Liquichek Cardiac Markers Plus Control

Liquichek Cardiac Markers Plus Control

Overview

A comprehensive cardiac assessment control with higher Troponin I & T values for non-high sensitivity assays

Read full description

Description

Description

Unity Software Solutions

Unity Software Solutions

Unity helps laboratories around the world optimize QC practices and make decisions in real time with tools
to create QC strategies and
manage risk.

Unity Data Management »

 

Peer Reporting Program

Peer Reporting Program

The Unity Interlaboratory Peer Program provides a cost-effective opportunity to compare and improve QC performance by utilizing data generated from thousands of laboratories worldwide.

Learn more about Unity »

Liquichek Cardiac Markers Plus Control is an assayed, liquid, human serum-based control designed to monitor the precision of non-high sensitivity Troponin I and T assays. This comprehensive cardiac assessment control offers higher Troponin I and T values and assayed values for multiple analytes including BNP, NT-pro-BNP and hs-CRP.

The control is available in three levels, which allows for monitoring test system reliability.

 

Order Online—Reserve Your Lots Today

QC Lot reservation and schedule delivery—Now available with online ordering.

Login or Register on My Bio-Rad today and start ordering and reserving »

 

Features

  • Consolidated menu of analytes—Contains multiple analytes, including Troponin I and T at higher levels, for non-high sensitivity Troponin testing
  • Patient-like materials—Liquid, human serum-based control
  • Multiple levels—Clinically relevant targets and ranges to help monitor the precision of test methods
  • Extensive value assignment listings—Allows for use of a wide range of testing methods on most major analyzer systems to help compare data from multiple test platforms and improve confidence in patient test results
  • Ease of use—Ready-to-use liquid state offers the convenience of not needing to reconstitute
  • Long shelf life—Reduces crossover studies which helps simplify workflow

 

Storage & Stability

Configuration Stability Shelf life Levels Format
3 mL 20 day open-vial stability
at 2-8°C with exceptions
3 years at -20°C to -70°C 1, 2, 3, Trilevel & Trilevel MiniPak Standard vial

 

Analytes

    • BNP
    • CK (Total)
    • CK-MB Isoenzyme
    • CRP
    • Digitoxin
    • Homocysteine*
    • Myoglobin
    • NT-proBNP
    • Troponin I
    • Troponin T

* No claim is made for expected values or stability.


Refer to My einserts or the product insert (IFU) of currently available lots for specific analytes and stability claims.

 

Application & Use

This product should be treated the same as patient specimens and used in accordance with the instructions accompanying the instrument, kit or reagent.

Allow the frozen product to thaw at room temperature (18°C to 25°C) for approximately 30 minutes or until completely thawed prior to use. Before sampling, gently swirl the vial several times to ensure homogeneity. Store the thawed product at 2-8°C.

If the product has been stored refrigerated, allow it to reach room temperature (18°C to 25°C) before use. Gently swirl the vial several times to ensure homogeneity. After each use promptly replace the stopper and return to 2-8°C storage.

To prepare aliquot samples, allow the control vial to thaw as described above. Gently swirl the vial several times to ensure homogeneity, then dispense the control material into aliquot vials and store at -20°C to -70°C. If sampling aliquot, use it only once. Discard the remaining material.

 

Related Products

InteliQ Cardiac Markers Plus LT
InteliQ Homocysteine Control
Liquichek Cardiac Markers Plus Control LT
Liquichek Cardiac Troponins Control
Liquichek Homocysteine Control
InteliQ Quality Controls

 

Frequently Asked Questions

After use, how long can the control product be left out before return to refrigerator?
Typically, if the product has been stored refrigerated, allow the product to reach room temperature (18°C to 25°C) before use (specific time limitations may apply, depending on the product). For optimal analyte stability, promptly return the product to the recommended storage temperature after each use.
How long should frozen liquid controls sit at room temperature in order to thaw?
Typically, the frozen product should be allowed to thaw at room temperature (18°C to 25°C) for the time indicated in the product insert (IFU) or until completely thawed prior to use. The product vial should be swirled gently to ensure homogeneity prior to use. Refer to the procedure section of the product insert (IFU) for product-specific handling instruction.
What are the acceptable limits for room, refrigerator, and freezer temperature?
This information is stated in the product insert (IFU):
  • Room temperature: 18°C to 25°C
  • Refrigerator temperature: 2-8°C
  • Freezer temperature: -20°C to -70°C/-20°C to -50°C for 2.5 mL vial

Most frozen products recommend avoidance of frost-free freezers. There are exceptions, so refer to specific control insert.

Ordering

Ordering

items

Use the filters below to refine results!

Image
180_qsd_cmpls_tn.jpg
180
Liquid human serum based, comprehensive cardiac assessment control with assayed values for BNP, NT-pro-BNP, and hs-CRP and higher Troponin values trilevel, 2 of each level (6 x 3 mL)
Image
181_qsd_cmpls_tn.jpg
181
Liquid human serum based, comprehensive cardiac assessment control with assayed values for BNP, NT-pro-BNP, and hs-CRP and higher Troponin values (6 x 3 mL)
Image
182_qsd_cmpls_tn.jpg
182
Liquid human serum based, comprehensive cardiac assessment control with assayed values for BNP, NT-pro-BNP, and hs-CRP and higher Troponin values (6 x 3 mL)
Image
183_qsd_cmpls_tn.jpg
183
Liquid human serum based, comprehensive cardiac assessment control with assayed values for BNP, NT-pro-BNP, and hs-CRP and higher Troponin values (6 x 3 mL)
Image
180x_qsd_cmpls_tn.jpg
180X
Liquid human serum based, comprehensive cardiac assessment control with assayed values for BNP, NT-pro-BNP, and hs-CRP and higher Troponin values; trilevel MiniPak, 1 of each level (3 x 3 mL)

Accessories

Accessories

Image
qsd_98700_tip_screwcap_tn.jpg
987000
Disposable plastic tip accessories for quality controls fitted with a screw cap closure. Enables fluid delivery directly from glass vial. 100/Package.

Documents

Documents

Number Description Options
Q-1521
Cardiac Assessment Controls
[ Add to Cart (Free) ]
Q-1118
Quality Control Products & Services Catalog
[ Add to Cart (Free) ]