Profinia Protein Purification System Buffers and Reagents

Profinia Protein Purification System Buffers and Reagents

Overview

Individually packaged reagents are available for use with the Profinia system. Reagents can also be used for general affinity purification workflows, from sample preparation to protein detection.

Read full description

Description

Description

Individually packaged reagents are also available for use with the Profinia system. While designed specifically to work with the Profinia system, these reagents also have general applicability within all stages of a purification workflow, from sample preparation to protein detection.

Profinia Bottled Buffers
For added convenience, preformulated buffers are available for native IMAC, GST, and desalting purifications.

Profinia Control Lysate
The Profinia control lysate is a lyophilized, dual-tagged 51 kD target protein that is meant to eliminate concerns over variability in purification buffer solutions or in the purification matrix itself. The control lysate facilitates system setup and initial purification and is included in every Profinia native IMAC and GST starter kit.

Urea and Glutathione Reagents
Powdered urea and glutathione reagents are available for use with denaturing IMAC and GST applications, respectively. The urea packs are ideal for solubilizing and denaturing proteins in E. coli extracts. The glutathione pack is essential for eluting GST fusion proteins from immobilized glutathione resins.

His and GST Antibodies
Histidine (His)-tagged and GST-tagged monoclonal antibodies are used to detect target protein expression of overexpressed 6x His and GST fusion proteins. They are supplied at a concentration of 1 mg/ml in phosphate buffered saline, pH 7.4 with 0.05% NaN3.

Related Products

Ordering

Ordering

items

Use the filters below to refine results!

Image
620-0203_tn.jpg
(Discontinued) His Antibody
6200203
Pkg of 1 vial, 1 mg/ml, monoclonal antibody against histidine (His)-tagged proteins, for use with the Profinia protein purification system
Image
620-0205_tn.jpg
6200205
125 ml, preformulated concentrate, 600 mM KCl, 100 mM KH2PO4, 10 mM imidazole, pH 8.0, for use with His-tag protein purification
Image
620-0206_tn.jpg
6200206
125 ml, preformulated concentrate, 600 mM KCl, 100 mM KH2PO4, 10 mM imidazole, pH 8.0, for use with His-tag protein purification
Image
620-0207_tn.jpg
6200207
100 ml, preformulated concentrate, 600 mM KCl, 100 mM KH2PO4, 20 mM imidazole, pH 8.0, for use with His-tag protein purification
Image
620-0213_tn.jpg
(Discontinued) GST Lysis buffer, 2x
6200213
125 ml, preformulated concentrate, 300 mM NaCl, 20 mM Na2HPO4, 10 mM EDTA, pH 7.4, for use with GST-tag protein purification
Image
620-0214_tn.jpg
(Discontinued) GST Wash buffer, 2x
6200214
200 ml, preformulated concentrate, 300 mM NaCl, 20 mM Na2HP04, 10 mM EDTA, pH 7.4, for use with GST-tag protein purification
Image
620-0216_tn.jpg
(Discontinued) Desalting Buffer, 5x
6200216
200 ml, preformulated concentrate, contains NaCl, KCl, Na2HPO4, KH2PO4, pH 7.0, for use with protein desalting
Image
620-0233_tn.jpg
6200233
Lyophilized, dual-tagged 51 kD protein for system setup and initial purification, for use with the Profinia protein purification system

Cartridges

Cartridges

Image
732-4646_tn.jpg
7324646
Pkg of 2, 1 ml, prepacked affinity column, 40 mm x 5.6 mm, max. pressure 45 psi, for use with BioLogic chromatography and Profinia systems
Image
732-4647_tn.jpg
7324647
Pkg of 4, 1 ml, prepacked affinity column, 40 mm x 5.6 mm, max. pressure 45 psi, for use with BioLogic chromatography and Profinia systems
Image
732-4648_tn.jpg
7324648
Pkg of 1, 5 ml, prepacked affinity column, 40 mm x 12.6 mm, max. pressure 45 psi, for use with BioLogic chromatography and Profinia systems
Image
732-5304_tn.jpg
7325304
Pkg of 5, 10 ml, prepacked gel filtration column, 80 mm x 12.6 mm, max. pressure 45 psi, for use with BioLogic™, Profinia™ and other chromatography systems
Image
732-5312_tn.jpg
7325312
Pkg of 1, 50 ml, prepacked gel filtration column, 80 mm x 28.2 mm, max. pressure 40 psi, for use with BioLogic™, Profinia™ and other chromatography systems
Image
732-5314_tn.jpg
7325314
Pkg of 5, 50 ml, prepacked gel filtration column, 80 mm x 28.2 mm, max. pressure 40 psi, for use with BioLogic™, Profinia™ and other chromatography systems

Documents

Documents

Number Description