Bio-Scale™ Mini Cartridge Sampler Packs

print

Overview

Bio-Scale™ Mini Cartridge Selection Guide
Cartridge by ApplicationSupportType of SeparationChemical FormProtein Capacity/ml*Catalog Numbers by Cartridge Size
5 x 1 ml1 x 5 ml5 x 5 ml
Protein and Plasmid Purification
High QMacro-Prep® High QStrong anion exchange–N+(CH3)3≥37 mg BSA732-4120732-4122732-4124
UNOsphere™ QUNOsphereQStrong anion exchange–N+(CH3)3180 mg BSA732-4100732-4102732-4104
UNOsphere SUNOsphere SStrong cation exchange–SO3-60 mg human lgG732-4110732-4112732-4114
DEAEMacro-Prep DEAEWeak anion exchange–HN+(C2H5)2>35 mg protein732-4140732-4142732-4144
Protein Purification
High SMacro-Prep High SStrong cation exchange–SO3-≥49 mg human lgG732-4130732-4132732-4134
IgG Purification
DEAE BlueDEAE Affi-Gel® Blue Affinity

Cibacron Blue

F3GA and DEAE

0.2–1.0 ml serum

732-4632732-4634
Antibody Purification
Protein AUNOsphere SUPrA™AffinityRecombinant protein A30 mg/ml human IgG
732-4200, 1 x 1 ml732-4201, 5 x 1 ml732-4202, 1 x 5 ml
Protein AAffi-Prep®
protein A
AffinityProtein A8–10 mg mouse
monoclonal lgG1;
16–23 mg human lgG
732-4600732-4602
CHT Type ICHT™ ceramic
hydroxyapatite
Type I, 40 µm
Hydroxyapatite(Ca5(PO4)3OH)225–60 mg human lgG
732-4322732-4324
CHT Type IICHT ceramic
hydroxyapatite
Type II, 40 µm
Hydroxyapatite(Ca5(PO4)3OH)215–25 mg human lgG
732-4332732-4334
Affinity-Tagged Protein Purification
IMACProfinity™ IMACAffinityIminodiacetic acid≥15 mg recombinant
histidine (His)-tagged protein
732-4610732-4612732-4614
GSTProfinity GSTAffinityGlutathione≥10 mg/ml recombinant
GST-tagged protein
732-4620732-4622732-4624
Purification of Serum Proteins, Enzymes
BlueAffi-Gel BlueAffinityCibacron Blue
F3GA
0.2 ml serum
11 mg albumin
732-4642732-4644

Cartridge by ApplicationSupportType of SeparationChemical FormProtein Capacity/ml*Catalog Numbers by Cartridge Size
1 x 5 ml5 x 5 ml5 x 10 ml1 x 50 ml5 x 50 ml
Desalting, Buffer Exchange
P-6Bio-Gel® P-6Gel filtrationPolyacrylamide10–22% CV**732-
4502
732-
4504
732-
5304
732-
5312
732-
5314

* Purification capacity based on bulk support; check individual instruction manuals for run conditions and specifications.
** Column volume.

PDF Bulletin 5584 To read more click here

Bio-Scale Mini Cartridge Specifications
Sizes 1 ml and 5 ml bed volumes; desalting cartridges: 10 ml and 50 ml bed volumes
Recommended flow rate Varies for each support type*
Maximum operating pressure 1, 5, and 10 ml: 45 psi
50 ml: 40 psi
Fittings Female luer inlet and male luer outlet
Column material Polypropylene
Frit material Polyethylene (HDPE)
Dimensions 1 ml — 40 mm length x 5.6 mm inner diameter
5 ml — 40 mm length x 12.6 mm inner diameter
10 ml — 80 mm length x 12.6 mm inner diameter**
50 ml — 80 mm length x 28.2 mm inner diameter**

* Recommended flow rates are given for each support type in the instruction manual.
** Available for desalting cartridges only.

Cartridge Comparison

Comparison of Bio-Scale mini cartridges to other affinity columns on the Profinia™ protein purification system. Yield (A) and purity (B) of various proteins purified using either Bio-Scale™ Mini Profinity™ IMAC cartridges () or commercially available prepacked columns HisTrap FF () or HisTrap HP () on the Profinia system. Rec1, 75 kD; Fih1, 37 kD; DHFR, 25 kD; SME1, 11 kD.

To read more click here

Bio-Scale Mini cartridges have a double-wall cartridge design* that provides extra durability and allows easy, reliable runs at pressures up to 45 psi with the aqueous buffers most commonly used for protein separation. The cartridges are prepacked with Bio-Rad's chromatography media for ion exchange, affinity, hydroxyapatite, and fluoroapatite media. Convenient, disposable, and ready to use, these cartridges come in 1 and 5 ml formats that can be used for method scouting or simple purifications (larger 10 and 50 ml desalting cartridges are also available). The simple luer connections can connect easily to any chromatography system (for a column connection guide, refer to bulletin 5326).

The Bio-Scale Mini cartridge protein purification sampler packs offer a quick way to experiment with separation techniques when the protein to be purified has not yet been characterized. With the following sampler packs, a sample can be tested with all the cartridges in a single day.

Bio-Scale Mini Apatite Purification Kit 

CHT ceramic hydroxyapatite and CFT ceramic fluoroapatite have comparable separation characteristics, differing mostly in the pH buffer range in which they perform best. Whereas CHT ceramic hydroxyapatite exhibits pH stability as low as pH 6.5, the fluorine substitution in CFT ceramic fluorapatite extends pH stability to as low as pH 5.6. The Bio-Scale Mini apatite purification kit is a convenient way to evaluate which apatite material provides the optimum chromatographic performance for your application.

Features include:

  • Prepacked columns with CHT ceramic hydroxyapatite and CFT ceramic fluoroapatite for convenient process development
  • Low bed volume allowing minimum requirements for sample and buffer
  • Luer fittings for convenient connection to any chromatographic system
  • Distinct selectivities and different pH ranges

 

Bio-Scale Mini mAb Purification Kit

Maximize your method optimization and parameter screening for monoclonal antibodies with this sampler kit. This convenient process development kit contains cartridges filled with UNOsphere SUPrA affinity, UNOsphere Q, and CHT ceramic hydroxyapatite media to address all your needs for monoclonal capture, intermediate contaminant removal, and polishing. Maximize your downstream process by optimizing your process application using this kit.

Benefits include:

  • Convenient prepacked columns with a simple luer fitting for easy connection to any system
  • Ideal for screening and optimization of purification protocols
  • Reproducible and scalable results

 

Bio-Scale Mini Ion Exchange Sampler Pack

This sampler pack is used to assess and compare the separation characteristics of a variety of Bio-Rad's most popular ion exchange media. It includes an UNOsphere Q cartridge, an UNOsphere S cartridge, a Macro-Prep Q cartridge, a Macro-Prep S cartridge, and a Macro-Prep DEAE cartridge, all in 1 ml formats.

Bio-Scale Mini Affinity Sampler Pack

This sampler pack is used to develop or compare purification schemes using a variety of affinity purification media. The Bio-Scale Mini affinity sampler pack includes a 1 ml Profinity IMAC cartridge, 1 ml Profinity GST cartridge, 1 ml Affi-Prep protein A cartridge, 5 ml DEAE Affi-Gel Blue cartridge, and 5 ml Affi-Gel Blue cartridge.

* U.S. patent 7,308,087 B2.

Bio-Scale™ Mini Ion Exchange Sample Pack

732-4650
Includes one 1 ml cartridge each of UNOsphere™ S, UNOsphere Q, Macro-Prep® High Q, Macro-Prep High S, Macro-Prep DEAE

List Price:   $250.00
Your Price:   Log in
Quantity:   Add to Cart
Add to Hot List   Add to Quote
Bio-Scale Mini Affinity Sampler Pack

732-4651
Includes one 1 ml cartridge each of IMAC and Affi-Prep protein A, one 5 ml cartridge each of DEAE Affi-Gel Blue and Affi-Gel Blue

List Price:   Inquire
Quantity:   Add to Quote
Add to Hot List  
Bio-Scale™ Mini mAb Purification Cartridge Kit

732-4408
UNOsphere SUPrA™ affinity cartridge, UNOsphere™ Q cartridge, CHT™ Type 1, 40 µm cartridge, 1 x 5 ml each

List Price:   $410.00
Your Price:   Log in
Quantity:   Add to Cart
Add to Hot List   Add to Quote
Number Description Options
5584 Bio-Scale Mini Cartridges, Product Information Sheet, Rev B Click to download [ Add to Cart ]
5444 Bio-Scale Mini Profinity IMAC Cartridge Product Information Sheet, Rev A Click to download [ Add to Cart ]
5326 Chromatography Column Connection Guide, Rev A Click to download [ Add to Cart ]
5662 Process Chromatography Applications Laboratory Brochure, Rev B Click to download [ Add to Cart ]