BioLogic LP System

Print

Overview

BioLogic LP Data View Software
BioLogic LP System Dataview Software

Easy-to-use LP Data View software for the BioLogic LP system transforms any computer running a Windows operating system into a chart recorder. However, far more flexible than a chart recorder, LP Data View allows complete freedom to rescale chromatogram axes both during and after a run, to multitask during chromatogram data capture, and to print using any dedicated or networked printer.

BioLogic LP Valves

Three valve types:

  • Buffer selection and automated Sample Loading Valve (SV-5): allows selective control of up to five buffers and automatic injection of large-volume samples
  • Manual Sample Injection Valve (MV-6): accommodates user made loops of any volume
  • Fraction collection/Column Bypass valve (SV-3): a two position solenoid valve directs effluent flow from the column to a bypass position or from the fraction collector to a waste position. Also compatible with the Econo gradient pump and Model EP-1 Econo pump

 

Model 2110 Fraction Collector
Model 2110 Fraction Collector

The Model 2110 fraction collector is a carousel-type fraction collector capable of collecting from 1 drop (~50 µL) to 9 mL fractions in 80 test tubes or microtubes. Collection can be in time, drop, or volume mode when connected to the Model EP-1 Econo pump, BioLogic LP system, or BioLogic DuoFlow system. Small chromatography columns can be mounted to drop forming arm to minimize dead volume. It is coldroom compatible.

BioFrac Fraction Collector
BioFrac Fraction Collector

The BioFrac fraction collector can be used for basic or complex fraction collection schemes at flow rates <100 mL/min. Available stand-alone or with the BioLogic DuoFlow and LP systems, this fraction collector offers flexibility with numerous collection rack options ranging from an icebath/microplate rack to a prep-20 preparative scale rack for large volume collection. Collection in time, drop, or volume mode with peak detection, time windows, or a combination of both.

Econo Gradient Pump
Econo Gradient Pump

Suited for low pressure protein purification, this standalone peristaltic pump is capable of isocratic and gradient applications. The two-channel bidirectional peristaltic pump is capable of flow rates from 0.002–40 mL/min. The system can be hooked up to the Model 2110 or BioFrac fraction collector and is coldroom compatible.

The BioLogic LP low-pressure chromatography system is used for biomolecule purification. Its compact design minimizes the workspace required in the coldroom or on the laboratory bench. The system includes both 254 and 280 nm filters for nucleic acid and protein detection, and a conductivity cell to monitor gradient progress.

The system houses a peristaltic pump with a flow rate range of 0.05–40 ml/min (20 ml/min per channel; dual-channel peristaltic pump) and maximum backpressure of 30 psi (0.2 MPa); the system is compatible with Econo-Column low-pressure chromatography columns, UNOsphere, Bio-Gel P, and Macro-Prep chromatography media, Bio-Scale Mini and Econo-Pac cartridges, Amersham HiTrap cartridges, SOURCE media, and all other low-pressure chromatography media. Addition of an SV-5 buffer select valve allows selection of up to 5 buffers and automated sample separation and loading of large sample volumes.

The system can collect into eighty 13 x 100 mm tubes or microtubes using the Model 2110 fraction collector, or collect into virtually any size container, from microplates to carboys, using the BioFrac fraction collector. In addition, the BioLogic LP system supports the use of many collectors from other manufacturers.

The BioLogic LP system has IEC 61010 safety certification.

LP Data View software captures data, multitasks, and prints data from any computer that runs on Windows 95, 98, Me, NT version 4.0, 2000, or XP operating systems. The system stores up to 50 methods; each method can include up to 50 pump steps and 50 fraction collection steps.

Pump  
   Flow range 0.1–40 ml/min
   Maximim counterpressure 30 psi (2 bar)
   Gradient formation Solenoid-activated proportioning valve
Mixer volume: 750 µl
Detection Performance  
   UV Single channel, 280/254 nm with auto zero
Detection range: 0.001–2 AUFS
   Conductivity Detection range: 0.5–500 mS/cm FS
Temperature Range 4–40°C
Sample Loading Manual loop fill
Automatic loading through SV-5 buffer select valve
Technical Specifications BioLofic LP System
Flow rate limit 20 ml/min per channel; dual-channel peristaltic pump
Pressure limit 30 psi (0.2 MPa)
UV detection 254 and 280 nm filters; 2 mm flow cell
Conductivity Standard
Buffer selection/large sample loading Optional SV-5 buffer-select valve, Model EP-1 Econo pump or Econo gradient pump
Sample injection Manual MV-6 valve
General fraction collection BioFrac or Model 2110 fraction collector
Large-volume fraction collection BioFrac fraction collector with optional prep adaptor
Large-volume fraction collection BioFrac or Model 2110 fraction collector
Solvent compatibility All commonly used chromatographic solvents
Operating tempurature 4–40°C
Dimensions (W x D x H) 24 x 33 x 25 cm
(9.5 x 13 x 9.8")
Weight 19 kg (42 lb)
Standard BioLogic LP System

731-8300
100/120 V, low-pressure chromatography system, includes controller, rack, accessory kit, valve/mixer, UV optics, conductivity cell and holder, tubing and fittings, column holder, starter kit

List Price:   $9,528.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
BioLogic LP System With Model 2110 Fraction Collector

731-8302
110/120 V, low-pressure chromatography system, includes standard BioLogic LP system (#731-8300), Model 2110 fraction collector (#731-8120), SV-3 diverter/bypass valve, system cable 1

List Price:   $10,531.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
BioLogic LP System With BioFrac Fraction Collector

731-8304
110/120 V, low-pressure chromatography system, includes standard BioLogic LP system (#731-8300), BioFrac fraction collector (#741-0002), system cables 3 and 15

List Price:   Inquire
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
BioLogic LP System With BioFrac Fraction Collector and LP Data View Software

731-8338
110/120 V, low-pressure chromatography system, includes standard BioLogic LP system, BioFrac fraction collector, LP Data View software, system cables 3 and 15, 25' serial cable

List Price:   Inquire
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
BioLogic LP System With Model 2110 Fraction Collector and LP Data View Software

731-8336
110/120 V, low-pressure chromatography system, includes standard BioLogic LP system, Model 2110 fraction collector, LP Data View software, SV-3 diverter/bypass valve, system cable 1, 25' serial cable

List Price:   Inquire
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
Number Description Options
2038 BioLogic LP System Brochure, Rev B Click to download [ Add to Cart (Free) ]