V3 Western Workflow™

print
V3 Western Workflow

Overview

V3 Western Workflow™
Ordering Information
  Mini-PROTEAN® TGX Stain-Free™ Precast Gels
 



 
Resolving
Gel %
8+1-Well
30 µl
10-Well
30 µl
10-Well
50 µl
12-Well
20 µl
15-Well
15 µl
IPG Well/Prep
7 cm IPG Strip/
450 µl
 
7.5%
456-8029 456-8023 456-8024 456-8025 456-8026 456-8021
10%
456-8039 456-8033 456-8034 456-8035 456-8036 456-8031
12%
456-8049 456-8043 456-8044 456-8045 456-8046 456-8041
Any kD™
456-8129 456-8123 456-8124 456-8125 456-8126 456-8121
 
Ordering Information
  Criterion™ TGX Stain-Free™ Gels
 
 
Resolving Gel % 12+2-Well
45 µl
18-Well
30 µl
26-Well
15 µl
Prep+2-Well
800 µl
IPG+1-Well
11 cm IPG Strip
 
7.5% 567-8023 567-8024 567-8025
10% 567-8033 567-8034 567-8035
12% 567-8043 567-8044 567-8045
18% 567-8073 567-8074 567-8075 567-8072 567-8071
4–15% 567-8083 567-8084 567-8085 567-8082 567-8081
4–20% 567-8093 567-8094 567-8095 567-8092 567-8091
8–16% 567-8103 567-8104 567-8105 567-8102 567-8101
10–20% 567-8113 567-8114 567-8115 567-8112 567-8111
Any kD™ 567-8123 567-8124 567-8125 567-8122 567-8121
 

Bio-Rad's V3 Western Workflow is a five-step approach to streamlining your western blotting protocol. The complete V3 workflow incorporates traditional blotting techniques with innovative tools, such as TGX Stain-Free™ precast gels, the Trans-Blot® Turbo™ system, and the ChemiDoc™ MP imager, to quickly check electrophoresis results and blot transfer quality prior to western blotting, simplifying total protein quantitation analysis post-immunodetection to obtain results faster.

5 Steps

  1. Separate proteinsMini-PROTEAN® TGX Stain-Free™ precast gels and Criterion™ TGX Stain-Free™ precast gels offer superior protein separation with fast run times and use standard Tris/glycine running buffers. TGX Stain-Free™ precast gels contain a unique technology formulated into the gel chemistry that enables rapid, high-quality separation of proteins in as little as 15 minutes.
  2. Visualize proteins — Protein separation can be visualized and confirmed using stain-free technology, which covalently binds proteins, after 1 minute of activation on a ChemiDoc MP imager. This allows the immediate visualization of proteins across the whole gel without staining. Stain-free technology is a sensitive, time-saving alternative to traditional Coomassie staining, offering a streamlined workflow.
  3. Transfer proteins — The Trans-Blot Turbo system is a rapid protein transfer apparatus that can reduce transfer protocols to as little as 3 minutes while maintaining high-efficiency protein transfers across a wide range of molecular weights.
  4. Verify protein transfer — The ChemiDoc MP imager paired with stain-free technology enables instant verification of protein transfer.
  5. Validate and quantitate — The ChemiDoc MP imager and Image Lab™ software may be used to validate western blotting data via total protein normalization in conjunction with housekeeping proteins. By normalizing to total protein, stripping and reprobing is no longer necessary. Image Lab software gives quantitative results instead of relative normalization.

V3 Western Workflow

Applications and uses

Bio-Rad’s V3 Western Workflow facilitates speed and validation at each step of a western blotting experiment — from running gels to quantifying proteins. Visit the Applications and Technologies page to learn more about the following:

More information

The V3 Western Workflow is offered in two gel formats, V3 Western Workflow complete system for mini precast gels (#170-8292) and V3 Western Workflow complete system for midi precast gels (#170-8293).

To select the appropriate gel for your application, see the Mini Gel Selection Guide or the Midi Gel Selection Guide.

V3 Western Workflow™ Complete System for Mini Gels

170-8292
ChemiDoc™ MP imager with LEDs and Image Lab™ software, 50 Mini-PROTEAN® TGX Any kD Stain-Free™ 10-well precast gels with SDS-PAGE accessories, Mini-PROTEAN® Tetra cell, Trans-Blot® Turbo™ starter kit, 50 Trans-Blot Turbo PVDF transfer packs for mini gels

List Price:   Inquire
Your Price:   Log in
Quantity:   Add to Cart
Add to Hot List   Add to Quote
V3 Western Workflow™ Complete System for Midi Gels

170-8293
ChemiDoc™ MP imager with LEDs and Image Lab™ software, 50 Criterion™ TGX Stain-Free™ 4–20% 18-well precast gels with SDS-PAGE accessories, Criterion™ cell, Trans-Blot® Turbo™ starter kit, 50 Trans-Blot Turbo PVDF transfer packs for midi gels

List Price:   Inquire
Your Price:   Log in
Quantity:   Add to Cart
Add to Hot List   Add to Quote
Number Description Options
6253 V3 Western Workflow Brochure with ChemiDoc MP Imager, Rev B Click to download [ Add to Cart ]
6264 V3 Western Workflow Protocol Customer Sample, Rev B Click to download [ Add to Cart ]
RP0051 Stain-Free Approach for Western Blotting Click to download
2895 Protein Blotting Guide, Interactive PDF, Rev B Click to download
6133 ChemiDoc MP Brochure, Rev C Click to download [ Add to Cart ]
6039 Trans-Blot Turbo Transfer System Brochure, Rev D Click to download [ Add to Cart ]
6166 Multiplex Fluorescent Blot Detection: A Troubleshooting Guide, Rev A Click to download [ Add to Cart ]
6349 Total Protein Normalization Publications, Rev A Click to download
6350 Housekeeping Protein Normalization Publications, Rev A Click to download
6351 V3 Stain-Free Technology Publications, Rev A Click to download
6359 Avoiding Housekeeping Protein Detection Saturation Protocol, Rev A Click to download
6361 Determining the Appropriate Film Exposure Time Protocol, Rev A Click to download
6362 Determining the Appropriate Sample Load for Western Blots Protocol, Rev A Click to download
6363 Determining the Appropriate Sample Load When Using a Stain-Free V3 Western Workflow Protocol, Rev A Click to download
6366 Validating the Expression Consistency of a Housekeeping Protein Protocol, Rev A Click to download
6376 General Protocol for Western Blotting Protocol, Rev A Click to download
6356 Traditional vs. V3 Western Workflow Click to download
6360 A Method for Greater Reliability in Western Blot Loading Controls: Stain-Free Total Protein Quantitation Click to download