PrimePCR™ SYBR® Green Assay: PCBP1, Human

PrimePCR Primer Assays for Real-Time PCR oligo primer pair tube for SYBR Green gene expression

Real-time PCR primer assay designed for SYBR® Green gene expression analysis.

Info:   Same primer pair as used in probe assay qHsaCEP0057893

List Price:    $174.00
Your Price:   Log In
 
Add to Custom Plate

Assay Information

Technology:   qPCR
Assay Type:   SYBR® Green
Application:   Gene Expression
Unique Assay ID:   qHsaCED0056788
Assay Design:   exonic
Chromosome Location:   2:70315956-70316081question
Amplicon Length:   96
Splice Variants Targeted:   ENST00000303577

Gene Information

This intronless gene is thought to have been generated by retrotransposition of a fully processed PCBP-2 mRNA. This gene and PCBP-2 have paralogues (PCBP3 and PCBP4) which are thought to have arisen as a result of duplication events of entire genes. The protein encoded by this gene appears to be multifunctional. It along with PCBP-2 and hnRNPK corresponds to the major cellular poly(rC)-binding protein. It contains three K-homologous (KH) domains which may be involved in RNA binding. This encoded protein together with PCBP-2 also functions as translational coactivators of poliovirus RNA via a sequence-specific interaction with stem-loop IV of the IRES and promote poliovirus RNA replication by binding to its 5'-terminal cloverleaf structure. It has also been implicated in translational control of the 15-lipoxygenase mRNA human Papillomavirus type 16 L2 mRNA and hepatitis A virus RNA. The encoded protein is also suggested to play a part in formation of a sequence-specific alpha-globin mRNP complex which is associated with alpha-globin mRNA stability. [provided by RefSeq Jul 2008]

Gene Symbol:   PCBP1
Gene Name:   poly(rC) binding protein 1
Aliases:   HNRPE1, HNRPX, hnRNP-E1, hnRNP-X
RefSeq:   NC_000002.11 NT_022184.15
Ensembl:   ENSG00000169564
Entrez:   5093
Chromosome Mapping:   2p13-p12

The below validation information is for the Primer Pair only   Download Validation Data (.pdf)


Products used to generate validation data:

Real-Time PCR Instrument CFX384 Real-Time PCR Detection System
Reverse Transcription Reagent iScript™ Advanced cDNA Synthesis Kit for RT-qPCR
Real-Time PCR Supermix SsoAdvanced™ Universal SYBR® Green Supermix
Experimental Sample qPCR Human Reference Total RNA

Summary Data:

R2 0.999700
y-intercept 35.900000
Efficiency 97

Amplification Plot
Amplification of cDNA generated from universal RNA.

Amplification of cDNA generated from universal RNA.

Melt Peak
Melt curve analysis of above amplification.

Melt curve analysis of above amplification.

Standard Curve
Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Number Description Download
10039761 PrimePCR™ Assays Quick Guide, Ver B Click to download