Bio-Plex Manager™ Software, Security Edition

Bio-Plex Manager™ Software, Security Edition

Overview

Bio-Plex Manager software provides system control, validation, calibration, data acquisition, and data analysis for multiplex assays using the Bio-Plex® 200 and Bio-Plex 3D systems.

Read full description

Description

Description

Ask a Bio-Plex Specialist

Have questions?

We can help you.

Contact an Expert

Bio-Plex Manager Software 6.2, Security Edition provides all of the features of Bio-Plex Manager Software with additional functionality to enable compliance with USFDA regulations specified in Title 21, Part 11, of the Code of Federal Regulations (CFR).

This software works in conjunction with the built-in security features of the Windows 7 and Windows 10 operating systems to provide a secure environment for the maintenance, verification, and tracking of all electronic records generated by the application.

Records include:

  • Protocol and Results files
  • Calibration, validation, and instrument operation logs

The tools provided in the software include:

  • Access controls and authority checks via the use of user-identification codes and passwords
  • Electronic record security via the use of protected directories
  • Time-and-date–stamped audit trails
  • Electronic signature of electronic records (user authentication)

When properly configured and administered, these tools ensure compliance with the rules for secure handling of electronic records as outlined in 21 CFR Part 11.

Bio-Plex Manager 6.2 Software Features:

  • Integrated data transfer to Bio-Plex Data Pro™ Software
  • Convert data from xPONENT output CSV to Bio-Plex Manager results format (required for import to Bio-Plex Data Pro Software)
  • Combined startup, calibration and warm up — now perform only one start-of-day and one end-of-day procedure.

Visit the Bio-Plex Software Resources page to get the latest software updates, information, and standard lot values.

Effortless Productivity

Bio-Plex Manager Software empowers even inexperienced users to simply and quickly achieve proficiency and deliver results.

  • Don't struggle with awkward imitations of Bio-Plex Manager software. Use the proven choice for effortless multiplex experiments
  • Bio-Plex Manager software automates data optimization. Use version 6.2 and become an instant expert
  • Bio-Plex Manager software supports multiple applications and provides an extensive list of data analysis options. Experience the complete flexibility of version 6.2

*Bio-Plex Manager software cannot perform data acquisition, maintenance, and other instrument operation functions on Bio-Plex 3D systems.  It can analyze the results.

Different versions of Bio-Plex Manager software version 6.1 and their applicability

  Purpose Functions
Data Acquisition Instrument Maintenance Protocol Development Data Analysis and Export
Instrument Control Version Instrument operation, data acquistion and analysis
Desktop Version (Single User) Analysis and setup away from instrument    
Network Version (Multiple Concurrent Users) Analysis and setup away from instrument (multiple seats)    
Compatible Systems   Bio-Plex 100 and 200 systems Bio-Plex 100 and 200 systems Bio-Plex 100 and 200 systems Bio-Plex 100, 200, and 3D systems

Specifications

System Minimum Recommendedc
Operating system Windows 7 32-bit or 64-bit Windows 10 Pro 64-bit
Processor speed Pentium 4 or equivalent, 2.8 GHz Intel Core i5, 3.0 GHz or higher
Hard drive space 80 GB 160 GB or higher
Drive 1 DVD-RW drive 1 DVD-RW drive
RAM 1 GB 4 GB or more
Screen resolution 1280 x 1024 with 24-bit true-color mode 1280 x 1024 with 24-bit true-color mode
Ports for connecting to Readers manufactured after November 2015 (required for Instrument Control license only) 1 USB port 1 USB 2.0 port
Ports for connecting to Readers manufactured before November 2015 (required for Instrument Control license only) 1 RS232 serial port and 1 USB port 1 RS232 serial port and 1 USB 2.0 port
Port for connecting the Hasp key 1 USB port 1 USB 2.0 port
Other software
  • Internet Explorer 6.0 or higher
  • Microsoft Excel 2010 or higher
  • PDF Reader
  • Microsoft Edge
  • Microsoft Excel 16

Ordering

Ordering

items

Use the filters below to refine results!

Image
171-BPM6_tn.gif
171SCRT00
Instrument control license for upgrading standard software to security version 6.2, supports instrument control and data acquisition, for use with the Bio-Plex® system, allows U.S. FDA 21 CFR 11 compliance
Image
171-BPM6_tn.gif
171SCRT01
Desktop license for upgrading standard software to security version 6.2, for use with the Bio-Plex® system, allows 21 CFR Part 11 compliance; does not support instrument control and data acquisition
Image
171-BPM6_tn.gif
171SCRT05
5-user desktop license, version 6.2, for use with the Bio-Plex® system, allows 21 CFR Part 11 compliance; does not support instrument control and data acquisition
Image
171-BPM6_tn.gif
171SCRT10
10-user desktop license, version 6.2, for use with the Bio-Plex® system, allows 21 CFR Part 11 compliance; does not support instrument control and data acquisition
Image
171-BPM6_tn.gif
171SCRT25
25-user desktop license, version 6.2, for use with the Bio-Plex® system, allows 21 CFR Part 11 compliance; does not support instrument control and data acquisition
Image
171-BPM6_tn.gif
171SCRT50
50-user desktop license, version 6.2, for use with the Bio-Plex® system, allows 21 CFR Part 11 compliance; does not support instrument control and data acquisition

Download

Download

Bio-Plex Manager™ Software 6.2
SOFT-06-0843_BIOPLEX_V62
Bio-Plex Manager version 6.2 for instrument data evaluation and optimization. Free upgrade for customers using versions 6.0 and 6.1; the protection key for 6.0 and 6.1 supports 6.2. Upgrade kit is required for all versions previous to version 6.1.

Documents

Documents

Number Description Options
6457
The Bio-Plex Success Guide for Multiplex Immunoassays, Rev B
5405
Bio-Plex® Multiplex System Brochure, Ver E
[ Add to Cart (Free) ]
3076
Bio-Plex Care and Maintenance Quick Guide, Rev B
5336
Bio-Plex Suspension Array System Nucleic Acid Analysis Flier, Rev B
3000
Correlation of Bio-Plex Suspension Array Reader Validation With Multiplex Cytokine Assay Performance, Rev A
3022
Fitting Brendan's Five-Parameter Logistic Curve, Rev A
10022815
Instruction Manual, Bio-Plex Manager 6.2 User Guide
2861
Principles of Curve Fitting for Multiplex Sandwich Immunoassays, Rev B
5613
Bio-Plex Manager System Software Brochure, Rev B