Designed to monitor precision at lower Troponin values for high-sensitivity Troponin assays.
 

Read full description

Description

Description

Unity Software Solutions

Unity Software Solutions

Unity helps laboratories around the world optimize QC practices and make decisions in real time with tools
to create QC strategies and
manage risk.

Unity Data Management »

 

Peer Reporting Program

Peer Reporting Program

The Unity Interlaboratory Peer Program provides a cost-effective opportunity to compare and improve QC performance by utilizing data generated from thousands of laboratories worldwide.

Learn more about Unity »

Liquichek Cardiac Markers Plus Control LT is an assayed, liquid, human serum-based, multi-analyte control designed to monitor precision at lower Troponin values for high-sensitivity Troponin assays. This comprehensive cardiac assessment control offers a variety of Troponin levels (1, 1A, 1B, 1C) to monitor assay precision around the clinically significant 99th percentile upper reference limit (URL) and includes values for BNP, CK, CK-MB, CRP, Digitoxin, Myoglobin and NT-proBNP. The low level offers lower target values for all analytes.

This control is available in two configurations, a standard vial and a compact vial with barcode. The compact vial is compatible with applicable automated platforms such as the Siemens Dimension Vista and Abbott Alinity, while the 2D barcode allows for quick and easy QC setup.

Liquichek Cardiac Markers Plus Control LT provides options to monitor a wide range of assays across the AMR as well as offers analytes that are assayed for multiple systems.

 

Order Online—Reserve Your Lots Today

QC Lot reservation and schedule delivery—Now available with online ordering.

Login or Register on My Bio-Rad today and start ordering and reserving »

 

Features

  • Consolidated menu of analytes—Contains multiple analytes, including Troponin I and T at lower levels, for monitoring clinical cardiac marker testing at the 99th percentile upper reference limit
  • Patient-like materials—Liquid, human control
  • Multiple levels—Clinically relevant targets and ranges to help monitor the precision of test methods
  • Extensive value assignment listings—Allows for use of a wide range of testing methods on most major analyzer systems to help compare data from multiple test platforms and improve confidence in patient test results
  • Ease of use—Ready-to-use liquid state offers the convenience of not needing to reconstitute
  • Long shelf life—Reduces crossover studies which helps simplify workflow

 

Storage & Stability

Configuration Stability Shelf life Levels Format
3 mL 20 day open-vial stability at 2-8°C with exceptions 3 years at -20°C to -70°C 1, 1A, 1B, 1C, 2, 3, Low & single level MiniPaks Standard vial
2.5 mL 5 day open-vial stability at 2-8°C for all analytes 3 years at -20°C to -50°C 1C, 2, 3 & Trilevel MiniPak Compact vial

 

Analytes

    • BNP
    • CK (Total)
    • CK-MB Isoenzyme
    • CRP
    • Digitoxin
    • Homocysteine*
    • Myoglobin
    • NT-proBNP
    • Troponin I
    • Troponin T**

*No claim is made for expected values or stability.
**Not available in 2.5mL fill size (only on product sheet)

Refer to My eInserts or the product insert (IFU) of currently available lots for specific analyte and stability claims.

 

Application & Use

This product should be treated the same as patient specimens and used in accordance with the instructions accompanying the instrument, kit or reagent.

Allow the frozen product to thaw at room temperature (18°C to 25°C) for approximately 30 minutes or until completely thawed prior to use. Gently swirl the vial several times to ensure homogeneity. After each use promptly replace the stopper and return to 2-8°C storage.

If the product has been stored refrigerated, allow it to reach room temperature (18°C to 25°C) before use. Before sampling, gently swirl the vial several times to ensure homogeneity.
To prepare aliquot samples, allow the control vial to thaw as described above. Gently swirl the vial several times to ensure homogeneity, then dispense the control material into aliquot vials and store at -20°C to -70°C. If sampling aliquot, use it only once. Discard the remaining material.

 

Related Products

InteliQ Cardiac Markers Plus LT
InteliQ Homocysteine Control
Liquichek Cardiac Troponins Control
Liquichek Homocysteine Control
InteliQ Quality Controls

 

Frequently Asked Questions

After use, how long can the control product be left out before return to refrigerator?
Typically, if the product has been stored refrigerated, allow the product to reach room temperature (18°C to 25°C) before use (specific time limitations may apply, depending on the product). For optimal analyte stability, promptly return the product to the recommended storage temperature after each use.
How long should frozen liquid controls sit at room temperature in order to thaw?
Typically, the frozen product should be allowed to thaw at room temperature (18°C to 25°C) for the time indicated in the product insert (IFU) or until completely thawed prior to use. The product vial should be swirled gently to ensure homogeneity prior to use. Refer to the procedure section of the product insert (IFU) for product-specific handling instruction.
What are the acceptable limits for room, refrigerator, and freezer temperature?
This information is stated in the product insert (IFU):
  • Room temperature: 18°C to 25°C
  • Refrigerator temperature: 2-8°C
  • Freezer temperature: -20°C to -70°C/-20°C to -50°C for 2.5 mL vial

Most frozen products recommend avoidance of frost-free freezers. There are exceptions, so refer to specific control insert.

Ordering

Ordering

items

Use the filters below to refine results!

Image
146_qsd_cmplt_tn.jpg
146
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods, assayed for multiple systems (6 x 3mL)
Image
qsd_27104_tn.jpg
27104
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods, assayed for multiple systems (6 x 3mL)
Image
qsd_27105_tn.jpg
27105
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods, assayed for multiple systems (6 x 3mL)
Image
qsd_27106_tn.jpg
27106
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods, assayed for multiple systems (6 x 3mL)
Image
147_qsd_cmplt_tn.jpg
147
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods, assayed for multiple systems (6 x 3mL)
Image
148_qsd_cmplt_tn.jpg
148
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods, assayed for multiple systems (6 x 3mL)
Image
149_qsd_cmplt_tn.jpg
149
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision at lower concentrations of cardiac assessment analytes, assayed for multiple systems (6 x 3mL)
Image
qsd_146_x_tn.jpg
146X
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods, assayed for multiple systems (1 x 3mL)
Image
qsd_147_x_tn.jpg
147X
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods, assayed for multiple systems (1 x 3mL)
Image
qsd_148_x_tn.jpg
148X
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods, assayed for multiple systems (1 x 3mL)
Image
qsd_149_x_tn.jpg
149X
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision at lower concentrations of cardiac assessment analytes, assayed for multiple systems (1 x 3mL)
Image
qsd_27104_x_tn.jpg
27104X
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods, assayed for multiple systems (1 x 3mL)
Image
qsd_27105_x_tn.jpg
27105X
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods, assayed for multiple systems (1 x 3mL)
Image
qsd_27106_tn.jpg
27106X
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods, assayed for multiple systems (1 x 3mL)
Image
qsd_297_tn.jpg
297

Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity (6 x 2.5 mL)

Image
qsd_298_tn.jpg
298

Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity (6 x 2.5 mL)

Image
qsd_299_tn.jpg
299

Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity (6 x 2.5 mL)

Image
qsd_298_x_tn.jpg
298X

Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity. Includes 1 vial of each level (3 x 2.5 mL)

Accessories

Accessories

Image
qsd_98700_tip_screwcap_tn.jpg
987000
Disposable plastic tip accessories for quality controls fitted with a screw cap closure. Enables fluid delivery directly from glass vial. 100/Package.

Documents

Documents

Number Description Options
Q-1521
Cardiac Assessment Controls
[ Add to Cart (Free) ]
Q-1214
Bio-Rad Quality Control Products in Compact Vials
[ Add to Cart (Free) ]
Q-1118
Quality Control Products & Services Catalog
[ Add to Cart (Free) ]