VARIANT II TURBO Hemoglobin Testing Solution
This robust, fully automated HPLC system for medium to high volume laboratories identifies HbA1c without common hemoglobin variant interferences.*
Ordering Information
Learn more
For technical specifications and ordering information for the VARIANT II TURBO System and accessories, click here.
* Interferences from common hemoglobin variants HbAS, HbAC, HbAD, and HbAE were tested. Based on net performance criteria the results were acceptable.
Explore
Automate with the VARIANT II TURBO Link Hemoglobin Testing System
Ordering Information
Improve your laboratory’s workflow with the VARIANT II TURBO Link Hemoglobin Testing System, designed to integrate the VARIANT II TURBO System with the Sysmex® XN-9000™ Automated Hematology System.
The fully automated system combines Bio-Rad's leadership in HbA1c testing with Sysmex's expertise in automation to help you be the difference for your clinicians with timely, accurate results.
-
Image
Intelligent Automation
Integration with the Sysmex® XN-9000™ Automated Hematology System provides on-demand HbA1c testing results 24/7.
-
Image
Streamlined Workflow
Sysmex® Lavender Top Management™ (LTM) Solution and Sysmex® CareSphere™ Analyzer Management (AM) provide a lean and efficient workflow.
-
Image
Unparalleled Support
All systems are backed by Bio-Rad’s world-class service and customer support.
Quality HbA1c Results
Every patient deserves quality results. You can rely on the VARIANT II TURBO System to provide clinically accurate, repeatable, gold standard HbA1c results. Other methods can potentially produce clinically inaccurate results in certain conditions.
Conditions Affecting A1c Measurement
Comparing different methods and potential for reporting clinically inaccurate results

For informational purposes only and not intended to provide medical advice or diagnosis.
* Up to 6,000 mg/dL
† Variable claims between 500 mg/dL and 3,000 mg/dL1,2
‡ A1c is not an appropriate analyte to determine glycemic status. For homozygous and double heterozygous cases, HbA is not present so there is no HbA1c to measure. Another analyte must be used to evaluate glycemic status, per the ADA guidelines.3
- Parker ML et al. (2018). HbA1c platforms are variably affected by increasing lipemia. Abstract A-288. 70th AACC Annual Scientific Meeting Abstracts.
- Mainali S et al. (2017). Frequency and causes of lipemia interference of clinical chemistry laboratory tests. Practical Laboratory Medicine 8, 1–9. https://doi.org/10.1016/j.plabm.2017.02.001.
- ADA (2022). Standards of medical care in diabetes—2022. Diabetes Care, 45 (Supplement 1), S17-S38.
Not All HbA1c Assays Are Equal
Effects of 49 Different Rare Hb Variants on HbA1c Measurement in Eight Methods
Randie R. Little et al. (2015) Journal of Diabetes Science and Technology¹
Introduction
This study examined analytical interference from 49 different less common variants comparing seven different HbA1c methods. HbA1c accuracy was assessed as well as the likelihood of the systems to report inaccurate results. The authors noted that previous studies with some assay methods have shown interference with HbA1c measurements from the four most common heterozygous Hb variants (HbAS, HbAE, HbAC, and HbAD).
Study Results
Bio-Rad HPLC systems outperformed other HbA1c testing systems. With the VARIANT II TURBO System, 97.7% clinically accurate results in the presence of rare hemoglobin variants would have been reported. The table below illustrates the clinical benefit of Bio-Rad cation-exchange HPLC for patient diagnosis and treatment.
Conclusion
To ensure accurate HbA1c results, it’s important to know whether patients have a hemoglobin variant and, if so, how that variant affects HbA1c results. Laboratories should take care when reporting results if a variant is suspected.
- Little RR et al. (2015). Effects of 49 different rare Hb variants on HbA1c measurement in eight methods. J Diabetes Sci Technol 9(4), 849-856. https://pubmedncbi.nlm.nih.gov/25691657.
Bio-Rad HPLC Reveals HbF for a Diagnosis You Can Trust
Are You Reporting Valid HbA1c Results?
HbA1c testing methods that don't see common hemoglobin variants or elevated levels of hemoglobin F might lead to misdiagnosis and unnecessary or delayed patient treatment.
Case Study Results
- Immunoassays do not reveal the presence of HbF. Clinical labs relying on immunoassays may unknowingly report incorrect results.
- The VARIANT II TURBO System reveals the presence of HbF. This allows you to confidently report HbA1c results to your clinicians.
Improve Productivity
The VARIANT II TURBO System brings speed, efficiency, and accuracy to laboratories demanding a robust system for processing thousands of tests per month.
-
Save Time and Labor
The fully automated system requires minimal maintenance and no sample preparation.
Rapid Throughput
Report HbA1c results every 97 seconds with the Clinical Data Management (CDM) software.
Release HbA1c Results Faster
Watch how the VARIANT II TURBO System simplifies HbA1c operations. It eliminates redundant, low-value tasks to release 2,500 HbA1c results faster than other HPLC systems.
Simplify Workflow
The VARIANT II TURBO Easy Release Cartridge Holder simplifies cartridge and prefilter changing.
Watch the video to learn more about the Easy Release Cartridge Holder
More Results. Less Interference.
Ordering InformationBio-Rad cation-exchange HPLC technology is the method of choice for clinicians seeking accurate results without common hemoglobin variant interference.*

Confidently report HbA1c results with the VARIANT II TURBO System
- Aids in the diagnosis of patients with diabetes
- Identifies those at risk of developing diabetes
- Monitors the progress of those living with diabetes
* Interferences from common hemoglobin variants HbAS, HbAC, HbAD, and HbAE were tested. Based on net performance criteria the results were acceptable.

VARIANT II TURBO HbA1c Kit – 2.0
HbA1c results are reportable with no interference in the presence of:
- The most common heterozygous hemoglobin variants: HbAS, HbAC, HbAD, and HbAE
- HbF ≤25%
- Carbamylated hemoglobin (CHb)
- Labile A1c (LA1c)
- Acetylated hemoglobins
- Lipemia ≤6,000 mg/dl (60g/l)
The kit is NGSP-certified, IFCC-anchored, and CE-marked