PrimePCR™ lncRNA SYBR® Green Assay:STT3A-AS1, Human

PrimePCR Primer Assays for Real-Time PCR oligo primer pair tube for SYBR Green gene expression.

Real-time PCR primer assay designed for SYBR® Green gene expression analysis.

Info:   Same primer pair as used in probe assay qhsaLIP0148143

List Price:    $169.00
Your Price:   Log In
 
Add to Custom Plate

Assay Information

Technology:   qPCR
Assay Type:   SYBR® Green
Application:   lncRNA Expression
Unique Assay ID:   qhsaLID0070903
Assay Design:   intron_spanning
Chromosome Location:   chr11:125573528-125592489question
Amplicon Length:   89
Refseq Transcripts Amplified:   NR_132372
Splice Variants Targeted:   ENST00000530526
LNCipedia Splice Variants Targeted:   STT3A-AS1:1 STT3A-AS1:2

Gene Information

Not Available

Gene Symbol:   STT3A-AS1
Gene Name:   STT3A antisense RNA 1 [Source:HGNC Symbol;Acc:HGNC:44585]
Aliases:   Not Available
RefSeq:   Not Available
Ensembl:   ENSG00000254671
LNCipedia:   STT3A-AS1
Entrez:   105369550
Chromosome Mapping:   Not Available
Gene Strand:   Reverse strand

The below validation information is for the Primer Pair only   Download Validation Data (.pdf)


Products used to generate validation data:

Real-Time PCR Instrument CFX384 Real-Time PCR Detection System
Reverse Transcription Reagent iScript™ Advanced cDNA Synthesis Kit for RT-qPCR
Real-Time PCR Supermix SsoAdvanced™ Universal SYBR® Green Supermix
Experimental Sample qPCR Human Reference Total RNA

Summary Data:

R2 0.999300
y-intercept 36.070000
Efficiency 1.98

Amplification Plot
Amplification of cDNA generated from universal RNA.

Amplification of cDNA generated from universal RNA.

Melt Peak
Melt curve analysis of above amplification.

Melt curve analysis of above amplification.

Standard Curve
Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Number Description Download
10039761 PrimePCR™ Assays Quick Guide, Ver B Click to download