VARIANT II TURBO Hemoglobin Testing System

VARIANT II TURBO Hemoglobin Testing System

The VARIANT II TURBO Hemoglobin Testing System utilizes Bio-Rad’s HPLC precision, clinical accuracy, and offers fast throughput to enable a comprehensive solution for HbA1c testing. Results are provided in 97 seconds per sample.

Read More
Ordering Information

Overview

The VARIANT II TURBO Hemoglobin Testing System offers automation and powerful data management. Save time and minimize errors with whole blood primary tube sampling — no costly manual preparation required. Streamline workflow through continuous or batch sampling. 

Results and chromatograms are captured and archived by Bio-Rad’s Clinical Data Management (CDM) software. CDM provides remote support and interfaces with laboratory information systems (LIS) for optimal data management. 

Specifications

Dimensions (W x D x H)
VARIANT Chromatographic Station (VCS): 53.2 x 27.2 x 40.7 cm (20.9 x 10.7 x 16.0 in.)
Waste Container: 33 x 30.5 x 15.2 cm (13 x 12 x 6 in.)
VARIANT Sampling Station (VSS): 45.5 x 61.6 x 59.6 cm (17.9 x 24.3 x 23.5 in.)
Capacity
Onboard capacity: 100 sample loader (10 racks)
Time to result: 97 seconds
    Throughput:
  • 27 results per hour
  • 216 results in 8 hours
  • 648 results in 24 hours
Electrical Data
Power requirements: 100–120 VAC/200–240 VAC, 50/60 Hz
Power consumption: max. 200 VA (max. 682 BTU/hr)
Environmental Conditions
    Operating Environment:
  • Ambient temperature: 15–35°C
  • Humidity: 10–90% RH
  • Storage Conditions:
  • Temperature: −20°C to 50°C
  • Humidity: 10–95% RH
Weight (uncrated)
VARIANT Chromatographic Station (VCS): ≤35 kg (77 lb)
VARIANT Sampling Station (VSS): ≤45 kg (99 lb)  
Emissions
Product is in conformity with EN/IEC 61326-2-6

Ordering

items

Use the filters below to refine results!

Accessories

2702254
270-2149
Vials with pierceable caps for use on the VARIANT II and VARIANT II TURBO Systems, 100 x 1.5 mL
Image
dbu_196_2052_tn.jpg
196-2051

Device to collect, prepare and transport blood samples for HbA1c testing, for use with the VARIANT II and VARIANT II TURBO (5 tests)

Image
dbu_196_2052_tn.jpg
196-2052

Device to collect, prepare and transport blood samples for HbA1c testing, for use with the VARIANT II and VARIANT II TURBO (100 tests)

Image
dbu_196_2052_tn.jpg
196-2053
Prepared samples are stable for two weeks at room temperature, four weeks at 2-8° C and four days at 42° C. Samples can be analyzed immediately after blood collection. Sample volume sufficient to perform duplicate tests.
Image
dbu_196_1054_tn.jpg
196-2100
Plastic capillary tubes for use with Hemoglobin Capillary Collection System, 100 tubes per dispenser (20 dispensers)

Kits & Reagents

Controls

Image
740x_qsd_lydib_tn.jpg
740X
Assayed, lyophilized human whole blood based control for monitoring HbA1c for diabetes; MiniPak (2 x 0.5 mL)
Image
qsd_12000070_hba1c_tn.jpg
12000070
Human whole blood based control designed to verify linearity throughout the patient reportable range of HbA1c assays (6 x 0.5 mL, 1 of each level)

Documents

Number Description
Add to Cart (Free)
Add to Cart (Free)
Add to Cart (Free)