Foresight™ Chromatography RoboColumn Units

Print
Foresight Chromatography RoboColumn Units

Overview

Foresight™ Prepacked Chromatography Plates and Columns Selection Guide
Foresight Plates

Foresight plates are 96-well filter plates prepacked with 20 µl of chromatography media in each well.

Foresight RoboColumn Units

Foresight RoboColumn units are offered as single rows of eight prepacked microcolumns. Foresight RoboColumn units are ideal for high-throughput (HT) process development.

Foresight Columns

Foresight columns are ideal for confirming the operational window obtained through design of experiments (DOE) in trials with Foresight plates and/or Foresight RoboColumn units.

Applications

Foresight plates can be used for HT evaluation of various binding, elution, or wash conditions for different chromatography media. They can be processed using manual or automated robotic systems, and sample collection may be achieved through centrifugation or vacuum manifold techniques.

Foresight RoboColumn units are fully compatible with robotic liquid handling systems, allowing process developers to perform automated HT parallel media screening and/or small-scale method development. Multiple rows up to 12 can be combined to form a 96-column array, allowing users to evaluate various chromatography media and conditions in parallel.

Foresight columns may be used for media screening experiments and/or small-scale method development. Foresight columns have standard HPLC connections, which make them compatible with the NGC™ chromatography system and other liquid chromatography systems.

Physical Dimensions

Standard 96-well plate format
128 × 86 × 33 mm

1 × 8 row
128 × 86 × 14 mm

8 × 20 mm (1-ml column)
8 × 100 mm (5-ml column)

Working Volume

<900 µl

200–600 µl

1–5 ml

Recommended Flow Rate, cm/hr

N/A

16–1,000

59.5-119 (1-ml column)
287.5-595 (5-ml column)

Maximum Pressure, bar (psi)

N/A

8 (116)

30 (435)

Media Types Available

UNOsphere™ Q, UNOsphere S, UNOsphere Rapid S; Nuvia™ Q, Nuvia S, Nuvia™ cPrime™; CHT™ Type I, CHT Type II

Ordering Information
Foresight™ Filter Plates and Columns Workflow

Foresight chromatography filter plates and columns are prepacked with a range of Bio-Rad’s process chromatography media, offering process scientists convenience and reliability for their high-throughput (HT) experimentation needs. Their robust design allows process scientists to use the prepacked formats through the entire purification development cycle, from HT media screening to small-scale methods development and scale-up optimization.
Learn more


Purification scale-up workflow shows the use of HT screening and design of experiments (DOE) to define an operational window for biomanufacturing.

 

Using High-Throughput (HT) Methods to Accelerate DOE

High-throughput experimentation (HTE) was used in this case study in concert with design of experiments (DOE) methodology to study the mass recovery of a basic therapeutic protein (pI 9.2–9.5) using a hydrophobic cation exchange mixed-mode resin.

Foresight RoboColumn Units are prepacked chromatography microcolumns used for rapid process development. They may be used for parallel media screening experiments and/or small-scale method development. Their design is fully compatible with robotic liquid handling workstations, such as the Freedom EVOware series from Tecan, allowing process developers to perform high-throughput (HT) parallel media screening and experimentation. Through design of experiments (DOE) utilizing Foresight RoboColumn units, an operational window can be defined to aid in biomanufacturing processes.

The design of Foresight RoboColumn Units offers:

  • Convenience — prepacked columns used in conjunction with a robotic liquid handling device allow users to create automated protocols for HT experimentation. The ability to define a design space enables process scientists to develop robust purification processes
  • Reliability — each column is individually packed under optimum compression, ensuring consistent experimental results
  • Efficiency — small column design enables using precious feed sample more efficiently while performing real chromatographic separations in parallel to determine critical quality parameters

The Foresite™ Instruction Manual describes how to use Foresight RoboColumn units prepacked with Bio-Rad chromatography media.

Other formats available:

Learn more about Foresight™ Prepacked Collumn and Plate formats and applications.


Chromatography Resins Available in Foresight Prepacked Columns and Plates
Chromatography Resins Mode
UNOsphere™ Q Strong anion
UNOsphere S Strong cation
UNOsphere Rapid S Strong cation
Nuvia™ Q Strong anion
Nuvia S Strong cation
Nuvia™ cPrime™ Mixed mode
Hydrophobic: cationic
CHT™ Type I — 40 μm particle size Mixed mode
Metal affinity: cationic
CHT Type II — 40 µm particle size Mixed mode
Metal affinity: cationic
  

 

Plate size, mm 128.3 x 86.0 x 14.0
Plate material Polyoxymethylene copolymer
Column inner diameter, mm 5
Column material Polypropylene
Chemical stability All commonly used aqueous buffers, pH 1–14 for UNOsphere™ and Nuvia™ media and pH >6.5 for CHT™ media; organic solvents
Storage solution For UNOsphere Q, UNOsphere S, UNOsphere Rapid S, Nuvia™ cPrime™ media: 20% ethanol
Storage solution For CHT Type I or Type II media — 40 µm particle size: 20% ethanol + 0.01 M NaH2PO4, pH 6.8
Storage solution For Nuvia Q media: 20% ethanol + 1 M NaCl
Storage solution For Nuvia S media: 20% ethanol + 0.1 M NaCl
Storage temperature, °C Recommended: 4–30
Working temperature, °C 4–30
Maximum working pressure, bar Up to 8.0
Flow velocity, cm/h 16–1,000
Laser label Placed on every individual column body; label includes product number, media name, column volume in µl
x

Account price failed to display. Please try reloading the page. Reload Page

If you are placing an order, you may proceed with your order; the account price will be applied if it is lower than the
list price. If the problem persists, please call customer service at   or send an
email to 

Foresight™ MPC™ Type I RoboColumn Unit, 40 µm, 200 µl
Foresight™ MPC™ Type I RoboColumn Unit, 40 µm, 200 µl

7324828
1 row of 8 columns, 200 µl, RoboColumn unit prepacked with MPC Type I mixed-mode chromatography resin, 40 µm particle size

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ MPC™ Type I RoboColumn Unit, 40 µm, 600 µl
Foresight™ MPC™ Type I RoboColumn Unit, 40 µm, 600 µl

7324829
1 row of 8 columns, 600 µl, RoboColumn unit prepacked with MPC Type I mixed-mode chromatography resin, 40 µm particle size

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ Nuvia™ HR-S RoboColumn Unit, 200 µl
Foresight™ Nuvia™ HR-S RoboColumn Unit, 200 µl

7324831
1 row of 8 columns, 200 µl, RoboColumn unit prepacked with Nuvia HR-S strong cation exchange chromatography resin

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ Nuvia™ HR-S RoboColumn Unit, 600 µl
Foresight™ Nuvia™ HR-S RoboColumn Unit, 600 µl

7324832
1 row of 8 columns, 600 µl, RoboColumn unit prepacked with Nuvia HR-S strong cation exchange chromatography resin

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ UNOsphere SUPrA™ RoboColumn Unit, 200 µl
Foresight™ UNOsphere SUPrA™ RoboColumn Unit, 200 µl

7324834
1 row of 8 columns, 200 µl, RoboColumn unit prepacked with UNOsphere SUPrA affinity chromatography resin

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ UNOsphere SUPrA™ RoboColumn Unit, 600 µl
Foresight™ UNOsphere SUPrA™ RoboColumn Unit, 600 µl

7324835
1 row of 8 columns, 600 µl, RoboColumn unit prepacked with UNOsphere SUPrA affinity chromatography resin

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ UNOsphere™ Q RoboColumn Unit

7324819
1 row of 8 columns, 200 μl, RoboColumn unit prepacked with UNOsphere Q strong anion exchange chromatography media

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ UNOsphere™ Q RoboColumn Unit

7324820
1 row of 8 columns, 600 μl, RoboColumn unit prepacked with UNOsphere Q strong anion exchange chromatography media

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ UNOsphere™ S RoboColumn Unit

7324813
1 row of 8 columns, 200 μl, RoboColumn unit prepacked with UNOsphere S strong cation exchange chromatography media

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ UNOsphere™ S RoboColumn Unit

7324814
1 row of 8 columns, 600 μl, RoboColumn unit prepacked with UNOsphere S strong cation exchange chromatography media

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ UNOsphere™ Rapid S RoboColumn Unit

7324816
Foresight UNOsphere Rapid S RoboColumn Units are no longer available. Please use Foresight UNOsphere S or Foresight™ Nuvia™ HR-S RoboColumn Units as alternative products.

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ UNOsphere™ Rapid S RoboColumn Unit

7324817
Foresight UNOsphere Rapid S RoboColumn Units are no longer available. Please use Foresight UNOsphere S or Foresight™ Nuvia™ HR-S RoboColumn Units as alternative products.

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ Nuvia™ Q RoboColumn Unit

7324804
1 row of 8 columns, 200 μl, RoboColumn unit prepacked with Nuvia Q strong anion exchange chromatography media

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ Nuvia™ Q RoboColumn Unit

7324805
1 row of 8 columns, 600 μl, RoboColumn unit prepacked with Nuvia Q strong anion exchange chromatography media

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ Nuvia™ S RoboColumn Unit

7324801
1 row of 8 columns, 200 μl, RoboColumn unit prepacked with Nuvia S strong cation exchange chromatography media

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ Nuvia™ S RoboColumn Unit

7324802
1 row of 8 columns, 600 μl, RoboColumn unit prepacked with Nuvia S strong cation exchange chromatography media

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ Nuvia™ cPrime™ RoboColumn Unit

7324807
1 row of 8 columns, 200 μl, RoboColumn unit prepacked with Nuvia cPrime hydrophobic cation exchange chromatography media

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ Nuvia™ cPrime™ RoboColumn Unit

7324808
1 row of 8 columns, 600 μl, RoboColumn unit prepacked with Nuvia cPrime hydrophobic cation exchange chromatography media

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
(Discontinued) Foresight™ CHT™ Type I RoboColumn Unit

7324822
1 row of 8 columns, 200 μl, RoboColumn unit prepacked with CHT ceramic hydroxyapatite Type I multimodal chromatography media, 40 μm particle size

This product is no longer available. Please contact technical support for more information on replacement product.
Foresight™ CHT™ Type I RoboColumn Unit

7324823
1 row of 8 columns, 600 μl, RoboColumn unit prepacked with CHT ceramic hydroxyapatite Type I multimodal chromatography media, 40 μm particle size

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
Foresight™ CHT™ Type II RoboColumn Unit

7324825
1 row of 8 columns, 200 μl, RoboColumn unit prepacked with CHT ceramic hydroxyapatite Type II multimodal chromatography media, 40 μm particle size

List Price:
 
Inquire
Loading
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Quote
Add to Hot List  
(Discontinued) Foresight™ CHT™ Type II RoboColumn Unit

7324826
1 row of 8 columns, 600 μl, RoboColumn unit prepacked with CHT ceramic hydroxyapatite Type II multimodal chromatography media, 40 μm particle size

This product is no longer available. Please contact technical support for more information on replacement product.
Number Description Options
6297 Foresight™ Prepacked Plates and Columns Product Information Sheet, Rev B Click to download [ Add to Cart (Free) ]
10027565 Instruction Manual, Foresight™ RoboColumn Units 200 and 600 µl, Rev A Click to download
10024831 Instruction Manual, Foresight™ Chromatography Media Columns 1 and 5 ml, Rev A Click to download
10024413 Instruction Manual, Foresight™ Chromatography Media Filter Plates, Rev A Click to download