PrimePCR™ Probe Assay: SNRPC, Human

RT

Real-time PCR probe assay designed for gene expression analysis. Probe assays consist of unlabeled PCR primers and a dual labeled fluorescent probe.

List Price:    $255.00
Your Price:   Log In
 

Assay Information

Technology:   qPCR
Assay Type:   Probe
Application:   Gene Expression
Unique Assay ID:   qHsaCEP0051312
Assay Design:   exonic
Chromosome Location:   6:34741357-34741460question
Amplicon Length:   74
Splice Variants Targeted:   ENST00000244520 ENST00000374018 ENST00000374017

Gene Information

This gene encodes one of the specific protein components of the U1 small nuclear ribonucleoprotein (snRNP) particle required for the formation of the spliceosome. The encoded protein participates in the processing of nuclear precursor messenger RNA splicing. snRNP particles are attacked by autoantibodies frequently produced by patients with connective tissue diseases. The genome contains several pseudogenes of this functional gene. Alternative splicing results in a non-coding transcript variant.[provided by RefSeq Oct 2009]

Gene Symbol:   SNRPC
Gene Name:   small nuclear ribonucleoprotein polypeptide C
Aliases:   FLJ20302, U1C, Yhc1
RefSeq:   NC_000006.11 NT_007592.15
Ensembl:   ENSG00000124562
Entrez:   6631
Chromosome Mapping:   6p21.31

The below validation information is for the Primer Pair only   Download Validation Data (.pdf)


Products used to generate validation data:

Real-Time PCR Instrument CFX384 Real-Time PCR Detection System
Reverse Transcription Reagent iScript™ Advanced cDNA Synthesis Kit for RT-qPCR
Real-Time PCR Supermix SsoAdvanced™ Universal SYBR® Green Supermix
Experimental Sample qPCR Human Reference Total RNA

Summary Data:

R2 0.999300
y-intercept 37.410000
Efficiency 93

Amplification Plot
Amplification of cDNA generated from universal RNA.

Amplification of cDNA generated from universal RNA.

Melt Peak
Melt curve analysis of above amplification.

Melt curve analysis of above amplification.

Standard Curve
Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Number Description Download
10039761 PrimePCR™ Assays Quick Guide, Ver B Click to download
10042030 PrimePCR™ PreAmp Assay Quick Guide, Rev A Click to download
10000088666 Instruction Manual, PrimePCR Assays, Panels, and Controls, Ver G Click to download
10000143205 SARS-CoV-2 Variant Detection RT-PCR Assay Protocol Click to download
3226 PIS_PrimePCR SARS-CoV-2 Single and Multiple Mutation Assays Click to download
10000147102 PrimePCR SARS-CoV-2 Multiple Mutation Assay Protocol Click to download