Description
Description
Questions? Ask a Bio-Plex Specialist.
Bio-Plex SARS-CoV-2 Neutralization Antibody Assays Webinar
Use the SARS-CoV-2 Neutralization Antibody Reagent Kit when performing Bio-Plex Pro Singleplex or Multiplexed Neutralization Antibody Assays with Bio-Plex SARS-CoV-2 RBD, S1, Alpha S1, Beta S1, Gamma RBD, D614G S1, E484K RBD, Epsilon RBD, K417N RBD, Kappa RBD, N501Y RBD, Delta RBD and Spike Trimer 2-Plex antigens, viral antigens coupled magnetic beads and the Bio-Plex Pro Biotinylated Detection ACE2 Receptor, and Bio-Plex Pro SARS-CoV-2 Neutralization Antibody Standard.
Kit Components for Running Human Samples
- Human serology sample diluent
- Assay buffer
- Wash buffer
- Streptavidin-PE
- Flat-bottom plate
- Sealing tape
Assay Compatibility
The Bio-Plex Pro SARS-CoV-2 Neutralization Antibody Reagent Kit (12017037) is compatible with the following assay components:
- Bio-Plex Pro SARS-CoV-2 Receptor-Binding Domain Coupled Beads (12015406)
- Bio-Plex Pro SARS-CoV-2 Spike 1 Coupled Beads (12014771)
- Bio-Plex Pro SARS-CoV-2 Alpha S1 Coupled Beads (12016868)
- Bio-Plex Pro SARS-CoV-2 Beta S1 Coupled Beads (12016849)
- Bio-Plex Pro SARS-CoV-2 Gamma RBD Coupled Beads (12016898)
- Bio-Plex Pro SARS-CoV-2 D614G S1 Coupled Beads (12016838)
- Bio-Plex Pro SARS-CoV-2 Delta RBD and Spike Trimer 2-Plex Coupled Beads (12017225)
- Bio-Plex Pro SARS-CoV-2 E484K RBD Coupled Beads (12016943)
- Bio-Plex Pro SARS-CoV-2 Epsilon RBD Coupled Beads (12016875)
- Bio-Plex Pro SARS-CoV-2 K417N RBD Coupled Beads (12016942)
- Bio-Plex Pro SARS-CoV-2 Kappa RBD Coupled (12016850)
- Bio-Plex Pro SARS-CoV-2 N501Y RBD Coupled Beads (12016869)
- Bio-Plex Pro SARS-CoV-2 Neutralization Antibody Standard (12016945)
- Bio-Plex Pro Biotinylated Detection ACE2 Receptor (12016944)
Browse all Bio-Plex SARS-CoV-2 Neutralization Antibody Assays and Components.
Instrument Compatibility
- Bio-Plex MAGPIX or Luminex MAGPIX System
- Bio-Plex 200 or Luminex 200 System
- Bio-Plex 3D or Luminex FLEXMAP 3D
- Luminex INTELLIFLEX System
- Bio-Plex Pro Wash Station
Specifications
Specifications
Documents
Documents
Recommended SKUs
Recommended SKUs
1 x 96-well, biotinylated detection ACE2 receptor. The SARS-CoV-2 spike protein binds to the ACE2 receptor during viral entry. Requires Bio-Plex Pro Neutralization Reagent Kit, Bio-Plex Pro Neutralization Antibody Standard, and Bio-Plex Pro SARS-CoV-2 Antigen Coupled Beads to run a complete singleplex or multiplex assay.
Pkg of 1 vial, Neutralization Antibody Standard binds to SARS-CoV-2 viral antigens, enough to generate a standard curve in duplicate for 1 x 96 well plate; for use with Bio-Plex Pro SARS-CoV-2 Antigen Coupled Beads, Bio-Plex Pro Biotinylated Detection ACE2 Receptor, Bio-Plex Pro SARS-CoV-2 Neutralization Antibody Reagent Kit.