RQI (RNA Quality Indicator) Number

RQI (RNA quality indicator) is a number (on a scale of 1–10) that is automatically generated for mammalian eukaryotic total RNA samples. An RQI of 1 is highly degraded, while an RQI of 10 is highly intact total RNA. RQI enables users to easily judge the integrity of their total RNA sample in addition to the visual aid of the electropherogram and reported ribosomal peak area ratio.

RQI setting in the Experion software interface. Top panel, screen capture of Run Summary page that displays the RQI value for each RNA sample along with a color-codes RQI classification. When the RNA concentration is too low to accurately determine an RQI value, a message is displayed in the RQI Alert column of the summary page. RNA migration profiles and a virtual image of the gel are also displayed for easy visual assessment of RNA quality; bottom panel, screen capture of user-editable RQI color coding. The checkbox to override the low RNA concentration alert is indicated by an arrow, The default setting are: , 1 ≤ RQI ≤ 4; , 4 < RQI ≤ 7; , 7 < RQI ≤10. The actual cutoff values for specific applications have to be determined empirically.

Varying Degrees of Degradation by Heat and by Natural RNases

Comparison of electropherogram profiles and RQI values at different time points between natural RNase and heat-mediated degradations. RNA extracted from rat livers incubated at room temperature prior to extraction (left) is compared to profiles from heat-degraded RNA (right). 18S and 28S rRNA peaks map at 40 sec and 47 sec, respectively. RQI value and incubation time is indicated for each graph.

Intact Total RNA

Profiles of total RNA isolated from HPRT siRNA-transfected HeLa cells. Samples were separated with the Experion™ RNA StdSens analysis kit to generate A, an electropherogram and B, a simulated gel view. The 18S and 28S rRNA peaks are indicated. The peak at the far left of the electropherogram corresponds to the lower marker (indicated by arrow) used for alignment of the sample wells.

Pipet Tips Recommended for Experion Chip Loading

(Narrow-bore tips such as A and B are recommended. Tips C,D,E not recommended.)


Filter tips are always recommended for RNA work.

Examples of recommended pipet tips for loading chips:

For RNA or DNA work:

  • Rainin L-10F
  • Rainin SR-L10F
  • Rainin GP-L10F
  • VWR 87001-688

For protein work:

  • Rainin GP-L10F
  • Rainin GP-10G
  • Rainin GP-10F
  • Rainin GP-10S
  • Rainin GP-10
  • VWR 87001-688

 

RNA StdSens Ladder Electropherogram


Electropherogram of the Experion RNA Ladder for the mRNA assays illustrating the relative positions of the lower marker (LM, the first peak) and RNA ladder peaks (eight peaks from 200–6,000 nt).

RNA Integrity Webinar

November 25, 2009
Arnaud Remy and Michael W. Pfaffl

This two-part webinar by Arnaud Remy (Bio-Rad) and Michael W. Pfaffl (Technical University of Munich) discusses the technology and principles of RNA analysis by automated electrophoresis and compares the use of two available platforms for the determinations of RNA integrity, an essential step in quantitative PCR experiments. Duration: 48 min.

Click here to view video

Experion™ RNA analysis kits combine innovative chip design with high-quality reagents to perform reproducible, quantitative, and accurate RNA analyses in minutes. Streamlined chip preparation methods and low sample and reagent volume requirements result in rapid experiments with minimal hands-on time.

The Experion RNA StdSens and RNA HighSens analysis kits provide accurate assessment of RNA quality prior to downstream experiments. The kits offer rapid single-step purity assessments and the ability to analyze 1 to 12 samples in approximately 30 min. Sample concentrations in nanogram (RNA StdSens analysis kit) or picogram (RNA HighSens analysis kit) amounts can be analyzed. Refer to the specifications tab for more details.

The Experion automated electrophoresis system can also be used for a number of upstream and downstream workflows in other nucleic acid and protein applications.

RNA HighSens Assay  
Number of samples 1–11
Sample volume 1 µl
Quantitation range 100–5,000 pg/µl
Separation range 100–6,000 bases
Sensitivity 100 pg
RNA StdSens Assay  
Number of samples 1–12
Sample volume 1 µl
Quantitation range 5–500 ng/µl
Sensitivity 5 ng
Experion RNA StdSens Analysis Kit for 10 Chips

700-7103
Standard-sensitivity RNA analysis kit, includes 10 RNA StdSens chips, 2 cleaning chips, reagents (RNA gel and ladder, RNA StdSens stain and loading buffer), 2 spin filters

List Price:   $458.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
Experion RNA StdSens Analysis Kit for 25 Chips

700-7104
Standard-sensitivity RNA analysis kit, includes 25 RNA StdSens chips, 2 cleaning chips, reagents (RNA gel and ladder, RNA StdSens stain and loading buffer), 4 spin filters

List Price:   $874.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
Experion RNA HighSens Analysis Kit for 10 Chips

700-7105
High-sensitivity RNA analysis kit, includes 10 RNA HighSens chips, 2 cleaning chips, reagents (RNA gel and ladder, RNA HighSens stain and loading buffer, RNA sensitivity enhancer), 2 spin filters

List Price:   $473.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
Experion RNA HighSens Analysis Kit for 25 Chipss

700-7106
High-sensitivity RNA analysis kit, includes 25 RNA HighSens chips, 2 cleaning chips, reagents (RNA gel and ladder, RNA HighSens stain and loading buffer, RNA sensitivity enhancer), 4 spin filters

List Price:   $922.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
Experion RNA StdSens Chips

700-7153
Pkg of 10, microfluidic chips for standard-sensitivity RNA analysis with the Experion automated electrophoresis system, comes with 2 cleaning chips

List Price:   $387.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
Experion RNA StdSens Reagents and Supplies

700-7154
Reagents for use with 10 Experion RNA StdSens chips, includes RNA gel and ladder, RNA StdSens stain and loading buffer, 2 spin filters

List Price:   $281.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
Experion RNA HighSens Chips

700-7155
Pkg of 10, microfluidic chips for high-sensitivity RNA analysis with the Experion automated electrophoresis system, comes with 2 cleaning chips

List Price:   $387.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
Experion RNA HighSens Reagents and Supplies

700-7156
Reagents and supplies for use with 10 Experion RNA HighSens chips, includes RNA gel and ladder, RNA HighSens stain and loading buffer, RNA sensitivity enhancer, 2 spin filters

List Price:   $301.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
Experion Cleaning Chips

700-7251
Pkg of 10, cleaning chip for use with the Experion electrophoresis station (#700-7010)

List Price:   $157.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
Experion Electrode Cleaner

700-7252
250 ml, for use with Experion cleaning chips (#700-7251)

List Price:   $60.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
Experion DEPC-Treated Water

700-7253
100 ml, DEPC-treated water for use with the Experion automated electrophoresis system

List Price:   $106.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
Experion Spin Filters

700-7254
Pkg of 10, spin filter, for use with Experion analysis kits

List Price:   $74.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
RNA Ladder

700-7255
20 μl, RNA size standards, replacement component of Experion RNA analysis kits

List Price:   $60.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
Cleaning Swabs

700-7264
Pkg of 25, swab for use with any Experion analysis kit

List Price:   $49.00
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
Number Description Options
BR124 BioRadiations Magazine, Number 124 Click to download [ Add to Cart (Free) ]
BR126 BioRadiations Magazine, Number 126 Click to download [ Add to Cart (Free) ]
3140 Experion Automated Electrophoresis System Brochure, Rev F Click to download [ Add to Cart (Free) ]
3170 Experion RNA HighSens and RNA StdSens Analysis Kits, PIS, Rev E Click to download
3171 Experion Software PIS, Rev C Click to download
3174A Experion Folder (includes bulletins 3140, 3169, 3170, 3171, and 3184) [ Add to Cart (Free) ]
3184 Experion Video Tour CD [ Add to Cart (Free) ]
3186 Experion Automated Electrophoresis System Flier, Rev A Click to download
5253 Experion System Performance Comparison, Rev A Click to download
5285 Bio-Rad Applies Microfluidics to Automate Gel Electrophoresis, Rev C Click to download
5286 Performance Comparison of the Experion Automated Electrophoresis System and a Competing Automated System for RNA Analysis, Rev A Click to download
5315 Using the Experion Automated Electrophoresis System to Assess RNA Quality and Quantity in siRNA-Induced Gene Silencing Experiments, Rev A Click to download
5420 Experion RNA Quantitation Methods, Rev A Click to download
5452 Effect of RNA Degradation on Data Quality in Quantitative PCR and Microarray Experiments, Rev B Click to download
5460 Biomarker Discovery Workflow Brochure, Rev B Click to download
5732 Experion Pro260 and RNA StdSens Starter Kits PIS, Rev B Click to download
5761 Development and Validation of RQI: An RNA Quality Indicator for the Experion Automated Electrophoresis System, Rev B Click to download
5783 Experion Automated Electrophoresis System Flier, Rev A Click to download
5859 A Practical Approach to RT-qPCR — Publishing Data That Conform to the MIQE Guidelines, Rev D Click to download [ Add to Cart (Free) ]
5868 Performance Comparison of Two LabChip Microfluidic Platforms for Protein, DNA, and RNA Analyses, Rev A Click to download
5893 Myth Busted: A NanoDrop ND-1000 Spectrophotometric Reading Is Insufficient to Assess RNA Quality, Rev A Click to download
10000976 Instruction Manual, Experion RNA StdSens and HighSens Analysis Kits, Rev C Click to download
10001312 Instruction Manual, Experion Automated Electrophoresis System, Rev C Click to download
10004491 Quick Guide, Experion RNA HighSens Analysis Kit, Rev B Click to download
10004492 Quick Guide, Experion RNA StdSens Analysis Kit, Rev B Click to download
10005250 Instruction Manual, IQ/OQ Protocols and Instuctions, Experion Electrophoresis Station, Rev D Click to download
10005581 Instruction Manual, Experion Security Edition Software Setup Guide, Rev C Click to download
10005740 Quick Installation Guide, Experion System Software Windows XP, Rev A Click to download
10014627 Quick Installation Guide, Experion System Software Windows VISTA, Rev A Click to download
RP0045 Standardization of qPCR and RT-qPCR Click to download