PrimePCR™ SYBR® Green Assay: MRVI1, Human

PrimePCR Primer Assays for Real-Time PCR oligo primer pair tube for SYBR Green gene expression

Real-time PCR primer assay designed for SYBR® Green gene expression analysis.

Info:   Recommended - best coverage; Same primer pair as used in probe assay qHsaCEP0049592

List Price:    $174.00
Your Price:   Log In
 
Add to Custom Plate

Assay Information

Technology:   qPCR
Assay Type:   SYBR® Green
Application:   Gene Expression
Unique Assay ID:   qHsaCED0042329
Assay Design:   exonic
Chromosome Location:   11:10598030-10602021question
Amplicon Length:   83
Splice Variants Targeted:   ENST00000423302 ENST00000558540 ENST00000541483 ENST00000531107 ENST00000527509 ENST00000534266 ENST00000421747 ENST00000436272 ENST00000547195 ENST00000552103 ENST00000545852 ENST00000424001

Gene Information

This gene is similar to a putative mouse tumor suppressor gene (Mrvi1) that is frequently disrupted by mouse AIDS-related virus (MRV). The encoded protein which is found in the membrane of the endoplasmic reticulum is similar to Jaw1 a lymphoid-restricted protein whose expression is down-regulated during lymphoid differentiation. This protein is a substrate of cGMP-dependent kinase-1 (PKG1) that can function as a regulator of IP3-induced calcium release. Studies in mouse suggest that MRV integration at Mrvi1 induces myeloid leukemia by altering the expression of a gene important for myeloid cell growth and/or differentiation and thus this gene may function as a myeloid leukemia tumor suppressor gene. Several alternatively spliced transcript variants encoding different isoforms have been found for this gene and alternative translation start sites including a non-AUG (CUG) start site are used. [provided by RefSeq May 2011]

Gene Symbol:   MRVI1
Gene Name:   murine retrovirus integration site 1 homolog
Aliases:   IRAG, JAW1L
RefSeq:   NC_000011.9 NT_009237.18
Ensembl:   ENSG00000072952
Entrez:   10335
Chromosome Mapping:   11p15

The below validation information is for the Primer Pair only   Download Validation Data (.pdf)


Products used to generate validation data:

Real-Time PCR Instrument CFX384 Real-Time PCR Detection System
Reverse Transcription Reagent iScript™ Advanced cDNA Synthesis Kit for RT-qPCR
Real-Time PCR Supermix SsoAdvanced™ Universal SYBR® Green Supermix
Experimental Sample qPCR Human Reference Total RNA

Summary Data:

R2 0.999400
y-intercept 35.580000
Efficiency 100

Amplification Plot
Amplification of cDNA generated from universal RNA.

Amplification of cDNA generated from universal RNA.

Melt Peak
Melt curve analysis of above amplification.

Melt curve analysis of above amplification.

Standard Curve
Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Number Description Download
10039761 PrimePCR™ Assays Quick Guide, Ver B Click to download