Liquid Assayed Multiqual is an assayed, liquid, human serum-based control that is intended to be a general chemistry control for testing serum chemistry analytes. This consolidated quality control provides a comprehensive set of more than 80 general chemistry analytes, designed to maximize testing efficiency for integrated and modular platforms in today’s modern core laboratory.

The control is available in two configurations, a standard vial and a compact vial with barcode. The compact vial is compatible with applicable automated platforms such as Siemens Dimension Vista and Abbott Alinity while the 2D barcode allows for quick and easy QC setup. The control is available in three levels. Multiple levels of a control allow monitoring of test system reliability.

 

Order Online—Reserve Your Lots Today

QC Lot reservation and schedule delivery—Now available with online ordering.

Login or Register on My Bio-Rad today and start ordering and reserving »

 

Features

  • Multiple configurations—Compact vial offers ready-to-use convenience, eliminating handling errors
  • Consolidated menu of analytes—Contains more than 80 analytes for monitoring routine chemistry assays
  • Patient-like material—Liquid, human serum-based control
  • Multiple levels—Trilevel control offers increased assay range monitoring
  • Extensive value assignment listings—Allows for use of a wide range of testing methods on most major integrated and modular platforms to help consolidate and streamline workflows
  • Long shelf life—Reduces crossover studies which helps simplify workflow

 

Storage & Stability

Configuration Stability Shelf life Levels Format
3 mL • 3 year shelf life at -20°C to -70°C
• 30 day unopened stability at 2-8ºC for most analytes
• 14 day open-vial stability at 2-8ºC for most analytes
3 years at -20°C to -70°C 1, 2, 3 & Trilevel MiniPak Standard vial
2.5 mL • 5 day open-vial stability for all analytes when stored at 2-8ºC
• 3 year shelf life when stored at -20ºC to -50ºC
3 years at -20°C to -50°C 1, 2, 3 & Trilevel MiniPak Compact vial

 

Analytes

    • Acetaminophen
    • Acid Phosphatase (Total)*
    • Albumin
    • Albumin: Globulin Ratio*
    • Alpha-1-Antitrypsin
    • Alkaline Phosphatase
    • Alpha-HBDH*1
    • ALT/SGPT
    • Amikacin*
    • Amylase
    • Amylase (Pancreatic)*
    • Apolipoprotein A-I
    • Apolipoprotein B
    • AST/SGOT
    • Bilirubin (Direct)
    • Bilirubin (Neonatal)*
    • Bilirubin (Total)
    • Calcium (Ionized)*
    • Calcium
    • Carbamazepine
    • Ceruloplasmin
    • Chloride
    • Cholesterol (HDL)
    • Cholesterol (LDL)
    • Cholesterol (Total)
    • Cholinesterase
    • CK-MB Isoenzyme*1
    • Carbon Dioxide (CO2)
    • Complement C3
    • Complement C4
    • Copper*
    • Cortisol*
    • Creatine Kinase (CK)
    • Creatinine
    • Digoxin
    • Ethanol
    • Ferritin
    • Gamma Glutamyltransferase (GGT)
    • Gentamicin
    • Globulin (Alpha-1)*
    • Globulin (Alpha-2)*
    • Globulin (Beta)*
    • Globulin (Gamma)*
    • Glucose
    • Haptoglobin
    • Immunoglobulin A (IgA)
    • Immunoglobulin G (IgG)
    • Immunoglobulin M (IgM)
    • Iron
    • Iron (TIBC)
    • Iron (UIBC)*
    • Lactate (Lactic Acid)
    • Lactate Dehydrogenase (LDH)
    • LAP Arylamidase*
    • Lipase
    • Lithium
    • Magnesium
    • Osmolality*
    • Prostatic Acid Phosphatase (PAP)*
    • Phenobarbital
    • Phenytoin
    • Phospholipids*
    • Phosphorus
    • Potassium
    • Prealbumin
    • Protein Serum (Total)
    • Salicylate
    • Sodium
    • T3 (Total)
    • T3 Uptake/T Uptake
    • T4 (Free)
    • T4 (Total)
    • Theophylline
    • Thyroid Stimulating Hormone (TSH)
    • Tobramycin
    • Transferrin
    • Triglycerides
    • Urea*
    • Urea Nitrogen (BUN)
    • Uric Acid
    • Valproic Acid
    • Vitamin B12
    • Zinc*

*Not included in compact vial format.
No claim is made for expected value or stability.

Refer to My eInserts or the product insert (IFU) of currently available lots for specific analyte and stability claims.

 

Related Products

InteliQ Assayed Multiqual Control
InteliQ Controls 
Therapeutic Drug Monitoring Controls 
Urine Chemistry Controls

 

Frequently Asked Questions

After use, how long can the control product be left out before return to refrigerator?
Typically, if the product has been stored refrigerated, allow the product to reach room temperature (18°C to 25°C) before use (specific time limitations may apply, depending on the product). For optimal analyte stability, promptly return the product to the recommended storage temperature after each use.
What type of water should be used to reconstitute lyophilized control products?
Typically, distilled or deionized water is used. Please refer to the product insert (IFU) for product specific reconstitution instructions.
How long should the reconstituted control remain at room temperature prior to use?
Upon reconstitution, the stopper should be replaced and the product should be allowed to stand at room temperature for the time period indicated in the package insert. Prior to use, gently swirl the vial to ensure homogeneity. Refer to the procedure section of the product insert (IFU) for product-specific handling instructions.
How long should frozen liquid controls sit at room temperature in order to thaw?
Typically, the frozen product should be allowed to thaw at room temperature (18°C to 25°C) for the time indicated in the product insert (IFU) or until completely thawed prior to use. The product vial should be swirled gently to ensure homogeneity prior to use. Refer to the procedure section of the product insert (IFU) for product-specific handling instruction.
What are the acceptable limits for room, refrigerator, and freezer temperature?
This information is stated in the product insert (IFU):
  • Room temperature: 18°C to 25°C
  • Refrigerator temperature: 2-8°C
  • Freezer temperature: -20°C to -70°C/-20°C to -50°C for 2.5 mL vial

Most frozen products recommend avoidance of frost-free freezers. There are exceptions, so refer to specific control insert.

Ordering

Ordering

items

Use the filters below to refine results!

Image
695x_qsd_asymq_tn.jpg
695X
Assayed, liquid human serum based comprehensive chemistry control with 80 analytes; trilevel MiniPak (3 x 3 mL)
Image
337_qsd_asymqvista_tn.jpg
337

Assayed, liquid human serum based comprehensive chemistry control with over 60 analytes. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity; level 1 of 3 (12 x 2.5 mL)

Image
338_qsd_asymqvista_tn.jpg
338

Assayed, liquid human serum based comprehensive chemistry control with over 60 analytes. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity; level 2 of 3 (12 x 2.5 mL)

Image
339_qsd_asymqvista_tn.jpg
339

Assayed, liquid human serum based comprehensive chemistry control with over 60 analytes. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity; level 3 of 3 (12 x 2.5 mL)

Image
338X_qsd_asymqvista_tn.jpg
338X

Assayed, liquid human serum based comprehensive chemistry control with over 60 analytes. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity; trilevel MiniPak (3 x 2.5 mL)

Accessories

Accessories

Image
qsd_98700_tip_screwcap_tn.jpg
987000
Disposable plastic tip accessories for quality controls fitted with a screw cap closure. Enables fluid delivery directly from glass vial. 100/Package.

Documents

Documents

Number Description Options
Q-1214
Bio-Rad Quality Control Products in Compact Vials
[ Add to Cart (Free) ]
Q-1118
Quality Control Products & Services Catalog
[ Add to Cart (Free) ]