Technology:   qPCR
Assay Type:   SYBR® Green
Application:   Gene Expression
Unique Assay ID:   qHsaCED0037323
Assay Design:   exonic
Chromosome Location:   6:31604024-31604171question
Amplicon Length:   118
Splice Variants Targeted:   ENST00000430737 ENST00000422962 ENST00000547669 ENST00000549768 ENST00000458561 ENST00000414956 ENST00000547056 ENST00000549383 ENST00000376007 ENST00000376033 ENST00000454306 ENST00000432252 ENST00000550609 ENST00000550109 ENST00000439762 ENST00000416335 ENST00000550674 ENST00000548373 ENST00000435971 ENST00000428775 ENST00000551794 ENST00000549037 ENST00000383464 ENST00000383455 ENST00000551341 ENST00000547457

Gene Information

A cluster of genes BAT1-BAT5 has been localized in the vicinity of the genes for TNF alpha and TNF beta. These genes are all within the human major histocompatibility complex class III region. This gene has microsatellite repeats which are associated with the age-at-onset of insulin-dependent diabetes mellitus (IDDM) and possibly thought to be involved with the inflammatory process of pancreatic beta-cell destruction during the development of IDDM. This gene is also a candidate gene for the development of rheumatoid arthritis. Two transcript variants encoding the same protein have been found for this gene. [provided by RefSeq Dec 2010]

Gene Symbol:   PRRC2A
Gene Name:   proline-rich coiled-coil 2A
Aliases:   BAT2, D6S51, D6S51E, DKFZp686D09175, G2
RefSeq:   NC_000006.11 NT_007592.15 NT_113891.2 NT_167245.1 NT_167246.1 NT_167247.1 NT_167248.1 NT_167249.1
Ensembl:   ENSG00000204469
Entrez:   7916
Chromosome Mapping:   6p21.3

The below validation information is for the Primer Pair only   Download Validation Data (.pdf)


Products used to generate validation data:

Real-Time PCR Instrument CFX384 Real-Time PCR Detection System
Reverse Transcription Reagent iScript™ Advanced cDNA Synthesis Kit for RT-qPCR
Real-Time PCR Supermix SsoAdvanced™ SYBR® Green Supermix
Experimental Sample qPCR Human Reference Total RNA

Summary Data:

R2 0.999700
y-intercept 35.660000
Efficiency 96

Amplification Plot
Amplification of cDNA generated from universal RNA.

Amplification of cDNA generated from universal RNA.

Melt Peak
Melt curve analysis of above amplification.

Melt curve analysis of above amplification.

Standard Curve
Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Number Description Download
10039761 PrimePCR™ Assays Quick Guide, Ver B Click to download