Description
Description
Bio-Plex Assay Ordering Options
Multiplex Assay Kits
Select complete kits for multiplex target panels
Singleplex Assays
Select individual target analytes of interest.
Bio-Plex Pro human diabetes immunoassays offer reliable performance and a convenient format for studying 12 markers for human diabetes and obesity.
These assays are magnetic bead–based assays, available as either premixed panels or singleplex sets, that rapidly (three hr) detect multiple diabetes and obesity biomarkers in a single experiment, using as little as 12.5 µl of sample. The 10-plex assay detects:
- C-peptide
- Ghrelin
- GIP
- GLP-1
- Glucagon
- Insulin
- Leptin
- PAI-1 (total)
- Resistin
- Visfatin
Additionally, adiponectin and adipsin can also be assayed; they are available as either singleplexes or a 2-plex. Due to different dilution schemes, these biomarkers should be assayed separately from the ten markers in the panel.
Based on 6.5 µm magnetic beads, these assays are compatible with both vacuum and magnetic wash stations. Magnetic washing simplifies plate processing, provides increased throughput, and results in decreased variability and increased reproducibility.
Key Features
- Magnetic beads for simplified plate processing
- Results obtained in 3 hr due to short 1 hr incubation time
- All-in-one, space-saving complete kit
- Premixed standards for generation of curves over a broad dynamic range for each target
Other Assay Formats Available
- Custom assays (mixed at the bench): available as Bio-Plex® Express assays
- Singleplex sets: each set includes a vial of coupled magnetic beads and a vial of detection bodies; requires a reagent kit (171304070) and a vial of standards (171D70001) for a complete assay
Instrument Compatibility
- Bio-Plex MAGPIX or Luminex MAGPIX System
- Bio-Plex 200 or Luminex 200 System
- Bio-Plex 3D or Luminex FLEXMAP 3D System
- Bio-Plex Pro Wash Stations
More Information
See how Bio-Plex instruments and assays benefit researchers studying heart disease, leukemia, melanoma, and other cancers.
Specifications
Specifications
Ordering
Ordering
items
Use the filters below to refine results!
1 x 96-well, includes conjugated magnetic beads, detection antibodies, standards, control, buffers, diluents, streptavidin-PE, flat bottom plate, sealing tape, for the detection of 10 human diabetes biomarkers
1 x 96-well, includes conjugated magnetic beads, detection antibodies, standards, control, buffers, diluents, streptavidin-PE, flat bottom plate, sealing tape, for the detection of human adiponectin and adipsin
1 x 96-well, includes conjugated magnetic beads, detection antibodies, standards, control, buffers, diluents, streptavidin-PE, flat bottom plate, sealing tape, for the detection of human adiponectin