Liquichek Urine Chemistry Control

Liquichek Urine Chemistry Control

Overview

Liquid control ideal for monitoring the precision of urine chemistry testing procedures

Read full description

Description

Description

Unity Software Solutions

Unity Software Solutions

Unity helps laboratories around the world optimize QC practices and make decisions in real time with tools
to create QC strategies and
manage risk.

Unity Data Management »

 

Peer Reporting Program

Peer Reporting Program

The Unity Interlaboratory Peer Program provides a cost-effective opportunity to compare and improve QC performance by utilizing data generated from thousands of laboratories worldwide.

Learn more about Unity »

Liquichek Urine Chemistry Control is an assayed, liquid, human urine-based control designed to monitor the precision of urine chemistry testing procedures, including analytes hCG, Amylase, and Creatinine. The control is available in two configurations, a standard vial and a compact vial with barcode. The compact vial is compatible with applicable automated platforms such as Siemens Dimension Vista and Abbott Alinity while the 2D barcode allows for quick and easy QC setup.

Liquichek Urine Chemistry Control is available in two levels, which allows for monitoring of test system reliability, and offers assayed values for urine tests commonly performed on chemistry analyzers and for some manual methods.

 

Order Online—Reserve Your Lots Today

QC Lot reservation and schedule delivery—Now available with online ordering.

Login or Register on My Bio-Rad today and start ordering and reserving »

 

Features

  • Consolidated menu of analytes—Contains multiple analytes, including hCG for monitoring urine chemistry testing
  • Patient-like material—Liquid, human urine-based control
  • Multiple levels—Bilevel control offers monitoring of increased assay range
  • Extensive value assignment listings— Allows for use of a wide range of testing methods on most major analyzer systems to help in monitoring the precision of multiple test procedures and improve confidence in patient test results
  • Ease of use—Ready-to-use liquid state offers the convenience of not needing to reconstitute
  • Long shelf life—Reduces crossover studies which helps simplify workflow
  • Largest peer group—Connect with over 29,000 labs worldwide and help you confidently report patients results

 

Storage & Stability

Configuration Stability Shelf life Levels Format
10 mL 30 day open-vial stability at 2-8°C 2 year shelf life at 2-8°C 1, 2 & Bilevel MiniPak Standard vial
2.5 mL 30 day open-vial stability at 2-8°C 2 year shelf life at 2-8°C 1, 2 & Bilevel MiniPak Compact vial

 

Analytes

    • Amylase
    • Calcium
    • Chloride
    • Cortisol¹
    • Creatinine
    • Glucose
    • Magnesium
    • Microalbumin
    • Osmolality¹
    • pH¹
    • Phosphorus
    • Potassium
    • Pregnancy/hCG (Qualitative)¹
    • Protein (Total)
    • Sodium
    • Specific Gravity¹
    • Urea¹
    • Urea Nitrogen (BUN)
    • Uric Acid

¹ Not included in compact vial format.

Refer to My eInserts or the product insert (IFU) of currently available lots for specific analyte and stability claims, assigned values or additional data charts.

 

Related Products

Lyphochek Quantitative Urine Control
Liquichek Microalbumin Control
InteliQ Controls
Urinalysis Controls
Serum Chemistry Controls

 

Frequently Asked Questions

After use, how long can the control product be left out before return to refrigerator?
Typically, if the product has been stored refrigerated, allow the product to reach room temperature (18°C to 25°C) before use (specific time limitations may apply, depending on the product). For optimal analyte stability, promptly return the product to the recommended storage temperature after each use.
What type of water should be used to reconstitute lyophilized control products?
Typically, distilled or deionized water is used. Please refer to the product insert (IFU) for product specific reconstitution instructions.
How long should the reconstituted control remain at room temperature prior to use?
Upon reconstitution, the stopper should be replaced and the product should be allowed to stand at room temperature for the time period indicated in the package insert. Prior to use, gently swirl the vial to ensure homogeneity. Refer to the procedure section of the product insert (IFU) for product-specific handling instructions.
How long should frozen liquid controls sit at room temperature in order to thaw?
Typically, the frozen product should be allowed to thaw at room temperature (18°C to 25°C) for the time indicated in the product insert (IFU) or until completely thawed prior to use. The product vial should be swirled gently to ensure homogeneity prior to use. Refer to the procedure section of the product insert (IFU) for product-specific handling instruction.
What are the acceptable limits for room, refrigerator, and freezer temperature?
This information is stated in the product insert (IFU):
  • Room temperature: 18°C to 25°C
  • Refrigerator temperature: 2-8°C
  • Freezer temperature: -20°C to -70°C/-20°C to -50°C for 2.5 mL vial

Most frozen products recommend avoidance of frost-free freezers. There are exceptions, so refer to specific control insert.

Ordering

Ordering

items

Use the filters below to refine results!

Image
397_qsd_uchem_tn.jpg
397

Assayed, liquid human urine based control for urine chemistry analytes including Microalbumin; level 1 of 2
(12 x 10 mL)

Image
398_qsd_uchem_tn.jpg
398

Assayed, liquid human urine based control for urine chemistry analytes including Microalbumin; level 2 of 2
(12 x 10 mL)

Image
395x_qsd_uchem_tn.jpg
395X

Assayed, liquid human urine based control for urine chemistry analytes including Microalbumin; bilevel MiniPak
(2 x 10 mL)

Image
qsd_195_tn.jpg
195

A liquid, bilevel control designed to monitor the precision of urine chemistry testing procedures. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity; level 1 of 2 (12 x 2.5 mL)

Image
qsd_196_tn.jpg
196

A liquid, bilevel control designed to monitor the precision of urine chemistry testing procedures. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity; level 2 of 2 (12 x 2.5 mL)

Image
qsd_198x_tn.jpg
198X

A liquid, bilevel control designed to monitor the precision of urine chemistry testing procedures. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity; bilevel MiniPak (2 x 2.5 mL)

Accessories

Accessories

Image
qsd_98700_tip_screwcap_tn.jpg
987000
Disposable plastic tip accessories for quality controls fitted with a screw cap closure. Enables fluid delivery directly from glass vial. 100/Package.

Documents

Documents

Number Description Options
Q-1214
Bio-Rad Quality Control Products in Compact Vials
[ Add to Cart (Free) ]
Q-1118
Quality Control Products & Services Catalog
[ Add to Cart (Free) ]