PrimePCR™ Probe Assay: USF1, Human

RT

Real-time PCR probe assay designed for gene expression analysis. Probe assays consist of unlabeled PCR primers and a dual labeled fluorescent probe.

List Price:    $255.00
Your Price:   Log In
 

Assay Information

Technology:   qPCR
Assay Type:   Probe
Application:   Gene Expression
Unique Assay ID:   qHsaCEP0053091
Assay Design:   exonic
Chromosome Location:   1:161009789-161010102question
Amplicon Length:   92
Splice Variants Targeted:   ENST00000262304 ENST00000423118 ENST00000567946 ENST00000368020 ENST00000368021 ENST00000368019 ENST00000528768 ENST00000531842 ENST00000435396 ENST00000372600 ENST00000372599 ENST00000259324

Gene Information

This gene encodes a member of the basic helix-loop-helix leucine zipper family and can function as a cellular transcription factor. The encoded protein can activate transcription through pyrimidine-rich initiator (Inr) elements and E-box motifs. This gene has been linked to familial combined hyperlipidemia (FCHL). Two transcript variants encoding distinct isoforms have been identified for this gene. [provided by RefSeq Jul 2008]

Gene Symbol:   USF1
Gene Name:   upstream transcription factor 1
Aliases:   FCHL, FCHL1, HYPLIP1, MLTF, MLTFI, UEF, bHLHb11
RefSeq:   NC_000001.10 NG_011612.1 NT_004487.19
Ensembl:   ENSG00000158773
Entrez:   7391
Chromosome Mapping:   1q22-q23

The below validation information is for the Primer Pair only   Download Validation Data (.pdf)


Products used to generate validation data:

Real-Time PCR Instrument CFX384 Real-Time PCR Detection System
Reverse Transcription Reagent iScript™ Advanced cDNA Synthesis Kit for RT-qPCR
Real-Time PCR Supermix SsoAdvanced™ Universal SYBR® Green Supermix
Experimental Sample qPCR Human Reference Total RNA

Summary Data:

R2 0.999900
y-intercept 36.540000
Efficiency 94

Amplification Plot
Amplification of cDNA generated from universal RNA.

Amplification of cDNA generated from universal RNA.

Melt Peak
Melt curve analysis of above amplification.

Melt curve analysis of above amplification.

Standard Curve
Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Number Description Download
10039761 PrimePCR™ Assays Quick Guide, Ver B Click to download
10042030 PrimePCR™ PreAmp Assay Quick Guide, Rev A Click to download
10000088666 Instruction Manual, PrimePCR Assays, Panels, and Controls, Ver G Click to download
10000143205 SARS-CoV-2 Variant Detection RT-PCR Assay Protocol Click to download
3226 PIS_PrimePCR SARS-CoV-2 Single and Multiple Mutation Assays Click to download
10000147102 PrimePCR SARS-CoV-2 Multiple Mutation Assay Protocol Click to download