Solutions Matched to Your
Lab Blood Testing Reagents
Enhance Productivity. Comprehensive Selection.
-
The Widest Range of ID-Cards, Red Blood Cells, and Solutions
Bio-Rad offers a comprehensive line of products for the blood group serology laboratory. Whether tests are performed by ID-System or conventional techniques, we provide reagents for ABO/Rh, antibody screening and identification, and antigen typing.
ID-System Menu
-
Blood Grouping ABO/D
- Combined forward and reverse grouping
- Confirmation ID-Cards for patients and/or donors
- Single or double determination of RhD
- Combined with DAT for newborn testing
- Different monoclonal antibodies for A, B and D (DVI- and DVI+)
- Specific protocols for newborn testing
-
Phenotyping Rh/K
- Different combinations, including Cw
- Rh-Subgroups + K or D
- Different monoclonal antibodies
-
Further Investigations
- Asubgroups; anti-A1, anti-H
- Typing of partial RhD
- Verification of weak D by IAT
-
Antigen Testing
- Extended antigen typing
- Antigen profiles
- Single or combined antigen testing
-
Direct Antiglobulin Test (DAT)
- With polyspecific or monospecific AHG
- Further investigations: IgG dilution and IgG subclass differentiation
- ID-Cards to assess the potential severity of a positve DAT
-
Antibody Screening
ID-Cards
- With polyspecific or monospecific AHG
- Different options available, including enzyme technique
- For type and screen
ID-Cells
- Test cells for antibody screening
- Native and enzyme treated cells
- Kits for patients and/or donors
- Expanded kit with Lua and Kpa
- Screening of maternal samples after anti-D prophylaxis
-
Antibody Identification
ID-Cards
- With polyspecific or monospecific AHG
- Combined with enzyme technique
ID-Cells
- Panel cells for antibody identification
- Additional kits for complex cases
- Native and enzyme treated cells
- Screening of maternal samples after anti-D prophylaxis
-
Compatibility Tests
- With polyspecific or monospecific AHG
- With enzyme technique
- For complete crossmatch
- Autocontrol
-
Quality Control for Blood Group Serology
- For ABO forward and/or reverse grouping, RhD and Rh/K phenotyping
- Antibody screening and identification
- Crossmatch
- DAT: Differentiation between IgG and complement; 1 cell IgG coated and 1 cell C3b(c/d) coated
- Anti-D ≤ 0.05 IU/ml standardised against the WHO 01/572 International Standard
- RhD typing: direct testing and IAT
-
Antibody Titration
ID-Cards
- LISS/Coombs (rabbit anti-IgG and monoclonal anti-C3d)
- Coombs Anti-IgG (rabbit anti-IgG)
- NaCl, Enzyme Test and Cold Agglutinins (neutral gel)
Red Blood Cells
- Native ID-Cells including reverse, screening, identification, extended panels and your own laboratory cells
-
Miscellaneous Solutions
- LISS, bromelin
- Papain
- Kit for elution
- Solution for cell freeze and thaw
- For cells stabilization suitable for ID-Cards
-
Flyers
Testing with Bio-Rad Instruments

IH-500 System
The IH-500 System combines functionality and design to meet the changing needs of the modern immunohematology laboratory by reducing hands-on time and providing faster time to results.
Learn More
IH-1000 System
The IH-1000 System is an automated blood type testing system with an on-board capacity of 240 ID-Cards. Depending on your test patterns, up to 20 different card types can be loaded at a time.
Learn MoreTraditional Immunohematology Reagents Menu
-
ABO/RhD Antisera/Rh-Phenotyping
Blood grouping by tube or slide testing
- Monoclonal antisera for all routine tube testing
- A-subgroup testing with Anti-A1 and Anti-H
- Antisera for routine RhD and D variant testing
-
Rare Antisera Monoclonal and Polyclonal for Antigen Detection
- Enhance productivity
- Minimal incubation times
- Minimal IAT assays
- Extensive line of monoclonal and polyclonal antisera
- Enhance productivity
-
Anti-Human Globulin Polyspecific and Monospecific
- AHG Anti-IgG +Anti-C3d colorless or green color
- Anti-IgG (heavy chain)
- Anti-IgM
- Anti-C3
- Anti-C3d
- Anti-C4
-
Potentiator Options
- Low ionic strength solution
- Bovine albumin
-
Specialty Products Including Supplements, Enzymes and Solutions
- Bromelin
- Papain
- IAB-Serum
- RBC stabilizer solution
-
Essential Quality Controls for Automated and Manual Testing
- IgG coated RBCs
- Whole blood quality control
- RBC quality controls in ready to use suspension
- Quality controls for antibody screening
-
Reagent RBCs for Reverse Typing
- A1, A2, B and O cells
-
Reagent RBCs for Antibody Screening
- Two cell
- Three cells (untreated and Papain treated)
- Pooled cells
- Dia positive cells
- Cord blood cells
-
Reagent RBCs for Antibody Identification
- Eight cells
- Eleven cells (untreated and Papain treated)
-
Laboratory Accessories
- Tiles
- Glass tubes
- Cover glasses
-
Further ID-Cards*
Ready to use twin ID-Cards for identity proof prior to blood transfusion
- Monoclonal antisera for ABO and ABO + RhD check
*Distribution in limited countries: Germany, France, Austria, Hungary, Slovenia, Switzerland, Belgium, Colombia, Lithuania
Download BrochureTesting with Bio-Rad Instruments

ID-Centrifuge L and ID-Incubator L
The manual test systems are uniquely designed for processing ID-Cards in addition to traditional test tubes. Both the pre-analytical and analytical centrifuge heads hold 24 ID-Cards. And the incubation head holds 36 ID-Cards.
Solutions Matched
to Your Testing Needs
Comprehensive Selection
-
The Widest Range of IH-Cards, Red Blood Cells, and Reagents
Bio-Rad offers a comprehensive line of products for the blood bank serology laboratory. Whether tests are performed by the IH-Systems or conventional techniques, we provide reagents for ABO/Rh, antibody screening and identification, titration, and antigen typing.
IH-System Menu
-
ABO/Rh
- ABO/RhD(DVI-) (forward & reverse)
- ABO/RhD(DVI+) (forward & reverse)
- Anti-A, B x 6
- Anti-A & Anti-B x 3
- Anti-A, -B, -D(DVI+) x 2
- Anti-A, -B, -D(DVI-) x 2
- Anti-D(DVI+) x 6
- Anti-D(DVI-) x 6
- Weak D/D variant
-
Phenotyping
- Anti-C, -E, -c, -e, -K, Ctl
- Anti-C, -E, -K x 2
- Anti-C x 6
- Anti-E x 6
- Anti-c x 6
- Anti-e x 6
- Anti-K x 6
- Control x 6
- Anti-C, -E, -c, -e, -D(DVI-), Ctl
-
Antibody Identification
- 11 cell, 11 cell papain
- 6 cell supplemental panel
- Autocontrol
- Anti-IgG or Anti-IgG, -C3d
-
Crossmatching
- AHG with Anti-IgG
- AHG with Anti-IgG, -C3d
-
Newborn Card
- Anti-A, -B, -A, B, -D(DVI+), Ctl, AHG
-
Antibody Screening
- Two, Three or Pooled
- Anti-IgG or Anti-IgG, -C3dM
-
Direct AHG Test (DAT)
- Anti-IgG
- Anti-IgG, -C3d
-
Reverse Grouping
- A1,B and A2
Testing with Bio-Rad Instruments

IH-500 System
The IH-500 System combines functionality and design to meet the changing needs of the modern transfusion medicine laboratory by reducing hands-on time and providing faster time to results.
Learn More
IH-1000 System
The IH-1000 System is an automated testing system with an on-board capacity of 240 IH-Cards. Depending on your test patterns, up to 20 different card types can be loaded at a time.
Learn MoreTraditional Transfusion Medicine Reagents Menu
-
ABO/RhD Antisera
Blood grouping by tube or slide testing
- Monoclonal antisera for routine testing
- Anti-A1 lectin
- Antisera for routine RhD and D variant testing
-
Rare Antisera
- Monoclonal and polyclonal for antigen detection
- Minimal incubation times
- Minimal IAT assays
- Extensive line of monoclonal and polyclonal antisera
- Monoclonal and polyclonal for antigen detection
-
Anti-Human Globulin
Polyspecific and monospecific
- AHG Anti-IgG
- AHG Anti-IgG + Anti-C3d
-
Potentiator Options
- Low ionic strength solution
- PEG
- Albumin
-
Specialty Products
Including supplements, enzymes, and solutions
- ELUclear - eluate kit
- Diluent and preservative for gel RBC preparations
- Alsever's Solution
-
Essential Controls
For automated and manual testing
- IgG coated RBCs
- Quality Control kit
- Seraclone control
Reagent Red Blood Cells (RBCs)
For antibody detection and identification
-
Reagent RBCs for reverse screening
- A1 & B cells
- A2 cells
-
Reagent RBCs for antibody screening
- Two cell
- Three cells
- Pooled
-
Reagent RBCs for antibody indentification (panels)
- Eight cell
- Eleven cell
- Eleven cell Plus
Testing with Bio-Rad Instruments

IH-Centrifuge L and IH-Incubator L
The manual test systems are uniquely designed for processing IH-Cards in addition to traditional test tubes. The pre-analytical and analytical centrifuge heads hold 24 IH-Cards each, and the incubation head holds 36 IH-Cards.