Using the TC20™ Automated Cell Counter
Cell Size Gating — Counting Primary Cells and Other Complex Samples

The TC20™ automated cell counter has two counting modes. Depending on the sample type, the user-defined gates can be either enabled or disabled.

Samples with Multiple Cell Populations (stem cells and other primary cells)

User-defined gates must be enabled. Once the user-defined gates are enabled, a histogram will be displayed at the beginning of each count and the user can select the population of interest by adjusting the position of the cell size gates. Only objects within the designated range will be analyzed as cells; those with diameters outside of the size range will be excluded from the cell count.

If the user-defined gates are disabled, the cell counting algorithm will automatically determine the population to count without any user input. The algorithm will count the cells of the most predominate cell type that typically comprise the largest peak, which may not be the population the user wants to count.


 
Gating setup window. Cell size gating window.

To make counting of such samples easier, when counting multiple sample replicates, the TC20 cell counter can save the positions of gates and apply them to subsequent counts (choose Yes in the “Use saved gates” field in Gating setup).

If the Image preview is On, an image of cells will be displayed during gating. In the image, only cells with diameters between the selected size gates will be marked with a yellow dot.

Immortal Cell Lines

When counting immortal cell lines or other samples that are composed of cells with similar cell size, the user-defined gates can be disabled. The cell counting algorithm then automatically identifies the cell population of interest without requiring user input.

Cells Counted with the TC20™ Automated Cell Counter

The TC20 automated cell counter can accurately count a broad range of cell types:

  • Immortal cell lines
  • Primary cells from tissue or blood (peripheral blood mononuclear cells, primary lymphocytes)
  • Stem cells

The TC20 counter can count cells with a round shape after trypsinization and a cell diameter between 6 and 50 µm.

These cells were counted using the TC20 automated cell counter either by Bio-Rad scientists or customers. If you do not find your cell name in this list, please contact us at 1-800-424-6723 (Technical Support).


Cells Counted with the TC20 Automated Cell Counter

Launch the Gallery

Performance Data

The data below show the TC20™ automated cell counter is compatible with a broad range of cell types, such as cell lines, primary cells (from tissue or blood), and stem cells. The TC20 cell counter can count cells with a 6–50 µm cell diameter and within a broad concentration range of 5 x 104–1 x 107 cells/ml, which eliminates the need to dilute cells, thus reducing the error associated with sample dilutions prior to counting.

The TC20 automated cell counter demonstrates accurate cell counts across a range of cell sizes. Small (PBMC, Jurkat), medium (HeLa), and large (MEF) cells were counted with a hemocytometer, a TC20 automated cell counter, and a competitor's image-based automated cell counter. The TC20 counter and hemocytometer cell counts showed no statistically significant differences. Precision is indicated by the standard deviations; error bars represent average standard deviations. Cell counts on the TC20 counter were performed on one instrument with four sample replicates.


The TC20 automated cell counter demonstrates accurate counts of viable cells. Pan T cells mixed with trypan blue (1:1) were counted with a hemocytometer, a TC20 automated cell counter, and a competitor’s image-based automated cell counter. The TC20 counter and hemocytometer cell counts showed no statistically significant differences. Precision is indicated by the standard deviations; error bars represent average standard deviations. Cell counts on the TC20 counter were performed on four different instruments with five sample replicates.
Determining Cell Viability Using Multifocal Plane Analysis

The TC20™ automated cell counter uses microscopy with auto-focus that analyzes multiple focal planes to identify the best plane. The cell counting algorithm then uses the image acquired from the best focal plane to identify cells and exclude debris, thereby calculating the total cell count.

Using auto-focus instead of subjective manual focusing is especially important when assessing cell viability because an incorrectly selected focal plane will lead to inaccurate results.

If trypan blue is detected along with the total cell count, the TC20 counter assesses cell viability. The conventional method of analyzing viability using a single focal plane can lead to inaccurate conclusions because light scattering and the alignment of cells at different heights in a counting chamber can change the appearance of cells — live cells may appear to be dead and vice versa. To determine if cells are viable, the TC20 counter analyzes each cell using images acquired from multiple focal planes during the focusing step.

Effect of multifocal plane analysis on live/dead count accuracy for HeLa cells.
Viability Assessment Live Cells, % Dead Cells, %
Single best focal plane* 35 65
Multiple focal planes* 65 35
* On single focal plane, 35% of live cells were misidentified as dead cells.

 

Data Analysis and Management

View, Export, and Analyze Your Data

After viewing cell count results, users can choose to view an image of the counted cells on the TC20™ automated cell counter with the ability to zoom in on an image with the click of a button.



 


After a count, a JPEG file of the cell image is available for immediate export to a USB flash drive or, to save every cell image, automatic data export can be enabled. Each cell image contains a metatag with the count data and can be further analyzed using TC20 data analyzer software. This optional software can be used to review single images, perform multi-file comparative analyses, and generate reports.




 


Results from 100 counts are stored in the TC20 cell counter so you can always go back and recover counts based on their acquisition date and time stamp. Previous count results can be exported via the USB port and opened in a Microsoft Excel spreadsheet, allowing easy comparison of results between experiments.




 


You can assign a custom sample name that will be associated with the count result and the JPEG image. To save time when working with multiple sample replicates, enable the automatic name serialization option to populate numerically serialized names.




 


The optional thermal label printer can be connected to the TC20 counter to print results onto labels that can be placed into a laboratory notebook for traceability of the count results.




 


Users can access the onboard dilution calculator to determine volume adjustments required to achieve the cell concentration needed for the next experiment.




Cell Biology 101

 

Mammalian tissue or cell culture techniques were developed in the early 1900s as a method of maintaining animal organs outside of the body. During the 1940s and 1950s cell culture technology emerged as an essential tool to support virology research by enabling vaccine production through viral purification. Today, cell culture is used worldwide as a model for a variety of studies, including intra- and intercellular communication, tissue/organ development or organization, and different disease states, such as cancer, Parkinson's disease, and diabetes.

In this guide the most common cell types used in cell biology are described.

  Cell Biology 101

 

Basic Cell Culture Introduction

 

Mammalian tissue or cell culture techniques were developed in the early 1900s as a method of maintaining animal organs outside of the body. During the 1940s and 1950s cell culture technology emerged as an essential tool to support virology research by enabling vaccine production through viral purification. Today, cell culture is used worldwide as a model for a variety of studies, including intra- and intercellular communication, tissue/organ development or organization, and different disease states, such as cancer, Parkinson's disease, and diabetes.

This presentation provides an introduction to growing and maintaining mammalian cells in culture.

 

  Basic Cell Culture Introduction

 

Scroll upScroll down


The TC20 automated cell counter counts mammalian cells in one simple step using its innovative auto-focus technology and sophisticated cell counting algorithm to produce accurate cell counts in less than 30 seconds. Upon insertion of a counting slide, the TC20 cell counter rapidly provides a total cell count (with or without trypan blue staining) and assesses cell viability via trypan blue exclusion..

Key Features and Benefits

  • Compatible with a broad range of cell sizes and types — counts cell lines, primary cells (from tissue or blood), and stem cells
  • Innovative auto-focus technology — removes the variation associated with manual focusing and leads to precise cell counts in 30 seconds
  • Cell size gates — user selects a population of interest in complex samples, such as primary cells, or lets the cell counting algorithm do all the work
  • Cell viability — analyzes cells accurately using multifocal plane analysis
  • Easy to archive and analyze — stores up to 100 counts in the onboard memory for access any time, or use the optional TC20 data analyzer software on your PC to further analyze exported cell images

Getting all the data you need about your cell cultures is fast and easy; the TC20 cell counter and disposable counting slides eliminate the need for tedious setup, cleaning, or maintenance. The TC20 cell counter is simple and intuitive to use — learn to use the TC20 automated cell counter in the introduction video or take a virtual test drive.

 

Load Insert View results
Load the sample onto a slide. Insert the slide into the TC20 cell counter; counting automatically begins. Obtain a total cell count (without trypan blue) or total and live cell counts (with trypan blue) in 30 seconds.

 

The TC20 automated cell counter has replaced the TC10™ automated cell counter. If you own the TC10 automated cell counter, please visit the Accessories tab on this page to order additional kits, reagents, and accessories for your ongoing work using the TC10 cell counter. Please note that all accessories are compatible with both the TC20 and TC10 automated cell counters.

Get Accurate and Reproducible Results

The TC20 automated cell counter uses microscopy with auto-focus that analyzes multiple focal planes to identify the best plane. Without requiring any user input, the sophisticated cell counting algorithm uses the image acquired from the best focal plane to identify cells and exclude debris, thereby calculating the total cell count. The auto-focus leads to highly reproducible cell counts with reduced user-to-user variability compared to a hemocytometer and cell counters with manual focus. Using auto-focus instead of subjective manual focusing is especially important when assessing cell viability because an incorrectly selected focal plane will lead to inaccurate results.

Unlike cell counters based on electrical impedance (Coulter principle), the TC20 image-based analysis allows the user to view the cells in real time, providing visual proof that the TC20 cell counter has correctly identified cells.

The TC20 automated cell counter provides accuracy comparable to results obtained with a hemocytometer. It can count cells with a 6–50 μm cell diameter and within a broad concentration range of 5 x 104–1 x 107 cells/ml, which eliminates the need to dilute cells, thus reducing errors associated with sample dilutions prior to counting. Read more about how the TC20 compares to a hemocytometer.

This automated counter uses disposable counting slides with a patent-pending design that ensures even distribution of cells throughout the counting chamber, regardless of the user's pipetting style, allowing every user to accurately and consistently count cells.

For complex samples composed of multiple cell populations, such as primary cells, users can adjust the cell size gates to define the population of interest that will be counted. When counting multiple sample replicates, the TC20 automated cell counter can save the position of the cell size gates and apply them to subsequent counts.

When user-defined gates are enabled you can select a population of interest by adjusting the position of the cell size gates.

Cell Viability

The TC20 automated cell counter uses multifocal plane analysis to assess cell viability. The conventional method of analyzing viability using a single focal plane can lead to inaccurate conclusions because light scattering and the alignment of cells at different heights in a counting chamber can change the appearance of cells — live cells may appear to be dead and vice versa. To determine whether cells are viable, the TC20 counter analyzes each cell using images acquired from multiple focal planes during the focusing step. Find out more about the advantages of multifocal plane analysis.

Minimize Your Sample Preparation

The broad concentration range of the TC20 automated cell counter eliminates the need to dilute cells prior to counting, reducing the errors associated with sample dilutions that may be necessary when counting cells by other methods. The counting algorithm discriminates and counts individual cells within clusters of up to five cells, providing accurate counts without the need to extensively declump cells prior to loading.

Counting time, sec 30
Cell concentration range, cells/ml 5 x 104–1 x 107
Optimal cell concentration range, cells/ml 1 x 105–5 x 106
Cell diameter range, µm 6–50
Sample volume, µl 10
Data storage, counts 100
Data export Via USB flash drive
Printer connectivity Yes
Dilution calculator Yes
Image of cells available Yes
Dimensions (W x D x H), cm (in) 19 x 15 x 25.4 (7.5 x 6 x 10)
Weight without the external power supply, kg (lb) 2.2 (4.8)
x

Account price failed to display. Please try reloading the page.Reload Page

If you are placing an order, you may proceed with your order; the account price will be applied if it is lower than the
list price. If the problem persists, please call customer service at or send an
email to

Cell Counting Kit, 30 dual-chambered slides, 60 counts, with trypan blue

1450003
30 slide pack of dual-chamber slides (60 counts), includes 1.5 ml trypan blue, for use with TC10™ or TC20™ automated cell counter

1450003 /templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0003_1272584432.xml 1450003 /default/main/bio-rad/WORKAREA/default 04/29/10 04:38 PM en_US juso9mv6 2018-02-01 00:54:49 true true internet/product_SKU juso9mv6 templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0003_1272584432.xml LSR 2019-05-04 16:25:19 /default/main/bio-rad/STAGING N /default/main/bio-rad en 04/29/20 04:40 PM 1556044787683 AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA,VN 2019-05-04 16:25:19 /default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0003_1272584432.xml templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0003_1272584432.xml 1450003-cell-counting-kit-30-dual-chambered-slides-60-counts-with-trypan-blue 1450003 TC10 Counting Kit Cell Counting Kit, 30 dual-chambered slides, 60 counts, with trypan blue 30 slide pack of dual-chamber slides (60 counts), includes 1.5 ml trypan blue, for use with TC10&trade; or TC20&trade; automated cell counter 30 slide pack of dual-chamber slides (60 counts), includes 1.5 ml trypan blue, for use with TC10&trade; or TC20&trade; automated cell counter /webroot/web/images/lsr/products/cell_counting/sku_thumb/global/145-0003_tn.jpg /webroot/web/images/lsr/products/cell_counting/sku_view/global/145-0003_view.jpg Cell Counting Kit, 30 dual-chambered slides, 60 counts, with trypan blue ,VN Rick Abruzzo Counting Kit 30 dual-chamber counting slides (60 counts), includes 1.5 ml trypan blue 145-0003, 1450003, cell, counting, 30, dual-chambered, slides, 60, counts, trypan, blue, dual, chamber, tc10, tc20, automated, counter, tissue, culture 04/29/10 04:38 PM 04/29/20 04:40 PM AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA,VN en LSR /LSR/Sample-Quantitation/TC10-Automated-Cell-Counter N 0 <p>Use these dual-chamber slides for fast, highly reproducible cell counts using the TC10&trade; or TC20&trade; Automated Cell Counters. The kit contains filter-sterilized 0.4% (w/v) trypan blue in 0.81% sodium chloride and 0.06% potassium phosphate dibasic solution.</p> <ul> <li>Counting parameters &ndash; range of 5 x 10<sup>4</sup> &ndash; 1 &times; 10<sup>7</sup> cells/ml and 6 &ndash; 50 &mu;m cell diameter</li> <li>Each chamber only requires 10 &mu;l of suspended cells</li> <li>Volume counted in each chamber is 0.4 &mu;l (equivalent to four 1 x 1 mm squares of a manual hemocytometer)</li> <li>Both chambers can be loaded prior to insertion</li> <li>Chambers labeled A and B, with arrow next to chamber indicating direction of slide insertion</li> <li>Can be used with or without trypan blue</li> </ul> <p>The counting slides are disposable plastic slides with dual chambers composed of polymethyl methacrylate (PMMA). Each slide is 75 &times; 25 &times; 1.8 mm (W x D x H) with a chamber depth of 100 &mu;m.</p> <h2 class="descHeader">Packaging Options</h2> <table class="pd_table pd_gridlines" border="0"> <tbody> <tr> <td width="319" valign="top"><strong>Number of Dual Chamber Slides<br /></strong></td> <td width="319" valign="top"> <p><strong>Counts</strong></p> </td> <td width="319" valign="top"><strong>Catalog #<br /></strong></td> </tr> <tr class="pd_colorbackground"> <td valign="top">30</td> <td valign="top">60</td> <td valign="top">1450003*</td> </tr> <tr> <td valign="top">30</td> <td valign="top">60</td> <td valign="top"><a href="/en-us/sku/145-0011-counting-slides">1450011</a></td> </tr> <tr class="pd_colorbackground"> <td valign="top">5 x 30</td> <td valign="top">300</td> <td valign="top"><a href="/en-us/sku/145-0015-counting-slides">1450015</a></td> </tr> <tr> <td valign="top">10 x 30</td> <td valign="top">600</td> <td valign="top"><a href="/en-us/sku/145-0016-counting-slides">1450016</a></td> </tr> <tr class="pd_colorbackground"> <td valign="top">20 x 30</td> <td valign="top">1,200</td> <td valign="top"><a href="/en-us/sku/145-0017-counting-slides">1450017</a></td> </tr> <tr> <td valign="top">30 x 30</td> <td valign="top">1,800</td> <td valign="top"><a href="/en-us/sku/145-0018-counting-slides">1450018</a></td> </tr> <tr class="pd_colorbackground"> <td valign="top">40 x 30</td> <td valign="top">2,400</td> <td valign="top"><a href="/en-us/sku/145-0019-counting-slides">1450019</a></td> </tr> <tr> <td valign="top">80 x 30</td> <td valign="top">4,800</td> <td valign="top"><a href="/en-us/sku/145-0020-counting-slides">1450020</a></td> </tr> </tbody> </table> <br /> <p class="caption">*Kit includes 1.5 ml trypan blue</p> <h2 class="descHeader">Related Products</h2> <ul> <li>Trypan Blue, 5 x 1.5 ml, sufficient for 750 counts (<a href="/en-us/sku/145-0021-trypan-blue">1450021</a>) </li> <li>Trypan Blue, 10x 1.5 ml, sufficient for 1500 counts (<a href="/en-us/sku/145-0022-trypan-blue">1450022</a>)</li> </ul> <p>The <a href="/en-us/product/tc20-automated-cell-counter?ID=LZWUOEE8Z">TC20 Automated Cell Counter</a> is available with or without a printer.</p> <h2 class="descHeader">Supporting Documentation</h2> <p>TC20 Automated Cell Counter <a class="no-target-style" href="/webroot/web/pdf/lsr/literature/10024424_RevA_HQ.pdf" target="_blank">Quick Guide</a><br /> TC20 Automated Cell Counter <a class="no-target-style" href="/webroot/web/pdf/lsr/literature/10024423.pdf" target="_blank">Instruction Manual</a></p> /webroot/web/html/lsr/products/SKUs/autopopulated 1450003.html /webroot/web/html/lsr/products/SKUs/autopopulated/1450003.html &nbsp; 0 false null false $ null true false true true false MXN true true true /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450003&quantity= false false /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450003&CartQuote=QT&quantity= 1162 false true false /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450003&AddToDefaultWishList=true&quantity= 41102900 null 1450003
List Price: 
 
Inquire
LoadingLoading...
EDU Price:
  What is this?
Your Price: 
 
LoadingLoading...
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Cart
 
 
Cell Counting Slides for TC10™/TC20™ Cell Counter, Dual-Chamber, 30 slides, 60 counts

1450011
30 slide pack of dual-chamber slides (60 counts), each slide can provide counts for 2 separate samples or dilutions, for use with TC10™ or TC20™ automated cell counter

1450011 /templatedata/internet/product_SKU/data/LSR/Unclassified/145-0011_1347320298.xml 1450011 /default/main/bio-rad/WORKAREA/default 09/10/12 04:36 PM en_US juso9n4j 2018-02-01 00:55:16 true true internet/product_SKU juso9n4j templatedata/internet/product_SKU/data/LSR/Unclassified/145-0011_1347320298.xml LSR 2019-05-04 16:54:09 /default/main/bio-rad/STAGING N /default/main/bio-rad en 09/10/22 04:37 PM 1556045929523 AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA,VN 2019-05-04 16:54:09 /default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Unclassified/145-0011_1347320298.xml templatedata/internet/product_SKU/data/LSR/Unclassified/145-0011_1347320298.xml 1450011-cell-counting-slides-for-tc10-tc20-cell-counter-dual-chamber-30-slides-60-counts 1450011 30 double chamber counting slides (60 count) Cell Counting Slides for TC10™/TC20™ Cell Counter, Dual-Chamber, 30 slides, 60 counts 30 slide pack of dual-chamber slides (60 counts), each slide can provide counts for 2 separate samples or dilutions, for use with TC10&trade; or TC20&trade; automated cell counter 30 slide pack of dual-chamber slides (60 counts), each slide can provide counts for 2 separate samples or dilutions, for use with TC10&trade; or TC20&trade; automated cell counter /webroot/web/images/lsr/products/cell_counting/sku_thumb/global/145-0015_tn.jpg /webroot/web/images/lsr/products/cell_counting/sku_view/global/145-0015_view.jpg Cell Counting Slides for TC10™/TC20™ Cell Counter, Dual-Chamber, 30 slides, 60 counts ,VN TW 30 slide pack of dual-chamber slides (60 counts), each slide can provide counts for 2 separate samples or dilutions, for use with TC10™ or TC20™ automated cell counter 145-0011, 1450011, cell counting slides for tc10/tc20 cell counter, dual-chamber, 30 slides, 60 counts tc10, tc-10, tc20 09/10/12 04:36 PM 09/10/22 04:37 PM AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA,VN en LSR /LSR/Unclassified N 0 <p>Use the dual-chamber slides for fast, highly reproducible cell counts using the TC10 or TC20 automated cell counters.</p> <ul> <li>Counting parameters &ndash; range 5 x 10<sup>4</sup> &ndash; 1 x 10<sup>7</sup> cells/ml and 6 &ndash; 50 &mu;m cell diameter</li> <li>Each chamber only requires 10 &mu;l of suspended cells</li> <li>Volume counted in each chamber is 0.4 &mu;l (equivalent to four 1 x 1 mm squares of a manual hemocytometer)</li> <li>Both chambers can be loaded prior to insertion</li> <li>Chambers labeled A and B, with arrow next to chamber indicating direction of slide insertion</li> </ul> <p>The counting slides are disposable polygon plastic with a dual chamber composed of polymethyl methacrylate (PMMA). Each slide is 75 &times; 25 &times; 1.8 mm (W x D x H) with a chamber depth of 100 &mu;m.</p> <h2 class="descHeader">Packaging Options</h2> <table class="pd_table pd_gridlines" border="0"> <tbody> <tr> <td width="319" valign="top"><strong>Number of dual chamber slides</strong></td> <td width="319" valign="top"> <p><strong>Counts</strong></p> </td> <td width="319" valign="top"><strong>Catalog #</strong></td> </tr> <tr class="pd_colorbackground"> <td valign="top">30</td> <td valign="top">60</td> <td valign="top"><a href="/en-us/sku/1450003-counting-kit">1450003*</a></td> </tr> <tr> <td valign="top">30</td> <td valign="top">60</td> <td valign="top">1450011</td> </tr> <tr class="pd_colorbackground"> <td valign="top">5 x 30</td> <td valign="top">300</td> <td valign="top"><a href="/en-us/sku/145-0015-counting-slides">1450015</a></td> </tr> <tr> <td valign="top">10 x 30</td> <td valign="top">600</td> <td valign="top"><a href="/en-us/sku/145-0016-counting-slides">1450016</a></td> </tr> <tr class="pd_colorbackground"> <td valign="top">20 x 30</td> <td valign="top">1,200</td> <td valign="top"><a href="/en-us/sku/145-0017-counting-slides">1450017</a></td> </tr> <tr> <td valign="top">30 x 30</td> <td valign="top">1,800</td> <td valign="top"><a href="/en-us/sku/145-0018-counting-slides">1450018</a></td> </tr> <tr class="pd_colorbackground"> <td valign="top">40 x 30</td> <td valign="top">2,400</td> <td valign="top"><a href="/en-us/sku/145-0019-counting-slides">1450019</a></td> </tr> <tr> <td valign="top">80 x 30</td> <td valign="top">4,800</td> <td valign="top"><a href="/en-us/sku/145-0020-counting-slides">1450020</a></td> </tr> </tbody> </table> <br /> <p class="caption">*Kit includes 1.5 ml trypan blue</p> <h2 class="descHeader">Related Products</h2> <ul> <li>Trypan Blue, 5 x 1.5 ml, sufficient for 750 counts (<a href="/en-us/sku/145-0021-trypan-blue">1450021</a>) </li> <li>Trypan Blue, 10 x 1.5 ml, sufficient for 1,500 counts (<a href="/en-us/sku/145-0022-trypan-blue">1450022</a>)</li> </ul> <p>The <a href="/en-us/product/tc20-automated-cell-counter?ID=LZWUOEE8Z">TC20 Automated Cell Counter</a> is available with or without a printer.</p> <h2 class="descHeader">Supporting Documentation</h2> <p>TC20 Automated Cell Counter <a href="/webroot/web/pdf/lsr/literature/10024424_RevA_HQ.pdf" target="_blank">Quick Guide</a><br /> TC20 Automated Cell Counter <a href="/webroot/web/pdf/lsr/literature/10024423.pdf" target="_blank">Instruction Manual</a></p> /webroot/web/html/lsr/products/SKUs/autopopulated 1450011.html /webroot/web/html/lsr/products/SKUs/autopopulated/1450011.html 1 0 false null false $ null false false true true false MXN true false true /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450011&quantity= false false /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450011&CartQuote=QT&quantity= 1162 false true false /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450011&AddToDefaultWishList=true&quantity= 31141500 null 1450011
List Price: 
 
Inquire
LoadingLoading...
EDU Price:
  What is this?
Your Price: 
 
LoadingLoading...
Your Price:
 

Communication error

Reload Page

Quantity:  
 
 
Cell Counting Slides for TC10™/TC20™ Cell Counter, Dual-Chamber, 5 x 30 slides, 300 counts

1450015
5 x 30 slide pack of dual-chamber slides (300 counts), each slide can provide counts for 2 separate samples or dilutions, for use with TC10™ or TC20™ automated cell counter

1450015 /templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0015_1272580370.xml 1450015 /default/main/bio-rad/WORKAREA/default 04/29/10 03:30 PM en_US juso9mvh 2018-02-01 00:54:49 true true internet/product_SKU juso9mvh templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0015_1272580370.xml LSR 2019-05-04 16:25:33 /default/main/bio-rad/STAGING N /default/main/bio-rad en 04/29/20 03:32 PM 1556044787949 AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA,VN 2019-05-04 16:25:33 /default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0015_1272580370.xml templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0015_1272580370.xml 1450015-cell-counting-slides-for-tc10-tc20-cell-counter-dual-chamber-5-x-30-slides-300-counts 1450015 TC10 Counting slides, includes 150 double chamber counting slides (300 count) Cell Counting Slides for TC10™/TC20™ Cell Counter, Dual-Chamber, 5 x 30 slides, 300 counts 5 x 30 slide pack of dual-chamber slides (300 counts), each slide can provide counts for 2 separate samples or dilutions, for use with TC10&trade; or TC20&trade; automated cell counter 5 x 30 slide pack of dual-chamber slides (300 counts), each slide can provide counts for 2 separate samples or dilutions, for use with TC10&trade; or TC20&trade; automated cell counter /webroot/web/images/lsr/products/cell_counting/sku_thumb/global/145-0015_tn.jpg /webroot/web/images/lsr/products/cell_counting/sku_view/global/145-0015_view.jpg Cell Counting Slides for TC10™/TC20™ Cell Counter, Dual-Chamber, 5 x 30 slides, 300 counts ,VN Rick Abruzzo TC20&#153; Counting Slides 150 dual-chamber slides (300 counts), dual-chamber slides can provide counts for 2 separate samples or dilutions 145-0015, 1450015, cell, counting, slides, tc10/tc20, counter, dual-chamber, 5x30, 300, counts, tc10, tc20, automated, dual, chamber, tissue, culture 04/29/10 03:30 PM 04/29/20 03:32 PM AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA,VN en LSR /LSR/Sample-Quantitation/TC10-Automated-Cell-Counter N 0 <p>Use the dual-chamber slides for fast, highly reproducible cell counts using the TC10 or TC20 automated cell counters.</p> <ul> <li>Counting parameters &ndash; range 5 &times; 10<sup>4</sup> &ndash; 1 &times; 10<sup>7</sup> cells/ml and 6 &ndash; 50 &mu;m cell diameter</li> <li>Each chamber only requires 10 &mu;l of suspended cells</li> <li>Volume counted in each chamber is 0.4 &mu;l (equivalent to four 1 x 1 mm squares of a manual hemocytometer)</li> <li>Both chambers can be loaded prior to insertion</li> <li>Chambers labeled A and B, with arrow next to chamber indicating direction of slide insertion</li> <li>Can be used with or without trypan blue</li> </ul> <p>The counting slides are disposable polygon plastic with a dual chamber composed of polymethyl methacrylate (PMMA). Each slide is 75 &times; 25 &times; 1.8 mm (W x D x H) with a chamber depth of 100 &mu;m.</p> <h2 class="descHeader">Packaging Options</h2> <table class="pd_table pd_gridlines" border="0"> <tbody> <tr> <td width="319" valign="top"><strong>Number of dual chamber slides</strong></td> <td width="319" valign="top"> <p><strong>Counts</strong></p> </td> <td width="319" valign="top"><strong>Catalog #</strong></td> </tr> <tr class="pd_colorbackground"> <td valign="top">30</td> <td valign="top">60</td> <td valign="top"><a href="/en-us/sku/1450003-counting-kit">1450003</a>*</td> </tr> <tr> <td valign="top">30</td> <td valign="top">60</td> <td valign="top"><a href="/en-us/sku/145-0011-counting-slides">1450011</a></td> </tr> <tr class="pd_colorbackground"> <td valign="top">5 x 30</td> <td valign="top">300</td> <td valign="top">1450015</td> </tr> <tr> <td valign="top">10 x 30</td> <td valign="top">600</td> <td valign="top"><a href="/en-us/sku/145-0016-counting-slides">1450016</a></td> </tr> <tr class="pd_colorbackground"> <td valign="top">20 x 30</td> <td valign="top">1,200</td> <td valign="top"><a href="/en-us/sku/145-0017-counting-slides">1450017</a></td> </tr> <tr> <td valign="top">30 x 30</td> <td valign="top">1,800</td> <td valign="top"><a href="/en-us/sku/145-0018-counting-slides">1450018</a></td> </tr> <tr class="pd_colorbackground"> <td valign="top">40 x 30</td> <td valign="top">2,400</td> <td valign="top"><a href="/en-us/sku/145-0019-counting-slides">1450019</a></td> </tr> <tr> <td valign="top">80 x 30</td> <td valign="top">4,800</td> <td valign="top"><a href="/en-us/sku/145-0020-counting-slides">1450020</a></td> </tr> </tbody> </table> <br /> <p class="caption">*Kit includes 1.5 ml trypan blue</p> <h2 class="descHeader">Related Products</h2> <ul> <li>Trypan Blue, 5 x 1.5 ml, sufficient for 750 counts (<a href="/en-us/sku/145-0021-trypan-blue">1450021</a>) </li> <li>Trypan Blue, 10x 1.5 ml, sufficient for 1,500 counts (<a href="/en-us/sku/145-0022-trypan-blue">1450022</a>)</li> </ul> <p>The <a href="/en-us/product/tc20-automated-cell-counter?ID=LZWUOEE8Z">TC20 Automated Cell Counter</a> is available with or without a printer.</p> <h2 class="descHeader">Supporting Documentation</h2> <p>TC20 Automated Cell Counter <a class="no-target-style" href="/webroot/web/pdf/lsr/literature/10024424_RevA_HQ.pdf" target="_blank">Quick Guide</a><br /> TC20 Automated Cell Counter <a class="no-target-style" href="/webroot/web/pdf/lsr/literature/10024423.pdf" target="_blank">Instruction Manual</a></p> /webroot/web/html/lsr/products/SKUs/autopopulated 1450015.html /webroot/web/html/lsr/products/SKUs/autopopulated/1450015.html &nbsp; 0 false null false $ null true false true true false MXN true true true /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450015&quantity= false false /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450015&CartQuote=QT&quantity= 1162 false true false /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450015&AddToDefaultWishList=true&quantity= 41115800 null 1450015
List Price: 
 
Inquire
LoadingLoading...
EDU Price:
  What is this?
Your Price: 
 
LoadingLoading...
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Cart
 
 
Cell Counting Slides for TC10™/TC20™ Cell Counter, Dual-Chamber, 40 x 30 slides, 2,400 counts

1450019
40 x 30 slide pack of dual-chamber slides (2,400 counts), each slide can provide counts for 2 separate samples or dilutions, for use with TC10™ or TC20™ automated cell counter

1450019 /templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0019_1272583407.xml 1450019 /default/main/bio-rad/WORKAREA/default 04/29/10 04:19 PM en_US juso9mvf 2018-02-01 00:54:49 true true internet/product_SKU juso9mvf templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0019_1272583407.xml LSR 2019-05-04 16:25:28 /default/main/bio-rad/STAGING N /default/main/bio-rad en 04/29/20 04:23 PM 1556044788137 AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA,VN 2019-05-04 16:25:28 /default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0019_1272583407.xml templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0019_1272583407.xml 1450019-cell-counting-slides-for-tc10-tc20-cell-counter-dual-chamber-40-x-30-slides-2-400-counts 1450019 TC10 Counting slides includes 1200 double chamber counting slides (2400 count) Cell Counting Slides for TC10™/TC20™ Cell Counter, Dual-Chamber, 40 x 30 slides, 2,400 counts 40 x 30 slide pack of dual-chamber slides (2,400 counts), each slide can provide counts for 2 separate samples or dilutions, for use with TC10&trade; or TC20&trade; automated cell counter 40 x 30 slide pack of dual-chamber slides (2,400 counts), each slide can provide counts for 2 separate samples or dilutions, for use with TC10&trade; or TC20&trade; automated cell counter /webroot/web/images/lsr/products/cell_counting/sku_thumb/global/145-0015_tn.jpg /webroot/web/images/lsr/products/cell_counting/sku_view/global/145-0015_view.jpg Cell Counting Slides for TC10™/TC20™ Cell Counter, Dual-Chamber, 40 x 30 slides, 2,400 counts ,VN Rick Abruzzo Counting Slides 1,200 dual-chamber slides (2,400 counts), dual-chamber slides can provide counts for 2 separate samples or dilutions 145-0019, 1450019, cell, counting, slides, tc10/tc20, counter, dual-chamber, 40x30, 2400, counts, tc10, tc20, automated, dual, chamber, tissue, culture 04/29/10 04:19 PM 04/29/20 04:23 PM AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA,VN en LSR /LSR/Sample-Quantitation/TC10-Automated-Cell-Counter N 0 <p>Use the dual-chamber slides for fast, highly reproducible cell counts using the TC10 or TC20 automated cell counters.</p> <ul> <li>Counting parameters &ndash; range 5 &times; 10<sup>4</sup> &ndash; 1 &times; 10<sup>7</sup> cells/ml and 6 &ndash; 50 &mu;m cell diameter</li> <li>Each chamber only requires 10 &mu;l of suspended cells</li> <li>Volume counted in each chamber is 0.4 &mu;l (equivalent to four 1 x 1 mm squares of a manual hemocytometer)</li> <li>Both chambers can be loaded prior to insertion</li> <li>Chambers labeled A and B, with arrow next to chamber indicating direction of slide insertion</li> <li>Can be used with or without trypan blue</li> </ul> <p>The counting slides are disposable polygon plastic with a dual chamber composed of polymethyl methacrylate (PMMA). Each slide is 75 &times; 25 &times; 1.8 mm (W x D x H) with a chamber depth of 100 &mu;m.</p> <h2 class="descHeader">Packaging Options</h2> <table class="pd_table pd_gridlines" border="0"> <tbody> <tr> <td width="319" valign="top"><strong>Number of dual chamber slides</strong></td> <td width="319" valign="top"> <p><strong>Counts</strong></p> </td> <td width="319" valign="top"><strong>Catalog #</strong></td> </tr> <tr class="pd_colorbackground"> <td valign="top">30</td> <td valign="top">60</td> <td valign="top"><a href="/en-us/sku/1450003-counting-kit">1450003</a>*</td> </tr> <tr> <td valign="top">30</td> <td valign="top">60</td> <td valign="top"><a href="/en-us/sku/145-0011-counting-slides">1450011</a></td> </tr> <tr class="pd_colorbackground"> <td valign="top">5 x 30</td> <td valign="top">300</td> <td valign="top"><a href="/en-us/sku/1450015-counting-slides">1450015</a></td> </tr> <tr> <td valign="top">10 x 30</td> <td valign="top">600</td> <td valign="top"><a href="/en-us/sku/145-0016-counting-slides">1450016</a></td> </tr> <tr class="pd_colorbackground"> <td valign="top">20 x 30</td> <td valign="top">1,200</td> <td valign="top"><a href="/en-us/sku/145-0017-counting-slides">1450017</a></td> </tr> <tr> <td valign="top">30 x 30</td> <td valign="top">1,800</td> <td valign="top"><a href="/en-us/sku/145-0018-counting-slides">1450018</a></td> </tr> <tr class="pd_colorbackground"> <td valign="top">40 x 30</td> <td valign="top">2,400</td> <td valign="top">1450019</td> </tr> <tr> <td valign="top">80 x 30</td> <td valign="top">4,800</td> <td valign="top"><a href="/en-us/sku/145-0020-counting-slides">1450020</a></td> </tr> </tbody> </table> <br /> <p class="caption">*Kit includes 1.5 ml trypan blue</p> <h2 class="descHeader">Related Products</h2> <ul> <li>Trypan Blue, 5 x 1.5 ml, sufficient for 750 counts (<a href="/en-us/sku/145-0021-trypan-blue">1450021</a>) </li> <li>Trypan Blue, 10 x 1.5 ml, sufficient for 1,500 counts (<a href="/en-us/sku/145-0022-trypan-blue">1450022</a>)</li> </ul> <p>The <a href="/en-us/product/tc20-automated-cell-counter?ID=LZWUOEE8Z">TC20 Automated Cell Counter</a> is available with or without a printer.</p> <h2 class="descHeader">Supporting Documentation</h2> <p>TC20 Automated Cell Counter <a class="no-target-style" href="/webroot/web/pdf/lsr/literature/10024424_RevA_HQ.pdf" target="_blank">Quick Guide</a><br /> TC20 Automated Cell Counter <a class="no-target-style" href="/webroot/web/pdf/lsr/literature/10024423.pdf" target="_blank">Instruction Manual</a></p> /webroot/web/html/lsr/products/SKUs/autopopulated 1450019.html /webroot/web/html/lsr/products/SKUs/autopopulated/1450019.html &nbsp; 0 false null false $ null false false true true false MXN true false true /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450019&quantity= false false /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450019&CartQuote=QT&quantity= 1162 false true false /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450019&AddToDefaultWishList=true&quantity= 41115800 null 1450019
List Price: 
 
Inquire
LoadingLoading...
EDU Price:
  What is this?
Your Price: 
 
LoadingLoading...
Your Price:
 

Communication error

Reload Page

Quantity:  
 
 
System Test Kit

1450014
Kit for validation of TC10™ or TC20™ automated cell counter functionality, includes verification slide, instructions

1450014 /templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0014_1272650313.xml 1450014 /default/main/bio-rad/WORKAREA/default 04/30/10 09:44 AM en_US juso9mv9 2017-11-14 07:09:01 true true internet/product_SKU juso9mv9 templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0014_1272650313.xml LSR 2019-05-04 16:25:21 /default/main/bio-rad/STAGING N /default/main/bio-rad en 04/30/20 10:57 AM 1556044787901 AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA,VN 2019-05-04 16:25:21 /default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0014_1272650313.xml templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0014_1272650313.xml 1450014-system-test-kit 1450014 TC10 Verification Kit System Test Kit Kit for validation of TC10&#153; or TC20&#153; automated cell counter functionality, includes verification slide, instructions /webroot/web/images/lsr/products/sample_quantitation/sku_thumb/global/145-0014_tn.jpg /webroot/web/images/lsr/products/sample_quantitation/sku_view/global/145-0014_view.jpg ,VN Rick Abruzzo System Test Kit Kit for validation of TC10&#153; or TC20&#153; automated cell counter functionality, includes verification slide, protocol instructions Kit for validation of TC10&#153; or TC20&#153; automated cell counter functionality, includes verification slide, protocol instructions 04/30/10 09:44 AM 04/30/20 10:57 AM AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA,VN en LSR /LSR/Sample-Quantitation/TC10-Automated-Cell-Counter N 0 &nbsp; 0 false null false $ null false false true true false MXN true false true /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450014&quantity= false false /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450014&CartQuote=QT&quantity= 1162 false true false /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450014&AddToDefaultWishList=true&quantity= 41116500 null 1450014
List Price: 
 
Inquire
LoadingLoading...
EDU Price:
  What is this?
Your Price: 
 
LoadingLoading...
Your Price:
 

Communication error

Reload Page

Quantity:  
 
 
Thermal Label Printer

1450005
120–240 V, connects to the TC10™ or TC20™ automated cell counter, for printing results onto labels, includes thermal label printer, USB cable, 1 roll of 500 labels

1450005 /templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0005_1272579624.xml 1450005 /default/main/bio-rad/WORKAREA/default 04/29/10 03:16 PM en_US juso9mv7 2017-11-14 07:09:01 true true internet/product_SKU juso9mv7 templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0005_1272579624.xml LSR 2019-05-04 16:25:20 /default/main/bio-rad/STAGING N /default/main/bio-rad en 04/29/20 03:19 PM 1556044787737 AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA,VN 2019-05-04 16:25:20 /default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0005_1272579624.xml templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0005_1272579624.xml 1450005-thermal-label-printer 1450005 TC10 thermal printer, 100-240V Thermal Label Printer 120&#150;240 V, connects to the TC10&#153; or TC20&#153; automated cell counter, for printing results onto labels, includes thermal label printer, USB cable, 1 roll of 500 labels 120&#150;240 V, connects to the TC10&#153; or TC20&#153; automated cell counter, for printing results onto labels, includes thermal label printer, USB cable, 1 roll of 500 labels /webroot/web/images/lsr/products/sample_quantitation/sku_thumb/global/145-0005_tn.jpg /webroot/web/images/lsr/products/sample_quantitation/sku_view/global/145-0005_view.jpg ,VN Rick Abruzzo Thermal Label Printer Connects to the TC10&#153; or TC20&#153; automated cell counter, for printing results onto labels, includes thermal label printer, USB cable, 1 roll of 185 labels Connects to the TC10&#153; or TC20&#153; automated cell counter, for printing results onto labels, includes thermal label printer, USB cable, 1 roll of 185 labels 04/29/10 03:16 PM 04/29/20 03:19 PM AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA,VN en LSR /LSR/Sample-Quantitation/TC10-Automated-Cell-Counter N 0 &nbsp; 0 false null false $ null false false true true false MXN true false true /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450005&quantity= false false /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450005&CartQuote=QT&quantity= 1162 false true false /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450005&AddToDefaultWishList=true&quantity= 32121500 null 1450005
List Price: 
 
Inquire
LoadingLoading...
EDU Price:
  What is this?
Your Price: 
 
LoadingLoading...
Your Price:
 

Communication error

Reload Page

Quantity:  
 
 
Thermal Printer Labels

1450007
Pkg of 1 roll, 500 labels, for use with thermal label printer for printing results obtained with the TC10™ or TC20™ automated cell counter

1450007 /templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0007_1272580006.xml 1450007 /default/main/bio-rad/WORKAREA/default 04/29/10 03:23 PM en_US juso9mvg 2017-11-14 07:09:01 true true internet/product_SKU juso9mvg templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0007_1272580006.xml LSR 2019-05-04 16:25:29 /default/main/bio-rad/STAGING N /default/main/bio-rad en 04/29/20 03:26 PM 1556044787791 AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA,VN 2019-05-04 16:25:29 /default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0007_1272580006.xml templatedata/internet/product_SKU/data/LSR/Sample-Quantitation/TC10-Automated-Cell-Counter/145-0007_1272580006.xml 1450007-thermal-printer-labels 1450007 Printer Labels Thermal Printer Labels Pkg of 1 roll, 500 labels, for use with thermal label printer for printing results obtained with the TC10&#153; or TC20&#153; automated cell counter Pkg of 1 roll, 500 labels, for use with thermal label printer for printing results obtained with the TC10&#153; or TC20&#153; automated cell counter /webroot/web/images/lsr/products/sample_quantitation/sku_thumb/global/145-0007_tn.jpg /webroot/web/images/lsr/products/sample_quantitation/sku_view/global/145-0007_view.jpg /webroot/web/images/lsr/products/sample_quantitation/sku_feature/global/145-0007_feature.jpg ,VN Rick Abruzzo Thermal Printer Labels Pkg of 1 roll, 185 labels, for use with thermal label printer for printing results obtained with the TC10&#153; or TC20&#153; automated cell counter 145-0007, 1450007, thermal, printer, labels, printing, tc10, tc20, automated, cell, counter 04/29/10 03:23 PM 04/29/20 03:26 PM AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA,VN en LSR /LSR/Sample-Quantitation/TC10-Automated-Cell-Counter N 0 &nbsp; 0 false null false $ null false false true true false MXN true false true /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450007&quantity= false false /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450007&CartQuote=QT&quantity= 1162 false true false /prd/en/MX/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=1450007&AddToDefaultWishList=true&quantity= 55121600 null 1450007
List Price: 
 
Inquire
LoadingLoading...
EDU Price:
  What is this?
Your Price: 
 
LoadingLoading...
Your Price:
 

Communication error

Reload Page

Quantity:  
 
 
x

Account price failed to display. Please try reloading the page.Reload Page

If you are placing an order, you may proceed with your order; the account price will be applied if it is lower than the
list price. If the problem persists, please call customer service at or send an
email to

TC20™ Data Analyzer Software

SOFT-TC20-Data-Analyzer
TC20 data analyzer software, compatible with JPEG image files from the TC20 automated cell counter

TC20™ Automated Cell Counter Firmware

SOFT-TC20-FW
Firmware update for the TC20 cell counter, version 2.058

Number Description Options
10024423 Instruction Manual, TC20 Automated Cell Counter, Rev B Click to download
10024424 Quick Guide, TC20 Automated Cell Counter, Rev A Click to download
10018213 Instruction Manual, TC10™ and TC20™ Verification Slide, Rev C Click to download
6283 TC20 Automated Cell Counter Brochure, Rev B Click to download [ Add to Cart (Free) ]
6282 TC20 Automated Cell Counter Product Information Sheet, Rev A Click to download [ Add to Cart (Free) ]
6087 Comparison between the TC10 Automated Cell Counter and the Lactate Dehydrogenase (LDH) Assay to Assess Cellular Toxicity in Vitro, Rev A Click to download
6003 Comparison of Count Reproducibility, Accuracy, and Time to Results between a Hemocytometer and the TC20 Automated Cell Counter, Rev B Click to download [ Add to Cart (Free) ]
6011 Multifocal Plane Analysis Is Essential for Accurate Cell Viability Assessment Using an Automated Cell Counter, Rev B Click to download
6152 Accurate Counting of Bio-Plex Magnetic or Polystyrene Beads Using the TC10 Automated Cell Counter, Rev A Click to download
6777 Protocol for Single Cell Gene Expression Profiling by Multiplex RT-qPCR Click to download
6340 A Comparison of the TC10™ Automated Cell Counter and the Hemocytometer for Quantifying Insect Hemocytes, Rev A Click to download
6853 Reliable Single-Cell Sorting with Bio-Rad's S3e™ Cell Sorter Application Note Click to download

This product contains electrical or electronic material. Learn more about Bio-Rad's EU Recycle Program

Get Help
Sign Up for Bio-Rad Updates!
Enter your email address below to receive your choice of the latest news, promotions, and more.
M7FBG34VY [x-forwarded-proto] = [https] [accept-language] = [en-US,en;q=0.5] [x-forwarded-port] = [443] [x-forwarded-for] = [3.85.245.126, 10.232.3.225] [accept] = [text/html,application/xhtml+xml,application/xml;q=0.9,*/*;q=0.8] [seourl] = [/en-mx/product/tc20-automated-cell-counter] [x-amzn-trace-id] = [Root=1-5dac4f69-4010fc902b919b5c487f79be] [x-forwarded-server] = [lsds-prod-s.br.aws-livesite.io] [x-forwarded-host] = [www.bio-rad.com] [x-query-string] = [ID=M7FBG34VY] [host] = [10.232.0.21:1776] [x-request-uri] = [/en-mx/product/tc20-automated-cell-counter] [connection] = [Keep-Alive] [accept-encoding] = [gzip] [user-agent] = [CCBot/2.0 (https://commoncrawl.org/faq/)] Catalog/ProductDetail pageStyleKey tc20-automated-cell-counter LSR https://www.bio-rad-antibodies.com https://www.bio-rad.com 10/05/13 01:04 AM en_US true internet/generic 2019-07-01 01:54:37 /default/main/bio-rad/STAGING 1380960299662 AL,DZ,AI,AR,AM,AZ,BH,BD,BA,BW,BN,BG,BF,KH,CM,HR,CY,DO,EG,ER,ET,FO,GF,PF,GA,GE,GH,GP,GU,HT,HN,HU,JM,JO,KZ,KE,XK,KW,LB,LI,MO,MK,MG,ML,MQ,MU,FM,MD,MS,MA,NP,NI,NG,OM,PK,PW,PS,PA,PG,PR,QA,RO,ST,SA,SN,RS,SK,SI,SB,LK,TZ,TG,TO,TN,TR,UG,UA,AE,UZ,VU,VA,VN,EH,YE,BO,BR,CA,CL,CO,CR,EC,SV,GT,MX,PY,PE,TT,US,UY,VE,AU,CN,HK,IN,ID,JP,KR,MY,NZ,PH,SG,TW,TH,AT,BE,CZ,DK,EE,FI,DE,GR,IS,IE,IL,IT,LV,LT,LU,MT,NL,NO,PL,PT,RU,ZA,ES,SE,CH,UK templatedata/internet/generic/data/GNL/page_generic_footer_b2c_1380960409_XX.xml page_generic_footer_b2c /default/main/bio-rad/WORKAREA/default jcc1tp9h 2017-11-14 06:29:33 true jcc1tp9h templatedata/internet/generic/data/GNL/page_generic_footer_b2c_1380960409_XX.xml GNL N /default/main/bio-rad en 05/20/37 02:13 PM 1561770577111 2019-07-01 01:54:37 /default/main/bio-rad/WORKAREA/default/templatedata/internet/generic/data/GNL/page_generic_footer_b2c_1380960409_XX.xml footer 1 1380960299662 page_generic_footer_b2c <div class="col"> <h4>Support</h4> <ul> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/life-science-research/support?ID=1140">Life Science Support</a></li> <li><a class="wtclass linkgeneration" href="_acdDomain/technical-support.html">Antibodies Support</a></li> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/life-science-research/purchase-service-programs/expert-care-service?ID=1383780912356">Expert Care Service</a></li> <li><a class="wtclass linkgeneration" href="_brcDomain/contact">Contact Us</a></li> </ul> </div> <div class="col"> <h4>Documents</h4> <ul> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/literature-library">Literature Library</a></li> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/life-science-research/support/certificate-of-analysis">Certificate of Analysis</a></li> <li><a class="wtclass" href="https://myeinserts.qcnet.com/" target="_blank" rel="noopener noreferrer">QC Inserts</a></li> <li><a class="wtclass linkgeneration" href="_acdDomain/iso-9001-quality-assurance-management.html">Quality Certification</a></li> </ul> </div> <div class="col"> <h4>Ordering</h4> <ul> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/my-bio-rad">Quick Order</a></li> <li><a id="footer_orderLink" class="orderhistoryLink wtclass" href="javascript:void(0);">Order History</a></li> <li><a class="wtclass" id="footer_quoteLink" href="javascript:void(0);">Quote History</a></li> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/my-bio-rad">My Bio-Rad</a></li> <li><a class="wtclass linkgeneration hidden MX-exclude AR-exclude BO-exclude CL-exclude CO-exclude CR-exclude DO-exclude EC-exclude SV-exclude GT-exclude HN-exclude NI-exclude PA-exclude PY-exclude PE-exclude UY-exclude VE-exclude JP-exclude" href="_brcDomain/_locale/life-science-research/purchase-service-programs/supply-center-program?ID=1383773882551">Supply Centers</a></li> </ul> </div> <div class="col"> <h4>Our Products</h4> <ul> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/life-science-research?ID=1100">Life Science Research</a></li> <li><a class="wtclass linkgeneration" href="_acdDomain/">Antibodies</a></li> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/clinical-diagnostics?ID=1200">Clinical Diagnostics</a></li> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/spectroscopy?ID=1300">Spectroscopy</a></li> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/process-separations?ID=1400">Process Separations</a></li> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/food-science?ID=1475">Food Science</a></li> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/education?ID=1450">Life Science Education</a></li> </ul> </div> <div class="col"> <h4>Company</h4> <ul> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/corporate/about-bio-rad?ID=1003">About Bio-Rad</a></li> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/corporate/careers?ID=1004">Careers</a></li> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/corporate/investor-relations?ID=1007">Investor Relations</a></li> <li><a class="wtclass linkgeneration" href="_brcDomain/_locale/corporate/newsroom?ID=1006">Newsroom</a></li> <li><a class="wtclass linkgeneration" href="_acdDomain/blog/">Blog</a></li> <li><a class="wtclass" target="_blank" href="https://www.bioradiations.com" rel="noopener noreferrer">Bioradiations</a></li> <li> <div class="social"> <ul> <li><a class="no-target-style brconly wtclass" href="https://www.linkedin.com/company/bio-rad?trk=top_nav_home" target="_blank" rel="noopener noreferrer"><img src="https://www.bio-rad.com/webroot/web/images/general/icons/linkedin_round_40x40.png" alt="Bio-Rad LinkedIn" width="20" height="20" /></a> <a class="no-target-style bracd wtclass" style="display: none;" href="https://www.linkedin.com/company/bio-rad-antibodies" target="_blank" rel="noopener noreferrer"><img src="https://www.bio-rad.com/webroot/web/images/general/icons/linkedin_round_40x40.png" alt="Bio-Rad Antibodies LinkedIn" width="20" height="20" /></a></li> <li><a class="no-target-style brconly wtclass" href="https://www.youtube.com/user/BioRadLifeScience" target="_blank" rel="noopener noreferrer"><img src="https://www.bio-rad.com/webroot/web/images/general/icons/youtube-icon-rnd-40x40.png" alt="Bio-Rad YouTube" width="20" height="20" /></a> <a class="no-target-style bracd wtclass" style="display: none;" href="https://www.youtube.com/playlist?list=PLrAEgIY86I6w1jajKp3O9RQJEvJZ2ux0I" target="_blank" rel="noopener noreferrer"><img src="https://www.bio-rad.com/webroot/web/images/general/icons/youtube-icon-rnd-40x40.png" alt="Bio-Rad Antibodies YouTube" width="20" height="20" /></a></li> <li><a class="no-target-style brconly wtclass" href="https://twitter.com/BioRadLifeSci" target="_blank" rel="noopener noreferrer"><img src="https://www.bio-rad.com/webroot/web/images/general/icons/twitter_round_40x40.png" alt="Bio-Rad Twitter" width="20" height="20" /></a> <a class="no-target-style bracd wtclass" style="display: none;" href="https://twitter.com/BioRadAbs" target="_blank" rel="noopener noreferrer"><img src="https://www.bio-rad.com/webroot/web/images/general/icons/twitter_round_40x40.png" alt="Bio-Rad Antibodies Twitter" width="20" height="20" /></a></li> <li><a class="no-target-style brconly wtclass" href="https://www.facebook.com/biorad/" target="_blank" rel="noopener noreferrer"><img src="https://www.bio-rad.com/webroot/web/images/general/icons/facebook-icon-rnd-40x40.png" alt="Bio-Rad Facebook" width="20" height="20" /></a> <a class="no-target-style bracd wtclass" style="display: none;" href="https://www.facebook.com/BioRadAntibodies" target="_blank" rel="noopener noreferrer"><img src="https://www.bio-rad.com/webroot/web/images/general/icons/facebook-icon-rnd-40x40.png" alt="Bio-Rad Antibodies Facebook" width="20" height="20" /></a></li> <li><a class="no-target-style wtclass" href="https://www.instagram.com/bioradlabs/" target="_blank" rel="noopener noreferrer"><img src="https://www.bio-rad.com/webroot/web/images/general/icons/instagram-icon-rnd-40x40.png" alt="Bio-Rad Instagram" width="20" height="20" /></a></li> <li><a class="no-target-style wtclass" href="https://uk.pinterest.com/BioRadAbs/" target="_blank" rel="noopener noreferrer"><img src="https://www.bio-rad.com/webroot/web/images/general/icons/pinterest40x40.png" alt="Bio-Rad Pinterest" width="20" height="20" /></a></li> </ul> </div> </li> </ul> </div> /webroot/web/html footer_page_b2c_xx.html /webroot/web/html/footer_page_b2c_xx.html Sai Mandadhi Footer footer 10/05/13 01:04 AM 05/20/37 02:13 PM AL,DZ,AI,AR,AM,AZ,BH,BD,BA,BW,BN,BG,BF,KH,CM,HR,CY,DO,EG,ER,ET,FO,GF,PF,GA,GE,GH,GP,GU,HT,HN,HU,JM,JO,KZ,KE,XK,KW,LB,LI,MO,MK,MG,ML,MQ,MU,FM,MD,MS,MA,NP,NI,NG,OM,PK,PW,PS,PA,PG,PR,QA,RO,ST,SA,SN,RS,SK,SI,SB,LK,TZ,TG,TO,TN,TR,UG,UA,AE,UZ,VU,VA,VN,EH,YE,BO,BR,CA,CL,CO,CR,EC,SV,GT,MX,PY,PE,TT,US,UY,VE,AU,CN,HK,IN,ID,JP,KR,MY,NZ,PH,SG,TW,TH,AT,BE,CZ,DK,EE,FI,DE,GR,IS,IE,IL,IT,LV,LT,LU,MT,NL,NO,PL,PT,RU,ZA,ES,SE,CH,UK en GNL /GNL N 0 en-mx Home Trademarks Site Terms Terms & Conditions Imprint EU Recycle Program Privacy Change Cookie Setting <script type="text/javascript">$(document).ready(function () {$(".links2").append('<style>.social-links-br {float: left;margin-right: 10px;}.social-links-br img {width: 20px;height: 20px;margin-right: 5px}</style><div class="social-links-br"><a class="no-target-style" href="https://www.linkedin.com/company/bio-rad?trk=top_nav_home" target="_blank"><img src="/webroot/web/images/general/icons/linkedin_round_40x40.png" alt="Bio-Rad LinkedIn"></a><a class="no-target-style" href="https://www.youtube.com/user/BioRadLifeScience" target="_blank"><img src="/webroot/web/images/general/icons/youtube-icon-rnd-40x40.png" alt="Bio-Rad YouTube"></a><a class="no-target-style" href="https://twitter.com/BioRadLifeSci" target="_blank"><img src="/webroot/web/images/general/icons/twitter_round_40x40.png" alt="Bio-Rad Twitter"></a><a class="no-target-style" href="https://www.facebook.com/biorad/" target="_blank"><img src="/webroot/web/images/general/icons/facebook-icon-rnd-40x40.png" alt="Bio-Rad Facebook"></a><a class="no-target-style" href="https://www.instagram.com/bioradlabs/" target="_blank"><img src="/webroot/web/images/general/icons/instagram-icon-rnd-40x40.png" alt="Bio-Rad Instagram"></a></div>');});</script>&copy; {0} Bio-Rad Laboratories, Inc. This page was last edited on {0} true True GTM-MJ2DN2S mx MX en LSR life-science-research life-science-research /prd/en/MX/direct/biorad?ts=1&cmd=OrdersWorkspaceDisplay /prd/en/MX/direct/biorad?ts=1&cmd=QuotesWorkspaceDisplay /prd/en/MX/direct/biorad?ts=1&cmd=InvoiceWorkspaceDisplay&_Tab=Invoice false false true false true true 1040988879 LHsYCOu_wQMQz_Ww8AM window.google_tag_params true 272-THL-329 username CartID_ WT_FPC <script type="text/javascript">$.ajax({url: document.location.protocol + '//munchkin.marketo.net/munchkin.js',dataType: 'script',cache: true,success: function() {Munchkin.init('044-CBN-599');}});</script> <script type="text/javascript" src="https://www.bio-rad.com/evportal/framework/skins/evolution/js/proxyMunchkin.js"></script> 2019 {"country":"mx","b2b_punch_out_mode":"","pageType":"Product Detail Page","user_id":"","visitorLoginState":false,"visitorType":"","sessionType":"B2C","language":"en","vertical":"LSR","b2b_org_id":""}