Description
Description
Unity Software Solutions
Unity helps laboratories around the world optimize QC practices and make decisions in real time with tools
to create QC strategies and
manage risk.
Peer Reporting Program
The Unity Interlaboratory Peer Program provides a cost-effective opportunity to compare and improve QC performance by utilizing data generated from thousands of laboratories worldwide.
Liquichek Cardiac Markers Plus Control LT is an assayed, liquid, human serum-based, multi-analyte control designed to monitor precision at lower Troponin values for high-sensitivity Troponin assays. This comprehensive cardiac assessment control offers a variety of Troponin levels (1, 1A, 1B, 1C) to monitor assay precision around the clinically significant 99th percentile upper reference limit (URL) and includes values for BNP, CK, CK-MB, CRP, Digitoxin, Myoglobin and NT-proBNP. The low level offers lower target values for all analytes.
This control is available in two configurations, a standard vial and a compact vial with barcode. The compact vial is compatible with applicable automated platforms such as the Siemens Dimension Vista and Abbott Alinity, while the 2D barcode allows for quick and easy QC setup.
Liquichek Cardiac Markers Plus Control LT provides options to monitor a wide range of assays across the AMR as well as offers analytes that are assayed for multiple systems.
Order Online—Reserve Your Lots Today
QC Lot reservation and schedule delivery—Now available with online ordering.
Login or Register on My Bio-Rad today and start ordering and reserving »
Features
- Consolidated menu of analytes—Contains multiple analytes, including Troponin I and T at lower levels, for monitoring clinical cardiac marker testing at the 99th percentile upper reference limit
- Patient-like materials—Liquid, human control
- Multiple levels—Clinically relevant targets and ranges to help monitor the precision of test methods
- Extensive value assignment listings—Allows for use of a wide range of testing methods on most major analyzer systems to help compare data from multiple test platforms and improve confidence in patient test results
- Ease of use—Ready-to-use liquid state offers the convenience of not needing to reconstitute
- Long shelf life—Reduces crossover studies which helps simplify workflow
Storage & Stability
Configuration | Stability | Shelf life | Levels | Format |
---|---|---|---|---|
3 mL | 20 day open-vial stability at 2-8°C with exceptions | 3 years at -20°C to -70°C | 1, 1A, 1B, 1C, 2, 3, Low & single level MiniPaks | Standard vial |
2.5 mL | 5 day open-vial stability at 2-8°C for all analytes | 3 years at -20°C to -50°C | 1C, 2, 3 & Trilevel MiniPak | Compact vial |
Analytes
-
- BNP
- CK (Total)
- CK-MB Isoenzyme
- CRP
- Digitoxin
- Homocysteine*
- Myoglobin
- NT-proBNP
- Troponin I
- Troponin T**
*No claim is made for expected values or stability.
**Not available in 2.5mL fill size (only on product sheet)
Refer to My eInserts or the product insert (IFU) of currently available lots for specific analyte and stability claims.
Application & Use
This product should be treated the same as patient specimens and used in accordance with the instructions accompanying the instrument, kit or reagent.
Allow the frozen product to thaw at room temperature (18°C to 25°C) for approximately 30 minutes or until completely thawed prior to use. Gently swirl the vial several times to ensure homogeneity. After each use promptly replace the stopper and return to 2-8°C storage.
If the product has been stored refrigerated, allow it to reach room temperature (18°C to 25°C) before use. Before sampling, gently swirl the vial several times to ensure homogeneity.
To prepare aliquot samples, allow the control vial to thaw as described above. Gently swirl the vial several times to ensure homogeneity, then dispense the control material into aliquot vials and store at -20°C to -70°C. If sampling aliquot, use it only once. Discard the remaining material.
Related Products
InteliQ Cardiac Markers Plus LT
InteliQ Homocysteine Control
Liquichek Cardiac Troponins Control
Liquichek Homocysteine Control
InteliQ Quality Controls
Frequently Asked Questions
- Room temperature: 18°C to 25°C
- Refrigerator temperature: 2-8°C
- Freezer temperature: -20°C to -70°C/-20°C to -50°C for 2.5 mL vial
Most frozen products recommend avoidance of frost-free freezers. There are exceptions, so refer to specific control insert.
Ordering
Ordering
items
Use the filters below to refine results!
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity (6 x 2.5 mL)
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity (6 x 2.5 mL)
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity (6 x 2.5 mL)
Liquid, human serum based, comprehensive cardiac assessment control designed to monitor the precision of cardiac assessment test methods. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity. Includes 1 vial of each level (3 x 2.5 mL)