PhD lx System

PhD lx System

The PhD lx System is an automated pipetting workstation for processing IFA slides and EIA microplates. Integrated software allows for programming custom assays.

Read More
Ordering Information

Talk with a Specialist

Overview

The PhD lx System is a versatile IFA and EIA processing system with an extensive autoimmune and infectious disease test menu. The open platform uses a modular design that enables laboratories to efficiently process low to high volume workloads and create custom assay programs.

Flexibility and Simplicity

Automate IFA and microplate EIA testing on a single analyzer.

    • Consolidate testing
    • Custom programming of IFA and EIA assays with an easy-to-use programming wizard
    • Minimize hands-on time with user-friendly IFA and EIA automation
    • Expand testing capabilities by networking multiple workstations
  • Image
    PhD lx

Efficiency

Easily switch between IFA and EIA technologies on a single instrument and network your workstations for higher throughput.

    • Cleaner IFA backgrounds with dual-probe hyper-washing
    • Bidirectional LIS (EIA) and unidirectional LIS (IFA) interface
    • Graphical user interface for intuitive programming and easy navigation
    • Minimal maintenance
  • Image
    PhD lx

PhD lx System EIA and IFA Assay Menu

Download the the PhD lx Method list here.

PhD lx IFA Menu

    • Connective Tissue Disease
    • ANCA (Anti-Neutrophil Cytoplasmic Antibody)
    • Autoimmune Liver Disease
  • Image
    PhD lx

PhD lx EIA Menu

    • Connective Tissue Disease
    • Autoimmune Liver Disease
  • Image
    PhD lx

Specifications

Dimensions
Electrical Data
Voltage: 100-240 VAC
Frequency: 50-60 Hz
Power consumption: 220 W max
Capacity
Sample capacity: EIA: 192 or IFA: 96
Microplate/slide capacity: 2 microplates/20 slides
Number of different assays on board: EIA: 8 or IFA: 4
EIA walkaway time: 1 full microplate with 3x30 incubations: 2 hr 15 min
IFA walkaway time: 96 slide wells with 2x30 incubations: 1 hr 50 min
Fluidics
Volumetric pump: Proprietary valveless ceramic design
Sample volume delivery: 1-100 μL
Maximum reagent delivery: 1000 μL
EIA incubation temperature range: up to 40°C
Precision: CV <6% for all volumes
EIA plate washing: 3 modes: normal, settable residual wash, well-by-well wash/reagent dispense
IFA slide washing: 2 modes: cycle wash and hyperwash with simultaneous dispense/aspiration
Technical Specifications
Network multiple workstations: Up to 10 PhD lx Systems can be networked through one computer, microplate reader, and LIS connection
Barcode reading: All typical symbologies, including Codabar, Code 39, Code 128, and Interleaved 2 of 5
Data reduction (interpolation): 4PL, 5PL, point-to-point, linear regression
ASTM LIS connectivity: Bi-Directional with Broadcast Download
LIS connection: Type RS-232 or TCP/IP
Microplate reader filter wavelengths: 405, 450, 550, 620 nm

Ordering

items

Use the filters below to refine results!

Image
aibu_460-0400_tn.jpg
(Discontinued) PhD lx System
426-0400

EIA and IFA processing system (110/220V), includes PhD lx Workstation with IFA and EIA hardware, computer, monitor, printer, microplate reader, barcode scanner, surge protector, and ethernet switch

Image
aibu_96an_tn.jpg
96AN
Enzyme immunoassay to screen for panel of antinuclear antibodies (ANAs) associated with systemic rheumatic diseases (96 tests)
Image
aibu_96ce_tn.jpg
96CE
Semi-quantitative enzyme immunoassay for detection of autoantibodies against the centromere antigen (96 tests)
Image
aibu_31021_tn.jpg
31021
Semi-quantitative enzyme immunoassay for detection of IgG and IgM autoantibodies specific for M2 antigen of mitochondrial membrane (96 tests)
32507
96 microplate enzyme immunoassays to detect Borrelia burgdorferi as an aid in diagnosis of Lyme disease
Image
cmd_25177_tn.jpg
(Discontinued) CMV IgG EIA Kit
25177
96 enzyme immunoassays for IgG antibodies to cytomegalovirus; this kit may not be used for avidity testing
Image
cmd_25178_tn.jpg
(Discontinued) CMV IgM EIA Kit
25178
96 enzyme immunoassays for IgM antibodies to cytomegalovirus; this kit may not be used for avidity testing
Image
cmd_25184_tn.jpg
(Discontinued) EBV VCA IgG EIA Kit
25184
96 enzyme immunoassays for IgG antibodies to viral capsid antigen of Epstein-Barr virus; to aid in diagnosis of infectious mononucleosis
Image
cmd_25183_tn.jpg
(Discontinued) EBV NA IgG EIA Kit
25183
96 enzyme immunoassays for IgG antibodies to nuclear antigen of Epstein-Barr virus; to aid in diagnosis of infectious mononucleosis
Image
cmd_25225_tn.jpg
(Discontinued) Pylori Detect IgA
25225
Qualitative enzyme immunoassay for IgA antibodies to Helicobacter pylori (96 tests)
Image
cmd_25226_tn.jpg
(Discontinued) Pylori Detect IgG
25226
Qualitative enzyme immunoassay for IgG antibodies to Helicobacter pylori (96 tests)
Image
cmd_25179_tn.jpg
25179
96 enzyme immunoassays for IgG antibodies to herpes simplex virus types 1 and 2
Image
cmd_25181_tn.jpg
(Discontinued) Measles IgG EIA Kit
25181
96 enzyme immunoassays for IgG antibodies to measles virus
Image
cmd_25182_tn.jpg
(Discontinued) Mumps IgG EIA Kit
25182
96 enzyme immunoassays for IgG antibodies to mumps virus
Image
cmd_25173_tn.jpg
(Discontinued) Rubella IgG EIA Kit
25173
96 semi-quantitative enzyme immunoassays for IgG antibodies to rubella virus
Image
cmd_25174_tn.jpg
(Discontinued) Rubella IgM EIA Kit
25174
96 semi-quantitative enzyme immunoassays for IgM antibodies to rubella virus
Image
cmd_25180_tn.jpg
(Discontinued) VZV IgG EIA Kit
25180
96 enzyme immunoassays for IgG antibodies to aid in diagnosis of primary infection with varicella zoster virus
Image
cmd_25185_tn.jpg
(Discontinued) EBV VCA IgM EIA Kit
25185
96 enzyme immunoassays for IgM antibodies to viral capsid antigen of Epstein-Barr virus; to aid in diagnosis of infectious mononucleosis

Documents

Number Description Options
Q-800
PhD lx System Brochure