ProteinChip SELDI system qualification and calibration kits ensure that the ProteinChip SELDI reader, Personal or Enterprise edition, is operating at optimal conditions.
Read full description

Description

Description

ProteinChip SELDI system qualification and calibration kits ensure that the ProteinChip SELDI reader, Personal or Enterprise edition, is operating at optimal conditions. These kits improve the reproducibility and reliability of your SELDI data using the same products and techniques that are used for testing by Bio-Rad quality control and system service teams. The kits use special ProteinChip arrays developed specifically to test and calibrate the ProteinChip SELDI reader. These unique arrays are prespotted with matrix and standards and are ready to use.

Use the qualification and calibration kits to:

  • Stabilize the reader's detector output over time with automatic reader adjustments using the ProteinChip detector calibration array
  • Satisfy requirements for regulated environments using the ProteinChip operational qualification (OQ) kit
  • Ensure valid data collection by qualifying the reader on a regular basis using the ProteinChip OQ kit or the ProteinChip system check kit

ProteinChip Detector Calibration Kit

The ProteinChip detector calibration kit includes a ProteinChip detector calibration array, which provides data that the ProteinChip SELDI reader uses to automatically adjust the detector voltage. Adjustments help to maintain a constant gain, stabilizing the output over the detector's lifetime.

ProteinChip OQ Kit

The ProteinChip OQ kit is designed for use in regulated laboratories. Use this kit to generate reports that show reader compliance to nine operational specifications for sensitivity, resolution, and mass accuracy. The ProteinChip OQ kit includes ProteinChip detector calibration arrays to automatically adjust and help stabilize the detector's output over time. Each kit delivers 12 weeks of testing and calibration.

ProteinChip System Check Kit

The ProteinChip system check kit generates reports that show reader compliance to four operational specifications for sensitivity and resolution.

ProteinChip Peptide Mass Calibration Kit

The ProteinChip peptide mass calibration kit performs mass calibrations using an array prespotted with seven peptide calibrants. The kit can be used multiple times to ensure proper instrument mass accuracy.

[ Add to Cart ]

Ordering

Ordering

items

Use the filters below to refine results!

Image
c70-00080_tn.jpg
(Discontinued) ProteinChip® OQ Kit
C7000080
Operational qualification kit, contains 2 ProteinChip detector calibration arrays, 6 detector qualification arrays, 2 peptide standard arrays, and instrument protocols
Image
c70-00081_tn.jpg
C7000081
Kit contains 1 ProteinChip detector calibration array, 1 detector qualification array, 1 peptide standard array, and instrument protocols

Documents

Documents

Number Description Options
5530
ProteinChip SELDI System Brochure, Rev A
5602
ProteinChip SELDI System Qualification and Calibration Kits Product Information Sheet, Rev B
10010680
Instruction Manual, ProteinChip OQ Kit and Documentation, Rev A
10010681
Instruction Manual, ProteinChip System Check Kit, Rev A
10010682
Instruction Manual, ProteinChip Detector Calibration Kit, Rev A