No More Western Blotting Worries: Bio-Rad’s New V3 Western Workflow™ Provides Confidence at Every Step of the Immunoblotting Workflow

Date: 
2012-04-11

V3 Cuts Western Blotting Time in Half

HERCULES, CA — April 11, 2012 — Bio-Rad Laboratories, Inc. launched its V3 Western Workflow, a portfolio of products designed to reassure researchers at every step throughout the immunoblotting workflow. Leveraging stain-free imaging technology, the V3 Western Workflow enables scientists to visualize protein separation, verify protein transfer, and confidently validate blot data via total protein normalization.

The V3 Western Workflow also cuts the traditional western blotting process from two days to one day. From protein separation to protein transfer to load control normalization for quantitative results, Bio-Rad products dramatically shorten time to results while maintaining high performance at each step.

“Instead of two days to do a western blotting experiment from beginning to end, we can see results within a day with the new workflow,” said Dr. Aldrin Gomes, assistant professor at the University of California, Davis.

The V3 Western Workflow consists of five steps, each enabled by Bio-Rad’s family of blotting instruments and/or products:

Five Steps from Separation to Results

  • Protein separation using Criterion™ TGX Stain-Free™ and Mini-PROTEAN® TGX Stain-Free precast gels
  • In-gel protein visualization using ChemiDoc™ MP imaging system
  • Protein transfer to membrane using TransBlot® Turbo™ transfer system
  • Transfer verification using ChemiDoc MP imaging system
  • Western blot validation using ChemiDoc MP imaging system

Steps 1 and 2:  Protein Electrophoresis and Visualization of Separation
Bio-Rad’s Criterion TGX Stain-Free and Mini-PROTEAN TGX Stain-Free precast gels provide researchers with complete electrophoretic separation of protein samples in as little as 15 minutes. The gels include a unique trihalo compound that allows fluorescent detection of proteins in gels or on membranes in one minute when using the stain-free enabled ChemiDoc MP imaging system. Coomassie gel staining methods can take up to two hours to complete.

Steps 3 and 4:  Protein Transfer to Membrane and Verification of Transfer
The Trans-Blot Turbo transfer system facilitates efficient protein transfer across a wide range of molecular weights in as little as three minutes with Bio-Rad’s TGX Stain-Free precast gels. Using the ChemiDoc MP imaging system, researchers can instantly visualize protein transfer prior to blot detection by imaging the membrane. The gel can also be reimaged to establish whether any proteins remain.

“We used the ChemiDoc MP to make sure our gels were transferred without any problems,” said Gomes. “It’s less tedious than Ponceau staining. By doing this, we can proceed with confidence knowing we’re not wasting any antibody.”

Step 5:  Validation of Western Blot
Researchers quantifying western blot experiments traditionally normalize data with housekeeping proteins, which often requires stripping and probing the membrane a second time, or probing with multiple antibodies simultaneously. Both add extra steps to the protocol, consuming reagents, time, and labor. Furthermore, normalizing against housekeeping proteins might produce inaccurate results.

V3 Western Workflow
Bio-Rad's V3 Western Workflow™ reassures researchers at every step throughout the immunoblotting protocol.

Using the stain-free detection option of the ChemiDoc MP system, researchers can quantify total protein for normalization purposes. This stain-free total protein normalization method produces faster quantitative results compared with relative normalization results using housekeeping proteins, which can lead to errors.

For more information on how the V3 Western Workflow can increase your rate of success for western blotting experiments, visit www.bio-rad.com/ad/V3pr.

About Bio-Rad
Bio-Rad Laboratories, Inc. (NYSE: BIO and BIOb) has remained at the center of scientific discovery for more than 50 years, manufacturing and distributing a broad range of products for the life science research and clinical diagnostic markets. The Company is renowned worldwide among hospitals, universities, major research institutions, as well as biotechnology and pharmaceutical companies for its commitment to quality and customer service. Founded in 1952, Bio-Rad is headquartered in Hercules, California, and serves more than 100,000 research and industry customers worldwide through its global network of operations. The Company employs over 7,100 people globally and had revenues exceeding $2 billion in 2011. For more information, visit www.bio-rad.com.

This release contains certain forward-looking statements within the meaning of the Private Securities Litigation Reform Act of 1995 and Section 21E of the Securities Exchange Act of 1934. Forward-looking statements generally can be identified by the use of forward-looking terminology such as, “believe,” “expect,” “may,” “will,” “intend,” “estimate,” “continue,” or similar expressions or the negative of those terms or expressions. Such statements involve risks and uncertainties, which could cause actual results to vary materially from those expressed in or indicated by the forward-looking statements. For further information regarding the Company's risks and uncertainties, please refer to the “Risk Factors” in the Company’s public reports filed with the Securities and Exchange Commission, including the Company’s most recent Annual Report on Form 10-K, Quarterly Reports on Form 10-Q and Current Reports on Form 8-K. The Company cautions you not to place undue reliance on forward-looking statements, which reflect an analysis only and speak only as of the date hereof. Bio-Rad Laboratories, Inc., disclaims any obligation to update these forward-looking statements.

For more information contact:
Ryan Short
Bio-Rad Laboratories, Inc.
800-876-3425
Ryan_Short@bio-rad.com

Ken Li
Chempetitive Group
312-997-2436 x 109
kli@chempetitive.com