A liquid, assayed multi-analyte control designed to monitor the precision of tumor marker testing procedures

Read full description

Description

Description

Unity Software Solutions

Unity Software Solutions

Unity helps laboratories around the world optimize QC practices and make decisions in real time with tools
to create QC strategies and
manage risk.

Unity Data Management »

 

Peer Reporting Program

Peer Reporting Program

The Unity Interlaboratory Peer Program provides a cost-effective opportunity to compare and improve QC performance by utilizing data generated from thousands of laboratories worldwide.

Learn more about Unity »

Liquichek Tumor Marker Control is an assayed, liquid, human-based control designed to monitor the precision of tumor marker testing procedures at clinically relevant levels. This multi-analyte quality control includes very low levels of Prostate-Specific Antigen (PSA) for high-sensitivity test methods and very high levels of cancer antigens and Ferritin. This control is available in two configurations, a standard vial and a compact vial with barcode. The compact vial is compatible with applicable automated platforms such as Siemens Dimension Vista and Abbott Alinity, while the 2D barcode allows for quick and easy QC setup.

Liquichek Tumor Marker Control offers a comprehensive menu of cancer antigen and tumor marker analytes designed to cover a variety of cancer-related disease states, and it can be used on most major testing platforms for cancer screening. The control is available in three levels. Multiple levels allow monitoring of test system reliability.

 

Order Online—Reserve Your Lots Today

QC Lot reservation and schedule delivery—Now available with online ordering.

Login or Register on My Bio-Rad today and start ordering and reserving »

 

Features

  • Consolidated menu of analytes—Contains more than 20 serum proteins and analytes, including cancer antigens and Ferritin for monitoring clinical tumor marker testing
  • Multiple configurations—Standard and compact vials offer ready-to-use convenience, eliminating handling errors
  • Patient-like material—Liquid, human-based control
  • Multiple levels— Trilevel control offers increased assay range monitoring
  • Extensive value assignment listings—Allows for use of a wide range of testing methods on most major integrated immunoassay platforms to help consolidate and streamline workflows
  • Ease of use—Ready-to-use liquid state offers convenience of not needing to reconstitute
  • Long shelf life—Reduces crossover studies which helps simplify workflow

 

Storage & Stability

Configuration Stability Shelf life Levels Format
2 mL 30 day open-vial stability at 2-8°C for most analytes 2 year shelf life when stored frozen at -20°C to -70°C 1, 2, 3 & Trilevel MiniPak Standard vial
2 mL 10 day open-vial stability at 2-8°C for all analytes 2 year shelf life at -20°C to -50°C 1, 2, 3 & Trilevel MiniPak Compact vial

 

Analytes

    • β-2-Microglobulin
    • Alphafetoprotein (AFP)
    • CA 125
    • CA 15-3
    • CA 19-9
    • CA 27.29¹
    • CA 72-4*¹
    • Carcinoembryonic Antigen (CEA)
    • Cyfra 21-1*¹
    • Ferritin
    • hCG
    • HE4¹
    • HER2/neu¹
    • Insulin Growth Factor I (IGF-I)¹
    • PAP¹
    • ProGRP*¹
    • Prolactin
    • PSA
    • PSA (Free)
    • SCC*¹
    • Thyroglobulin (Tg)¹

*International Use Only. Not available for diagnostic use in the United States.

¹ Not included in compact vial format.

Refer to My eInserts or the product insert (IFU) of currently available lots for specific analyte and stability claims.

 

Applications & Use

This product should be treated the same as patient specimens and used in accordance with the instructions accompanying the instrument, kit or reagent.

Using a volumetric pipette or equivalent, reconstitute each vial with 2.0 mL of distilled or deionized water. Replace the stopper and allow this product to stand for approximately 15 minutes, swirling occasionally. Gently swirl the vial several times to ensure homogeneity. After each use, promptly replace the stopper and return to 2-8°C storage.

If the reconstituted product has been stored refrigerated, allow it to reach room temperature (18°C to 25°C) before use. Before sampling, gently swirl the vial several times. If the reconstituted product has been stored frozen, allow it to reach room temperature (18°C to 25°C) before use. Before sampling, gently swirl the vial several times to ensure homogeneity.

 

How it Works

 

barcoded compact vial workflow

 

Related Products

Immunoassay Controls
Immunology/Protein Controls 
InteliQ Controls

 


Frequently Asked Questions

After use, how long can the control product be left out before return to refrigerator?
Typically, if the product has been stored refrigerated, allow the product to reach room temperature (18°C to 25°C) before use (specific time limitations may apply, depending on the product). For optimal analyte stability, promptly return the product to the recommended storage temperature after each use.
How long should frozen liquid controls sit at room temperature in order to thaw?
Typically, the frozen product should be allowed to thaw at room temperature (18°C to 25°C) for the time indicated in the product insert (IFU) or until completely thawed prior to use. The product vial should be swirled gently to ensure homogeneity prior to use. Refer to the procedure section of the product insert (IFU) for product-specific handling instruction.
What are the acceptable limits for room, refrigerator, and freezer temperature?
This information is stated in the product insert (IFU):
  • Room temperature: 18°C to 25°C
  • Refrigerator temperature: 2-8°C
  • Freezer temperature: -20°C to -70°C/-20°C to -50°C for 2.5 mL vial

Most frozen products recommend avoidance of frost-free freezers. There are exceptions, so refer to specific control insert.

Ordering

Ordering

items

Use the filters below to refine results!

Image
547_qsd_litmk_tn.jpg
547
Assayed, liquid control, prepared from human source material for monitoring the precision of cancer antigen and tumor marker assays; level 1 of 3 (6 x 2 mL)
Image
548_qsd_litmk_tn.jpg
548
Assayed, liquid control, prepared from human source material for monitoring the precision of cancer antigen and tumor marker assays; level 2 of 3 (6 x 2 mL)
Image
549_qsd_litmk_tn.jpg
549
Assayed, liquid control, prepared from human source material for monitoring the precision of cancer antigen and tumor marker assays; level 3 of 3 (6 x 2 mL)
Image
548x_qsd_litmk_tn.jpg
548X
Assayed, liquid control, prepared from human source material for monitoring the precision of cancer antigen and tumor marker assays; trilevel MiniPak (3 x 2 mL)
Image
qsd_27114_liqtumormarkervista_tn.jpg
27114

Assayed, liquid control, prepared from human source material for monitoring the precision of cancer antigen and tumor marker assays. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity; level 1 of 3 (6 x 2 mL)

Image
qsd_27115_liqtumormarkervista_tn.jpg
27115

Assayed, liquid control, prepared from human source material for monitoring the precision of cancer antigen and tumor marker assays. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity; level 2 of 3 (6 x 2 mL)

Image
qsd_27116_liqtumormarkervista_tn.jpg
27116

Assayed, liquid control, prepared from human source material for monitoring the precision of cancer antigen and tumor marker assays. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity; level 3 of 3 (6 x 2 mL)

Image
qsd_27115X_liqtumormarkervista_tn.jpg
27115X

Assayed, liquid control, prepared from human source material for monitoring the precision of cancer antigen and tumor marker assays. Compact, barcoded vial compatible with automated platforms such as Siemens Dimension Vista and Abbott Alinity; trilevel MiniPak (3 x 2 mL)

Accessories

Accessories

Image
qsd_98700_tip_screwcap_tn.jpg
987000
Disposable plastic tip accessories for quality controls fitted with a screw cap closure. Enables fluid delivery directly from glass vial. 100/Package.

Documents