Foresight Prepacked Chromatography Columns

Foresight Prepacked Chromatography Columns

Overview

Foresight columns are prepacked with a range of Bio-Rad process chromatography resins. They have a robust design that provides convenience and reliability for process scientists and may be used for resin screening experiments and/or small-scale method development.

Read full description

Description

Description

Foresight Prepacked Chromatography Columns have a robust design that provides convenience and reliability for process scientists. Foresight Columns may be used for media screening experiments and/or small-scale method development. Through design of experiments (DOE) utilizing Foresight Columns, an operational window can be defined to aid in developing a quality by design (QbD) process. The design of the column ensures leak-free operation at pressures up to 30 bar.* The columns allow faster, more convenient experimental setups.

Features and Benefits

  • Convenience — prepacked column is ready for equilibration in the buffer of choice. Multiple bed heights are available with the same column diameter that allow straightforward comparative evaluation
  • Reliability — each column is individually packed under optimum compression, ensuring consistent experimental results

The Foresight Columns Instruction Manual describes how to use Foresight Columns prepacked with Bio-Rad's Chromatography Resins.

Other formats available:

Learn more about Foresight Prepacked Column and Plate formats and applications.

Chromatography Resins Available in Foresight Prepacked Columns and Plates

Chromatography Type
Foresight 1 ml Column
Foresight 5 ml Column
Strong Anion Exchange
7324732
UNOsphere Q Column
7324752
UNOsphere Q Column
Strong Anion Exchange
12007020
Nuvia HP-Q Column
12007021
Nuvia HP-Q Column
Strong Anion Exchange
7324721
Nuvia Q Column
7324741
Nuvia Q Column
Strong Cation Exchange
7324730
UNOsphere S Column
7324750
UNOsphere S Column
Strong Cation Exchange
7324723
Nuvia HR-S Column
7324740
Nuvia HR-S Column
Strong Cation Exchange
7324720
Nuvia S Column
7324740
Nuvia S Column
Metal Affinity
12004038
Nuvia IMAC Ni-Charged Column
12004037
Nuvia IMAC Ni-Charged Column
Mixed-Mode: Hydrophobic Anionic
12007392
Nuvia aPrime 4A Column
12007393
Nuvia aPrime 4A Column
Mixed-Mode: Hydrophobic Cationic
7324722
Nuvia cPrime Column
7324742
Nuvia cPrime Column
Mixed-Mode: Cationic, Metal Affinity
7324735
CHT Type I Column, 40 μm
7324755
CHT Type I Column, 40 μm
Mixed-Mode: Cationic, Metal Affinity
7324736
CHT Type II Column, 40 μm
7324756
CHT Type II Column, 40 μm
Mixed-Mode: Cationic, Metal Affinity
12003150
CHT XT Column, 40 μm
12003149
CHT XT Column, 40 μm
Mixed-Mode: Cationic, Metal Affinity
7324737
MPC Type I Column, 40 μm
7324757
MPC Type I Column, 40 μm

* Please refer to each resins' manual for pressure limitations. Do not exceed the resins' pressure limit during operation of the prepacked column.

Specifications

Specifications

1- and 5-ml Columns
 
Connectors
10–32 fittings
Column material
Polyethylene (HDPE)
Frit material
Polypropylene/polyethylene
Autoclavability
Not autoclavable
Shipping Conditions
 
Ion exchangers
 
  Nuvia™ S, Q and UNOsphere™ S, Q Media
20% ethanol + 150 mM NaCl
CHT™ and MPC™ Media
20% EtOH + 10mM sodium phosphate, pH 6.8
Nuvia cPrime, IMAC, aPrime & UNOsphere SUPrA Media
20% ethanol
1-ml Column
 
Inner diameter, mm
8
Length, mm
20
Maximum pressure, bar (psi)
Follow guidelines for each resin
Recommended flow rate, ml/min (cm/hr)
0.5–1 (59.5–119)
Maximum flow rate, ml/min (cm/hr)
8 (952)
5-ml Column
 
Inner diameter, mm
8
Length, mm
100
Maximum pressure, bar (psi)
Follow guidelines for each resin
Recommended flow rate, ml/min (cm/hr)
2.5–5 (297.5–595)
Maximum flow rate, ml/min (cm/hr)
8 (952)

Ordering

Ordering

items

Use the filters below to refine results!

Image
12004038-foresight-nuvia-ni-charged-imac-1-ml-column-tn.jpg
12004038
Pkg of 1, 1 ml column prepacked with Nuvia IMAC Affinity Chromatography Resin
Image
12004037-foresight-nuvia-ni-charged-imac-5-ml-column-tn.jpg
12004037
Pkg of 1, 5 ml column prepacked with Nuvia IMAC Affinity Chromatography Resin
Image
12007020-tn.jpg
12007020
1 ml, column prepacked with Nuvia HP-Q Strong Anion Exchange Chromatography Media, 50 µm particle size
Image
12007021-th.jpg
12007021
Pkg of 1, 5 ml, column prepacked with Nuvia HP-Q Strong Anion Exchange Chromatography Media, 50 µm particle size
Image
12003150-thumb.jpg
12003150
Pkg of 1, 1 ml column prepacked with CHT Ceramic Hydroxyapatite XT Mixed-Mode Chromatography Media, 40 µm particle size
Image
12003149-thumb.jpg
12003149
Pkg of 1, 5 ml column prepacked with CHT Ceramic Hydroxyapatite XT Mixed-Mode Chromatography Media, 40 µm particle size
Image
foresight-mpc-type-I-column-40-microm-1-ml-732-4737-thumb.jpg
7324737
Pkg of 1, 1 ml, column prepacked with MPC Type I Mixed-Mode Chromatography Resin, 40 µm particle size
Image
foresight-mpc-type-I-column-40-microm-5-ml-732-4757-thumb.jpg
7324757
Pkg of 1, 5 ml, column prepacked with MPC Type I Mixed-Mode Chromatography Resin, 40 µm particle size
Image
foresight-unosphere-supra-column-1-ml-732-4729-thumb.jpg
7324729

Pkg of 1, 1 ml, column prepacked with UNOsphere SUPrA Affinity Chromatography Resin

Image
foresight-unosphere-supra-column-5-ml-732-4749-thumb.jpg
7324749

Pkg of 1, 5 ml, column prepacked with UNOsphere SUPrA Affinity Chromatography Resin

Image
foresight-cht-type-1-732-4735-thumb.jpg
7324735
Pkg of 1, 1 ml, column prepacked with CHT Ceramic Hydroxyapatite Type I Multimodal Chromatography Media, 40 μm particle size
Image
foresight-cht-type-1-5ml-732-4755-thumb.jpg
7324755
Pkg of 1, 5 ml, column prepacked with CHT Ceramic Hydroxyapatite Type I Multimodal Chromatography Media, 40 μm particle size
Image
foresight-cht-type-2-732-4736-thumb.jpg
7324736
Pkg of 1, 1 ml, column prepacked with CHT Ceramic Hydroxyapatite Type II Multimodal Chromatography Media, 40 μm particle size
Image
foresight-cht-type-2-5ml-732-4756-thumb.jpg
7324756
Pkg of 1, 5 ml, column prepacked with CHT Ceramic Hydroxyapatite Type II Multimodal Chromatography Media, 40 μm particle size

Fittings

Fittings

Documents

Documents

Number Description Options
10024831
Instruction Manual, Foresight™ Chromatography Media Columns 1 and 5 ml, Rev A
6297
Foresight Prepacked Plates and Columns Product Information Sheet
10027565
Instruction Manual, Foresight™ RoboColumn Units 200 and 600 µl, Rev A
10024413
Instruction Manual, Foresight™ Chromatography Media Filter Plates, Rev A
D116698
Instruction Manual, Nuvia™ IMAC Resin
10023853
Instruction Manual, Nuvia™ cPrime™ Hydrophobic Cation Exchange Resin
10033316
Instruction Manual, Nuvia HR-S Strong Cation Exchange Media, Rev A
4110109
Instruction Manual, UNOsphere Q and S Ion Exchange Media, Rev C
10014430
Instruction Manual, UNOsphere SUPrA™ Affinity Chromatography Media, Rev C
6086
Ceramic Hydroxyapatite Application Guide for Process Development and Scale-Up
[ Add to Cart (Free) ]
6498
Laboratory-Scale Protein Purification — Column Selection Guide
6982
Mixed-Mode Resins/Media Selection Guide
[ Add to Cart (Free) ]
6983
Native and Recombinant Protein Purification Resins/Media Selection Card
6786
Monoclonal Antibody Purification Resin Selection Card, Ver A
6789
IgG Polyclonal Antibody Purification Resin Selection Card, Ver A
6791
Virus Purification Resin Selection Card, Ver A
6792
Aggregate Purification Resin Selection Card, Ver A
6530
Protein Purification Workflow Development Using the Bio-Rad NGC Chromatography System and Stain-Free Gel Technology Application Note
[ Add to Cart (Free) ]
6719
Development of an Efficient Manufacturing Process for Adenovirus, Ver A