PrimePCR™ Probe Assay: HOOK1, Human

RT

Real-time PCR probe assay designed for gene expression analysis. Probe assays consist of unlabeled PCR primers and a dual labeled fluorescent probe.

List Price:    $255.00
Your Price:   Log In
 

Assay Information

Technology:   qPCR
Assay Type:   Probe
Application:   Gene Expression
Unique Assay ID:   qHsaCEP0051829
Assay Design:   exonic
Chromosome Location:   1:60299113-60301017question
Amplicon Length:   68
Splice Variants Targeted:   ENST00000455990 ENST00000371208 ENST00000395561

Gene Information

This gene encodes a member of the hook family of coiled-coil proteins which bind to microtubules and organelles through their N- and C-terminal domains respectively. The encoded protein localizes to discrete punctuate subcellular structures and interacts with several members of the Rab GTPase family involved in endocytosis. It is thought to link endocytic membrane trafficking to the microtubule cytoskeleton. Several alternatively spliced transcript variants have been identified but the full-length nature of some of these variants has not been determined. [provided by RefSeq Jul 2008]

Gene Symbol:   HOOK1
Gene Name:   hook homolog 1 (Drosophila)
Aliases:   HK1, MGC10642
RefSeq:   NC_000001.10 NT_032977.9
Ensembl:   ENSG00000134709
Entrez:   51361
Chromosome Mapping:   1p32.1

The below validation information is for the Primer Pair only   Download Validation Data (.pdf)


Products used to generate validation data:

Real-Time PCR Instrument CFX384 Real-Time PCR Detection System
Reverse Transcription Reagent iScript™ Advanced cDNA Synthesis Kit for RT-qPCR
Real-Time PCR Supermix SsoAdvanced™ Universal SYBR® Green Supermix
Experimental Sample qPCR Human Reference Total RNA

Summary Data:

R2 0.999600
y-intercept 35.830000
Efficiency 97

Amplification Plot
Amplification of cDNA generated from universal RNA.

Amplification of cDNA generated from universal RNA.

Melt Peak
Melt curve analysis of above amplification.

Melt curve analysis of above amplification.

Standard Curve
Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Number Description Download
10039761 PrimePCR™ Assays Quick Guide, Ver B Click to download
10042030 PrimePCR™ PreAmp Assay Quick Guide, Rev A Click to download
10000088666 Instruction Manual, PrimePCR Assays, Panels, and Controls, Ver G Click to download
10000143205 SARS-CoV-2 Variant Detection RT-PCR Assay Protocol Click to download
3226 PIS_PrimePCR SARS-CoV-2 Single and Multiple Mutation Assays Click to download
10000147102 PrimePCR SARS-CoV-2 Multiple Mutation Assay Protocol Click to download