Experion RNA Analysis Kits

Description

Description

Experion™ RNA analysis kits combine innovative chip design with high-quality reagents to perform reproducible, quantitative, and accurate RNA analyses in minutes. Streamlined chip preparation methods and low sample and reagent volume requirements result in rapid experiments with minimal hands-on time.

The Experion RNA StdSens and RNA HighSens analysis kits provide accurate assessment of RNA quality prior to downstream experiments. The kits offer rapid single-step purity assessments and the ability to analyze 1 to 12 samples in approximately 30 min. Sample concentrations in nanogram (RNA StdSens analysis kit) or picogram (RNA HighSens analysis kit) amounts can be analyzed. Refer to the specifications tab for more details.

The Experion automated electrophoresis system can also be used for a number of upstream and downstream workflows in other nucleic acid and protein applications.

Specifications

Specifications

RNA HighSens Assay
 
Number of samples
1–11
Sample volume
1 µl
Quantitation range
100–5,000 pg/µl
Separation range
100–6,000 bases
Sensitivity
100 pg
RNA StdSens Assay
 
Number of samples
1–12
Sample volume
1 µl
Quantitation range
5–500 ng/µl
Sensitivity
5 ng

Ordering

Ordering

items

Use the filters below to refine results!

Image
700-7103_tn.jpg
7007103
Standard-sensitivity RNA analysis kit, includes 10 RNA StdSens chips, 2 cleaning chips, reagents (RNA gel and ladder, RNA StdSens stain and loading buffer), 2 spin filters
Image
700-7104_tn.jpg
7007104
Standard-sensitivity RNA analysis kit, includes 25 RNA StdSens chips, 2 cleaning chips, reagents (RNA gel and ladder, RNA StdSens stain and loading buffer), 4 spin filters
Image
700-7105_tn.jpg
7007105
High-sensitivity RNA analysis kit, includes 10 RNA HighSens chips, 2 cleaning chips, reagents (RNA gel and ladder, RNA HighSens stain and loading buffer, RNA sensitivity enhancer), 2 spin filters
Image
700-7106_tn.jpg
7007106
High-sensitivity RNA analysis kit, includes 25 RNA HighSens chips, 2 cleaning chips, reagents (RNA gel and ladder, RNA HighSens stain and loading buffer, RNA sensitivity enhancer), 4 spin filters
Image
700-7153_tn.jpg
7007153
Pkg of 10, microfluidic chips for standard-sensitivity RNA analysis with the Experion automated electrophoresis system, comes with 2 cleaning chips
Image
700-7154_tn.jpg
7007154
Reagents for use with 10 Experion RNA StdSens chips, includes RNA gel and ladder, RNA StdSens stain and loading buffer, 2 spin filters
Image
700-7155_tn.jpg
7007155
Pkg of 10, microfluidic chips for high-sensitivity RNA analysis with the Experion automated electrophoresis system, comes with 2 cleaning chips
Image
700-7156_tn.jpg
7007156
Reagents and supplies for use with 10 Experion RNA HighSens chips, includes RNA gel and ladder, RNA HighSens stain and loading buffer, RNA sensitivity enhancer, 2 spin filters
Image
700-7251_tn.jpg
7007251
Pkg of 10, cleaning chip for use with the Experion electrophoresis station (#700-7010)
Image
700-7252_tn.jpg
7007252
250 ml, for use with Experion cleaning chips (#700-7251)
Image
700-7253_tn.jpg
7007253
100 ml, DEPC-treated water for use with the Experion automated electrophoresis system
Image
700-7254_tn.jpg
7007254
Pkg of 10, spin filter, for use with Experion analysis kits
Image
700-7255_tn.jpg
(Discontinued) RNA Ladder
7007255
20 μl, RNA size standards, replacement component of Experion RNA analysis kits
Image
700-7264_tn.jpg
(Discontinued) Cleaning Swabs
7007264
Pkg of 25, swab for use with any Experion analysis kit

Documents

Documents

Number Description Options
3140
Experion Automated Electrophoresis System Brochure, Rev F
3170
Experion RNA HighSens and RNA StdSens Analysis Kits, PIS, Rev E
3171
Experion Software PIS, Rev C
3186
Experion Automated Electrophoresis System Flier, Rev A
5253
Experion System Performance Comparison, Rev A
5286
Performance Comparison of the Experion Automated Electrophoresis System and a Competing Automated System for RNA Analysis, Rev A
5315
Using the Experion Automated Electrophoresis System to Assess RNA Quality and Quantity in siRNA-Induced Gene Silencing Experiments, Rev A
5420
Experion RNA Quantitation Methods, Rev A
5452
Effect of RNA Degradation on Data Quality in Quantitative PCR and Microarray Experiments, Rev B
6959
Biomarker Workflow Solutions Brochure, Rev A
5732
Experion Pro260 and RNA StdSens Starter Kits PIS, Rev B
5761
Development and Validation of RQI: An RNA Quality Indicator for the Experion Automated Electrophoresis System, Rev B
5783
Experion Automated Electrophoresis System Flier, Rev A
5868
Performance Comparison of Two LabChip Microfluidic Platforms for Protein, DNA, and RNA Analyses, Rev A
5893
Myth Busted: A NanoDrop ND-1000 Spectrophotometric Reading Is Insufficient to Assess RNA Quality, Rev A
10000976
Instruction Manual, Experion RNA StdSens and HighSens Analysis Kits, Rev C
10001312
Instruction Manual, Experion Automated Electrophoresis System, Rev C
10004491
Quick Guide, Experion RNA HighSens Analysis Kit, Rev B
10004492
Quick Guide, Experion RNA StdSens Analysis Kit, Rev B
10005250
Instruction Manual, IQ/OQ Protocols and Instuctions, Experion Electrophoresis Station, Rev D
10005581
Instruction Manual, Experion Security Edition Software Setup Guide, Rev C
10005740
Quick Installation Guide, Experion System Software Windows XP, Rev A
10014627
Quick Installation Guide, Experion System Software Windows VISTA, Rev A