D-10 Hemoglobin Testing System

D-10 Hemoglobin Testing System

The D-10 System provides automated HbA1c testing and HbA2/F/A1c testing in one compact platform.

Read More
Ordering Information

Overview

The D-10 System provides comprehensive, automated hemoglobin testing in a compact footprint. At only 15.8 inches (40.2 cm) wide by 21 inches (53.4 cm) deep by 19.5 inches (49.5 cm) high, the D-10 System requires a minimum amount of laboratory space.

Combining HbA1c and HbA2/F/A1c testing on a single platform, the system offers simple, efficient operation for clinics, physician offices, or clinical laboratories. Developed for flexibility and reliability, the D-10 System features an automatic system startup checklist and touchscreen operation, as well as onboard QC monitoring to ensure reliable results. One-step cartridge switching, automatic sample barcode reading, remote support, interfacing with the laboratory information system (LIS), and the option to export chromatograms contribute to increased workflow efficiency.

Specifications

Electrical Data
Power input requirements: 100-240 V~; 50-60 Hz
Power consumption: 220 VA max
Environmental Conditions
Dimensions
Sample capacity
10 samples; 50 samples and continuous loading with rack loader (optional)
Emissions
Heat generation: 1,010 BTU/hr max
Sound level: <70 dBA

Ordering

items

Use the filters below to refine results!

Accessories

Kits & Reagents

Image
dbu_220_0201_tn.jpg
220-0201
D-10 reagents and supplies for 400 hemoglobin A1c or 200 hemoglobin A2/F/A1c (β-thalassemia) tests
Image
740_qsd_lydib_tn.jpg
740
Assayed, lyophilized human whole blood based control for monitoring HbA1c for diabetes; bilevel (6x 0.5 mL)
Image
Liquichek Diabetes Level 1
12011343

Assayed, liquid, human whole blood based control for monitoring Hemoglobin A1C associated with diabetes; level 1 of 3 (6 x 1 ml)

Image
dbu_172_tn.jpg
12011344

Assayed, liquid, human whole blood based control for monitoring Hemoglobin A1C associated with diabetes; level 2 of 3 (6 x 1 ml)

Image
dbu_173_tn.jpg
12011345

Assayed, liquid, human whole blood based control for monitoring Hemoglobin A1C associated with diabetes; level 3 of 3 (6 x 1 ml)

Image
qsd_12000070_hba1c_tn.jpg
12000070
Human whole blood based control designed to verify linearity throughout the patient reportable range of HbA1c assays (6 x 0.5 mL, 1 of each level)
Image
553_qsd_hba2_tn.jpg
553
Assayed, lyophilized human whole blood based control for monitoring procedures for measurements of Hb variants A2, F, and S; bilevel (4 x 0.5 mL)
Image
bc80_qsd_eqhb_tn.jpg
BC80
External quality assurance services for 12 monthly tests of HbA1c, HbA2 and Total Glycated Hb for peer group result comparison (12 x 0.5 mL)

Documents

Number Description
[ Add to Cart (Free) ]