PrimePCR™ SYBR® Green Assay: MACF1, Human

PrimePCR Primer Assays for Real-Time PCR oligo primer pair tube for SYBR Green gene expression

Real-time PCR primer assay designed for SYBR® Green gene expression analysis.

Info:   Same primer pair as used in probe assay qHsaCEP0039234

List Price:    $174.00
Your Price:   Log In
 
Add to Custom Plate

Assay Information

Technology:   qPCR
Assay Type:   SYBR® Green
Application:   Gene Expression
Unique Assay ID:   qHsaCED0036510
Assay Design:   exonic
Chromosome Location:   1:39945558-39945666question
Amplicon Length:   79
Splice Variants Targeted:   ENST00000567887 ENST00000372915 ENST00000361689 ENST00000564288 ENST00000372925 ENST00000289893 ENST00000360115 ENST00000446276 ENST00000442046 ENST00000422234 ENST00000545844 ENST00000317713 ENST00000539005

Gene Information

The protein encoded by this gene belongs to the plakin family of cytoskeletal linker proteins. This protein family forms bridges between different cytoskeletal elements through specialized modular domains. The encoded protein is one of the largest size proteins identified in human cytoskeletal proteins. It has functional actin and microtubule binding domains and it appears to stabilize actin at sites where microtubules and microfilaments meet. It may function in microtubule dynamics to facilitate actin-microtubule interactions at the cell periphery and to couple the microtubule network to cellular junctions. Alternatively spliced transcript variants encoding distinct isoforms have been described. [provided by RefSeq Jul 2008]

Gene Symbol:   MACF1
Gene Name:   microtubule-actin crosslinking factor 1
Aliases:   ABP620, ACF7, FLJ45612, FLJ46776, KIAA0465, KIAA1251, MACF, OFC4
RefSeq:   NC_000001.10 NT_032977.9
Ensembl:   ENSG00000127603
Entrez:   23499
Chromosome Mapping:   1p32-p31

The below validation information is for the Primer Pair only   Download Validation Data (.pdf)


Products used to generate validation data:

Real-Time PCR Instrument CFX384 Real-Time PCR Detection System
Reverse Transcription Reagent iScript™ Advanced cDNA Synthesis Kit for RT-qPCR
Real-Time PCR Supermix SsoAdvanced™ SYBR® Green Supermix
Experimental Sample qPCR Human Reference Total RNA

Summary Data:

R2 0.997200
y-intercept 35.150000
Efficiency 105

Amplification Plot
Amplification of cDNA generated from universal RNA.

Amplification of cDNA generated from universal RNA.

Melt Peak
Melt curve analysis of above amplification.

Melt curve analysis of above amplification.

Standard Curve
Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Number Description Download
10039761 PrimePCR™ Assays Quick Guide, Ver B Click to download