PrimePCR™ Probe Assay: PRX, Human

RT

Real-time PCR probe assay designed for gene expression analysis. Probe assays consist of unlabeled PCR primers and a dual labeled fluorescent probe.

List Price:    $255.00
Your Price:   Log In
 

Assay Information

Technology:   qPCR
Assay Type:   Probe
Application:   Gene Expression
Unique Assay ID:   qHsaCEP0024687
Assay Design:   Exonic
Chromosome Location:   19:40900337-40900479question
Amplicon Length:   113
Splice Variants Targeted:   ENST00000324001 ENST00000341562 ENST00000291825

Gene Information

This gene encodes a protein involved in peripheral nerve myelin upkeep. The encoded protein contains 2 PDZ domains which were named after PSD95 (post synaptic density protein) DlgA (Drosophila disc large tumor suppressor) and ZO1 (a mammalian tight junction protein). Two alternatively spliced transcript variants have been described for this gene which encode different protein isoforms and which are targeted differently in the Schwann cell. Mutations in this gene cause Charcot-Marie-Tooth neuoropathy type 4F and Dejerine-Sottas neuropathy. [provided by RefSeq Jul 2008]

Gene Symbol:   PRX
Gene Name:   periaxin
Aliases:   CMT4F, KIAA1620
RefSeq:   NC_000019.9 NG_007979.1 NT_011109.16
Ensembl:   ENSG00000105227
Entrez:   57716
Chromosome Mapping:   19q13.2

The below validation information is for the Primer Pair only   Download Validation Data (.pdf)


Products used to generate validation data:

Real-Time PCR Instrument CFX384 Real-Time PCR Detection System
Reverse Transcription Reagent iScript™ Advanced cDNA Synthesis Kit for RT-qPCR
Real-Time PCR Supermix SsoAdvanced™ SYBR® Green Supermix
Experimental Sample qPCR Human Reference Total RNA

Summary Data:

R2 0.999700
y-intercept 35.270000
Efficiency 98

Amplification Plot
Amplification of cDNA generated from universal RNA.

Amplification of cDNA generated from universal RNA.

Melt Peak
Melt curve analysis of above amplification.

Melt curve analysis of above amplification.

Standard Curve
Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Number Description Download
10039761 PrimePCR™ Assays Quick Guide, Ver B Click to download
10042030 PrimePCR™ PreAmp Assay Quick Guide, Rev A Click to download
10000088666 Instruction Manual, PrimePCR Assays, Panels, and Controls, Ver G Click to download
10000143205 SARS-CoV-2 Variant Detection RT-PCR Assay Protocol Click to download
3226 PIS_PrimePCR SARS-CoV-2 Single and Multiple Mutation Assays Click to download
10000147102 PrimePCR SARS-CoV-2 Multiple Mutation Assay Protocol Click to download