PrimePCR™ Probe Assay: PPM1E, Human

RT

Real-time PCR probe assay designed for gene expression analysis. Probe assays consist of unlabeled PCR primers and a dual labeled fluorescent probe.

List Price:    $255.00
Your Price:   Log In
 

Assay Information

Technology:   qPCR
Assay Type:   Probe
Application:   Gene Expression
Unique Assay ID:   qHsaCIP0030412
Assay Design:   Intron-spanning
Chromosome Location:   17:57050248-57057447question
Amplicon Length:   122
Splice Variants Targeted:   ENST00000308249 ENST00000443121

Gene Information

The protein encoded by this gene is a member of the PP2C family of Ser/Thr protein phosphatases. PP2C family members are known to be negative regulators of cell stress response pathways. This phosphatase was identified as an interacting protein of Rho guanine nucleotide exchange factors (PIX). PIX proteins are regulators of p21/Cdc42/Rac1-activated kinase 1 (PAK1) a protein kinase mediating biological effects downstream of Rho GTPases. This phosphatase has been shown to block the effects of PAK and thus inhibit actin stress fiber breakdown and morphological changes driven by cell division cycle 42 (CDC42). [provided by RefSeq Jul 2008]

Gene Symbol:   PPM1E
Gene Name:   protein phosphatase, Mg2+/Mn2+ dependent, 1E
Aliases:   CaMKP-N, DKFZp781F1422, KIAA1072, POPX1, PP2CH
RefSeq:   NC_000017.10 NG_009298.1 NT_010783.15
Ensembl:   ENSG00000175175
Entrez:   22843
Chromosome Mapping:   17q22

The below validation information is for the Primer Pair only   Download Validation Data (.pdf)


Products used to generate validation data:

Real-Time PCR Instrument CFX384 Real-Time PCR Detection System
Reverse Transcription Reagent iScript™ Advanced cDNA Synthesis Kit for RT-qPCR
Real-Time PCR Supermix SsoAdvanced™ SYBR® Green Supermix
Experimental Sample qPCR Human Reference Total RNA

Summary Data:

R2 0.999300
y-intercept 34.690000
Efficiency 103

Amplification Plot
Amplification of cDNA generated from universal RNA.

Amplification of cDNA generated from universal RNA.

Melt Peak
Melt curve analysis of above amplification.

Melt curve analysis of above amplification.

Standard Curve
Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Number Description Download
10039761 PrimePCR™ Assays Quick Guide, Ver B Click to download
10042030 PrimePCR™ PreAmp Assay Quick Guide, Rev A Click to download
10000088666 Instruction Manual, PrimePCR Assays, Panels, and Controls, Ver G Click to download
10000143205 SARS-CoV-2 Variant Detection RT-PCR Assay Protocol Click to download
3226 PIS_PrimePCR SARS-CoV-2 Single and Multiple Mutation Assays Click to download
10000147102 PrimePCR SARS-CoV-2 Multiple Mutation Assay Protocol Click to download