA standard; 450 assays
500-0111_tn.jpg
5000111
Detergent-compatible colorimetric assay kit, includes 250 ml alkaline copper tartrate, 2 L dilute Folin reagent, 5 ml surfactant solution, bovine γ-globulin standard; 450 assays
500-0002_tn.jpg
5000002
Colorimetric assay kit, includes 450 ml dye reagent concentrate, bovine serum albumin standard; for 440 standard assays or 2,200 microplate assays
500-0001_tn.jpg
5000001
Colorimetric assay kit, includes 450 ml dye reagent concentrate, bovine γ-globulin standard; for 440 standard assays or 2,200 microplate assays
172-2055_tn.jpg
1722055
Panel includes 10 ml each rabbit anti-mouse subclass-specific antiserum to mouse IgG-1, IgG-2a, IgG-2b, IgG-3, IgM, IgA, κ- and λ-chains, sufficient for 100 typings
1722051
Antibody isotyping kit for ELISA, sufficient for 100 typings (800 tests), includes mouse isotyping panel (#172-2055), affinity purified goat anti-rabbit IgG (H + L)
172-1068_tn.jpg
1721068
100 ml, single-component EIA substrate solution, contains TMB and H2O2, detection wavelength 450 nm
172-1067_tn.jpg
1721067
For detection of HRP-labeled antibodies, kit contains 900 ml TMB solution and 100 ml hydrogen peroxide, detection wavelength 450 nm
172-1066_tn.jpg
1721066
Peroxidase substrates, for immunodetection, kit contains 180 ml TMB solution and 20 ml hydrogen peroxide, detection wavelength 450 nm
172-1064_tn.jpg
(Discontinued) HRP Substrate Kit
1721064
Horseradish peroxidase substrates, for immunodetection, includes 180 ml ABTS, 20 ml hydrogen peroxide, detection wavelength 415 nm
172-1063_tn.jpg
(Discontinued) AP Substrate Kit
1721063
Alkaline phosphatase substrates, for immunodetection, includes 100 pNPP tablets, 100 ml 5x concentrate diethanolamine buffer, for 500 ml
172-1037_tn.jpg
1721037
1 ml, EIA-grade, enzyme-antibody conjugate
172-1034_tn.jpg
1721034
1 ml, EIA-grade, enzyme-antibody conjugate
172-1033_tn.jpg
1721033
1 ml, EIA-grade, enzyme-antibody conjugate
172-1019_tn.jpg
1721019
1 ml, EIA-grade, enzyme-antibody conjugate
172-1017_tn.jpg
1721017
1 ml, EIA-grade, enzyme-antibody conjugate
172-1011_tn.jpg
1721011
2 ml, EIA-grade, enzyme-antibody conjugate

Filters

Filters

168-1010_tn.jpg
(Discontinued) 400 nm Filter
1681010
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1011_tn.jpg
(Discontinued) 405 nm Filter
1681011
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark™ (#168-1130) microplate readers
168-1012_tn.jpg
(Discontinued) 410 nm Filter
1681012
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1013_tn.jpg
(Discontinued) 415 nm Filter
1681013
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 420 nm Filter
1681014
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 425 nm Filter
1681015
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1016_tn.jpg
(Discontinued) 430 nm Filter
1681016
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 435 nm Filter
1681017
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 440 nm Filter
1681018
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 445 nm Filter
1681019
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1020_tn.jpg
(Discontinued) 450 nm Filter
1681020
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 455 nm Filter
1681021
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 460 nm Filter
1681022
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 465 nm Filter
1681023
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1024_tn.jpg
(Discontinued) 470 nm Filter
1681024
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1025_tn.jpg
(Discontinued) 475 nm Filter
1681025
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1026_tn.jpg
(Discontinued) 480 nm Filter
1681026
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1027_tn.jpg
(Discontinued) 485 nm Filter
1681027
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1028_tn.jpg
(Discontinued) 490 nm Filter
1681028
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1029_tn.jpg
(Discontinued) 495 nm Filter
1681029
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1030_tn.jpg
(Discontinued) 500 nm Filter
1681030
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1031_tn.jpg
(Discontinued) 505 nm Filter
1681031
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1032_tn.jpg
(Discontinued) 510 nm Filter
1681032
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1033_tn.jpg
(Discontinued) 515 nm Filter
1681033
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1034_tn.jpg
(Discontinued) 520 nm Filter
1681034
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1035_tn.jpg
(Discontinued) 525 nm Filter
1681035
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1036_tn.jpg
(Discontinued) 530 nm Filter
1681036
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1037_tn.jpg
(Discontinued) 535 nm Filter
1681037
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1038_tn.jpg
(Discontinued) 540 nm Filter
1681038
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1039_tn.jpg
(Discontinued) 545 nm Filter
1681039
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1040_tn.jpg
(Discontinued) 550 nm Filter
1681040
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 555 nm Filter
1681041
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1042_tn.jpg
(Discontinued) 560 nm Filter
1681042
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1043_tn.jpg
(Discontinued) 565 nm Filter
1681043
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1044_tn.jpg
(Discontinued) 570 nm Filter
1681044
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1045_tn.jpg
(Discontinued) 575 nm Filter
1681045
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1046_tn.jpg
(Discontinued) 580 nm Filter
1681046
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1047_tn.jpg
(Discontinued) 585 nm Filter
1681047
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1048_tn.jpg
(Discontinued) 590 nm Filter
1681048
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1049_tn.jpg
(Discontinued) 595 nm Filter
1681049
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1050_tn.jpg
(Discontinued) 600 nm Filter
1681050
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark™ (#168-1130) microplate readers
168-1051_tn.jpg
(Discontinued) 605 nm Filter
1681051
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark™ (#168-1130) microplate readers
168-1052_tn.jpg
(Discontinued) 610 nm Filter
1681052
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark™ (#168-1130) microplate readers
168-1053_tn.jpg
(Discontinued) 615 nm Filter
1681053
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark™ (#168-1130) microplate readers
168-1054_tn.jpg
(Discontinued) 620 nm Filter
1681054
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark™ (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 625 nm Filter
1681055
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1056_tn.jpg
(Discontinued) 630 nm Filter
1681056
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark™ (#168-1130) microplate readers
168-1057_tn.jpg
(Discontinued) 635 nm Filter
1681057
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark™ (#168-1130) microplate readers
168-1058_tn.jpg
(Discontinued) 640 nm Filter
1681058
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark™ (#168-1130) microplate readers
168-1059_tn.jpg
(Discontinued) 645 nm Filter
1681059
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark™ (#168-1130) microplate readers
168-1060_tn.jpg
(Discontinued) 650 nm Filter
1681060
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1061_tn.jpg
(Discontinued) 655 nm Filter
1681061
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 660 nm Filter
1681062
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 665 nm Filter
1681063
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1064_tn.jpg
(Discontinued) 670 nm Filter
1681064
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1065_tn.jpg
(Discontinued) 675 nm Filter
1681065
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1066_tn.jpg
(Discontinued) 680 nm Filter
1681066
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 685 nm Filter
1681067
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1068_tn.jpg
(Discontinued) 690 nm Filter
1681068
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 695 nm Filter
1681069
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1070_tn.jpg
(Discontinued) 700 nm Filter
1681070
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1071_tn.jpg
(Discontinued) 705 nm Filter
1681071
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 710 nm Filter
1681072
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 715 nm Filter
1681073
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 720 nm Filter
1681074
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 725 nm Filter
1681075
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1014_tn.jpg
(Discontinued) 730 nm Filter
1681076
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1077_tn.jpg
(Discontinued) 735 nm Filter
1681077
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1078_tn.jpg
(Discontinued) 740 nm Filter
1681078
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1079_tn.jpg
(Discontinued) 745 nm Filter
1681079
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers
168-1080_tn.jpg
(Discontinued) 750 nm Filter
1681080
Pkg of 1, filter for use with Model 680 (#168-1000) and iMark (#168-1130) microplate readers

Microplates

Microplates

224-0096_tn.jpg
2240096
Box of 20 packages, 5 high binding enzyme immunoassay plates per package (100 plates), polystyrene

Documents

Documents

Number Description Options
1069
Colorimetric Protein Assays, Rev D
5670
iMark Microplate Absorbance Reader Insert, Rev B
[ Add to Cart (Free) ]
10011683
Instruction Manual, Microplate Manager v. 6.0, Rev B