Assay Information

Technology:   qPCR
Assay Type:   Probe
Application:   Gene Expression
Unique Assay ID:   qHsaCIP0028730
Assay Design:   Intron-spanning
Chromosome Location:   19:16275607-16279007question
Amplicon Length:   148
Splice Variants Targeted:   ENST00000269878 ENST00000379859

Gene Information

This gene product shares a high degree of sequence similarity with DNA-dependent protein kinase catalytic subunit-interacting protein 2 in human and mouse and like them may bind the catalytic subunit of DNA-dependent protein kinases. The exact function of this gene is not known. [provided by RefSeq Jul 2008]

Gene Symbol:   CIB3
Gene Name:   calcium and integrin binding family member 3
Aliases:   KIP3, MGC138405, MGC142151, MGC96922
RefSeq:   NC_000019.9 NT_011295.11
Ensembl:   ENSG00000141977
Entrez:   117286
UniGene:   Hs.255432
Chromosome Mapping:   19p13.12

The below validation information is for the Primer Pair only   Download Validation Data (.pdf)


Products used to generate validation data:

Real-Time PCR Instrument CFX384 Real-Time PCR Detection System
Reverse Transcription Reagent iScript™ Advanced cDNA Synthesis Kit for RT-qPCR
Real-Time PCR Supermix SsoAdvanced™ SYBR® Green Supermix
Experimental Sample qPCR Human Reference Total RNA

Summary Data:

R2 0.998700
y-intercept 35.490000
Efficiency 95

Amplification Plot
Amplification of cDNA generated from universal RNA.

Amplification of cDNA generated from universal RNA.

Melt Peak
Melt curve analysis of above amplification.

Melt curve analysis of above amplification.

Standard Curve
Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.