Bio-Rad offers a comprehensive line of products for the blood group serology laboratory. Whether tests are performed by ID-System, microplate or conventional techniques, we provide reagents for ABO/Rh, antibody screening and identification, and antigen typing.
ID-System Menu
-
Blood Grouping ABO/D
- Combined forward and reverse grouping
- Confirmation ID-Cards for patients and/or donors
- Single or double determination of RhD
- Combined with DAT for newborn testing
- Different monoclonal antibodies for A, B and D (DVI- and DVI+)
- Specific protocols for newborn testing
-
Phenotyping Rh/K
- Different combinations, including Cw
- Rh-Subgroups + K or D
- Different monoclonal antibodies
-
Further Investigations
- Asubgroups; anti-A1, anti-H
- Typing of partial RhD
- Verification of weak D by IAT
-
Antigen Testing
- Extended antigen typing
- Antigen profiles
- Single or combined antigen testing
-
Direct Antiglobulin Test (DAT)
- With polyspecific or monospecific AHG
- Further investigations: IgG dilution and IgG subclass differentiation
- ID-Cards to assess the potential severity of a positve DAT
-
Antibody Screening
ID-Cards
- With polyspecific or monospecific AHG
- Different options available, including enzyme technique
- For type and screen
ID-Cells
- Test cells for antibody screening
- Native and enzyme treated cells
- Kits for patients and/or donors
- Expanded kit with Lua and Kpa
- Screening of maternal samples after anti-D prophylaxis
-
Antibody Identification
ID-Cards
- With polyspecific or monospecific AHG
- Combined with enzyme technique
ID-Cells
- Panel cells for antibody identification
- Additional kits for complex cases
- Native and enzyme treated cells
- Screening of maternal samples after anti-D prophylaxis
-
Compatibility Tests
- With polyspecific or monospecific AHG
- With enzyme technique
- For complete crossmatch
- Autocontrol
-
Quality Control for Blood Group Serology
- For ABO forward and/or reverse grouping, RhD and Rh/K phenotyping
- Antibody screening and identification
- Crossmatch
- DAT: Differentiation between IgG and complement; 1 cell IgG coated and 1 cell C3b(c/d) coated
- Anti-D ≤ 0.05 IU/ml standardised against the WHO 01/572 International Standard
- RhD typing: direct testing and IAT
-
Antibody Titration
ID-Cards
- LISS/Coombs (rabbit anti-IgG and monoclonal anti-C3d)
- Coombs Anti-IgG (rabbit anti-IgG)
- NaCl, Enzyme Test and Cold Agglutinins (neutral gel)
Red Blood Cells
- Native ID-Cells including reverse, screening, identification, extended panels and your own laboratory cells
-
Miscellaneous Solutions
- LISS, bromelin
- Papain
- Kit for elution
- Solution for cell freeze and thaw
- For cells stabilization suitable for ID-Cards
-
Flyers
Testing with Bio-Rad Instruments

IH-500 System
The IH-500 System combines functionality and design to meet the changing needs of the modern immunohematology laboratory by reducing hands-on time and providing faster time to results.
Learn More
IH-1000 System
The IH-1000 System is an automated blood type testing system with an on-board capacity of 240 ID-Cards. Depending on your test patterns, up to 20 different card types can be loaded at a time.
Learn MoreSolidscreen II Microplates: Protein A Solid Phase Method
Microwells coated with Protein A, high in affinity for the Fc portion of anti-human globulin, result in outstanding specificity and sensitivity.
Test Menu
- Antibody screening
- Antibody identification with or without enzyme treated cells
- Autocontrol
- Compatibility test
- Weak D typing
- Direct antiglobulin test
Improve Results While Saving Costs
Like no option on the market, the precoated microplates eliminate unnecessary antibody workups associated with other methods to reduce cost, labor and patient-care delays.
Using intact RBCs instead of RBC stroma ensures that only RBC surface antibodies are detected. This ensures minimal false positive results.
-
Reduce Labor Cost
-
Reduce False Positives
Other Advantages
- Only Anti-IgG is required, so no indicator cells are needed
- Test strips coated with Protein A instead of RBC stroma result in a stable product with a long shelf-life
- Fully-automated antibody diagnostic with TANGO infinity or semi-automatic processing of large sample runs
Erytype S Microplates: For Smart and Efficient Blood Grouping
Ready-to-use single strip trays with dried, monoclonal antisera for manual routine blood grouping or for use with the fully automated TANGO infinity system.
Test Menu
- ABO tests with or without reverse typing
- RhD determination with or without two different RhD(DVI-) antisera
- Rhesus phenotyping with or without Cw
- Kell typing
Erytype S Method for Hemagglutination Grouping — Saving Costs by Design
Like no option on the market, the precoated microplates eliminate unnecessary antibody workups associated with other methods to reduce cost, labor and patient-care delays
- Test strips with dried monoclonal antisera
- Cuts down on operator pre- and post-analytical time
- Reduces chances for antisera cross-contamination
- Use of Bromelin enhances reactivity of RBCs in the presence of corresponding antibodies
- Separation of ABO and RhD confirmatory testing on different plates reduces waste
- Anti-D confirmatory testing performed only on RhD negative donors
Testing with Bio-Rad Instruments

TANGO infinity System
The TANGO infinity system is an automated blood type testing system for use with our specially-designed microplates. The high throughput system can process up to 288 wells/hour (Erytype S microplates) and up to 133 wells/hour (Solidscreen II microplates). The table-top system stores 10 microplates for up to seven days for continuous sampling.
Traditional Immunohematology Reagents Menu
-
ABO/RhD Antisera/Rh-Phenotyping
Blood grouping by tube or slide testing
- Monoclonal antisera for all routine tube testing
- A-subgroup testing with Anti-A1 and Anti-H
- Antisera for routine RhD and D variant testing
-
Rare Antisera Monoclonal and Polyclonal for Antigen Detection
- Enhance productivity
- Minimal incubation times
- Minimal IAT assays
- Extensive line of monoclonal and polyclonal antisera
- Enhance productivity
-
Anti-Human Globulin Polyspecific and Monospecific
- AHG Anti-IgG +Anti-C3d colorless or green color
- Anti-IgG (heavy chain)
- Anti-IgM
- Anti-C3
- Anti-C3d
- Anti-C4
-
Potentiator Options
- Low ionic strength solution
- Bovine albumin
-
Specialty Products Including Supplements, Enzymes and Solutions
- Bromelin
- Papain
- IAB-Serum
- RBC stabilizer solution
-
Essential Quality Controls for Automated and Manual Testing
- IgG coated RBCs
- Whole blood quality control
- RBC quality controls in ready to use suspension
- Quality controls for antibody screening
-
Reagent RBCs for Reverse Typing
- A1, A2, B and O cells
-
Reagent RBCs for Antibody Screening
- Two cell
- Three cells (untreated and Papain treated)
- Pooled cells
- Dia positive cells
- Cord blood cells
-
Reagent RBCs for Antibody Identification
- Eight cells
- Eleven cells (untreated and Papain treated)
-
Laboratory Accessories
- Tiles
- Glass tubes
- Cover glasses
-
Further ID-Cards*
Ready to use twin ID-Cards for identity proof prior to blood transfusion
- Monoclonal antisera for ABO and ABO + RhD check
*Distribution in limited countries: Germany, France, Austria, Hungary, Slovenia, Switzerland, Belgium, Colombia, Lithuania
Download BrochureTesting with Bio-Rad Instruments

ID-Centrifuge L and ID-Incubator L
The manual test systems are uniquely designed for processing ID-Cards in addition to traditional test tubes. Both the pre-analytical and analytical centrifuge heads hold 24 ID-Cards. And the incubation head holds 36 ID-Cards.
Solutions
Matched
to Your Testing Needs
Comprehensive Selection
-
The Widest Range of IH-Cards, Red Blood Cells, and Reagents
Bio-Rad offers a comprehensive line of products for the blood bank serology laboratory. Whether tests are performed by the IH-Systems or conventional techniques, we provide reagents for ABO/Rh, antibody screening and identification, titration, and antigen typing.
IH-System Menu
-
ABO/Rh
- ABO/RhD(DVI-) (forward & reverse)
- ABO/RhD(DVI+) (forward & reverse)
- Anti-A, B x 6
- Anti-A & Anti-B x 3
- Anti-A, -B, -D(DVI+) x 2
- Anti-A, -B, -D(DVI-) x 2
- Anti-D(DVI+) x 6
- Anti-D(DVI-) x 6
- Weak D/D variant
-
Phenotyping
- Anti-C, -E, -c, -e, -K, Ctl
- Anti-C, -E, -K x 2
- Anti-C x 6
- Anti-E x 6
- Anti-c x 6
- Anti-e x 6
- Anti-K x 6
- Control x 6
- Anti-C, -E, -c, -e, -D(DVI-), Ctl
-
Antibody Identification
- 11 cell, 11 cell papain
- 6 cell supplemental panel
- Autocontrol
- Anti-IgG or Anti-IgG, -C3d
-
Crossmatching
- AHG with Anti-IgG
- AHG with Anti-IgG, -C3d
-
Newborn Card
- Anti-A, -B, -A, B, -D(DVI+), Ctl, AHG
-
Antibody Screening
- Two, Three or Pooled
- Anti-IgG or Anti-IgG, -C3dM
-
Direct AHG Test (DAT)
- Anti-IgG
- Anti-IgG, -C3d
-
Reverse Grouping
- A1,B and A2
Testing with Bio-Rad Instruments

IH-500 System
The IH-500 System combines functionality and design to meet the changing needs of the modern transfusion medicine laboratory by reducing hands-on time and providing faster time to results.
Learn More
IH-1000 System
The IH-1000 System is an automated testing system with an on-board capacity of 240 IH-Cards. Depending on your test patterns, up to 20 different card types can be loaded at a time.
Learn MoreTraditional Transfusion Medicine Reagents Menu
-
ABO/RhD Antisera
Blood grouping by tube or slide testing
- Monoclonal antisera for routine testing
- Anti-A1 lectin
- Antisera for routine RhD and D variant testing
-
Rare Antisera
- Monoclonal and polyclonal for antigen detection
- Minimal incubation times
- Minimal IAT assays
- Extensive line of monoclonal and polyclonal antisera
- Monoclonal and polyclonal for antigen detection
-
Anti-Human Globulin
Polyspecific and monospecific
- AHG Anti-IgG
- AHG Anti-IgG + Anti-C3d
-
Potentiator Options
- Low ionic strength solution
- PEG
- Albumin
-
Specialty Products
Including supplements, enzymes, and solutions
- ELUclear - eluate kit
- Diluent and preservative for gel RBC preparations
- Alsever's Solution
-
Essential Controls
For automated and manual testing
- IgG coated RBCs
- Quality Control kit
- Seraclone control
Reagent Red Blood Cells (RBCs)
For antibody detection and identification
-
Reagent RBCs for reverse screening
- A1 & B cells
- A2 cells
-
Reagent RBCs for antibody screening
- Two cell
- Three cells
- Pooled
-
Reagent RBCs for antibody indentification (panels)
- Eight cell
- Eleven cell
- Eleven cell Plus
Testing with Bio-Rad Instruments

IH-Centrifuge L and IH-Incubator L
The manual test systems are uniquely designed for processing IH-Cards in addition to traditional test tubes. The pre-analytical and analytical centrifuge heads hold 24 IH-Cards each, and the incubation head holds 36 IH-Cards.