BioLogic DuoFlow 40 System

The BioLogic DuoFlow 40 system includes an F40 workstation for a flow rate of up to 40 ml/min* at 1,000 psi (66 bar, 6.6 MPa). A Model MX-1 mixer, 3-tray rack, AVR7-3 sample inject valve, fittings kit, UV detector with 5 mm flow cell and 254/280 nm filters, conductivity monitor, starter kit, UNO Q1 column, and instructions are also included.

* To double the flow rate to up to 80 ml/min, use the BioLogic Maximizer valve system. The optional F10 pump kit enables a flow rate of 0.01–10 ml/min at 3,500 psi (233 bar, 23 MPa).

BioLogic QuadTec 40 System

The BioLogic DuoFlow QuadTec 40 system includes:

  • F40 workstation for a flow rate of 40 ml/min* at 1,000 psi (66 bar, 6.6 MPa)
  • BioLogic QuadTec UV/Vis detector for simultaneous monitoring of four wavelengths ranging from 190–740 nm (with deuterium lamp at 190–&n370 nm and optional halogen lamp at 370–740 nm)
A Model MX-1 mixer, 3-tray rack, AVR7-3 sample inject valve, fittings kit, instrument control module (ICM), system cables 25 and 26, conductivity monitor, starter kit, UNO Q1 column, and instructions are also included.

 

* Flow rates can be doubled with the addition of the BioLogic Maximizer valve system.

BioLogic Maximizer 80 System

The BioLogic DuoFlow Maximizer 80 system includes:

  • F40 workstation
  • BioLogic Maximizer valve system for flow rates of up to 80 ml/min
  • BioLogic DuoFlow pH monitor for real-time monitoring of pH conditions during a run
  • BioFrac fraction collector for the widest range of collection capabilities
A BioLogic Maximizer mixer, Model MX-1 mixer, 3-tray rack, AVR7-3 sample inject valve, fittings kit, UV detector with 5 mm flow cell and 254/280 nm filters, conductivity monitor, starter kit, UNO Q1 column, diverter valve, two F1 racks, and instructions are also included.

 

BioLogic Pathfinder 80 System

The BioLogic DuoFlow Pathfinder 80 system includes:

  • F40 workstation
  • BioLogic Maximizer valve system for flow rates of up to 80 ml/min
  • BioLogic QuadTec UV/Vis detector for simultaneous monitoring of four wavelengths ranging from 190–740 nm (with deuterium lamp at 190–370 nm and optional halogen lamp at 370–740 nm)
  • BioLogic DuoFlow pH monitor for real-time monitoring of pH conditions during a run
  • BioFrac fraction collector for the widest range of collection capabilities
A BioLogic Maximizer mixer, MX-1 mixer, 3-tray rack, AVR7-3 sample inject valve, fittings kit, system cable 25, conductivity monitor, starter kit, UNO Q1 column, diverter valve, two F1 racks, and instructions are also included.

 

The BioLogic DuoFlow 40 workstation includes an F40 pump for a flow rate of up to 40 ml/min* at 1,000 psi (66 bar, 6.6 MPa).

The BioLogic DuoFlow 40 workstation is a component of the following systems:

  • BioLogic DuoFlow 40 system
  • BioLogic DuoFlow QuadTec 40 system
  • BioLogic DuoFlow Maximizer 80 system
  • BioLogic DuoFlow Pathfinder 80 system

* To double the flow rate to up to 80 ml/min, use the BioLogic Maximizer valve system. The optional F10 pump kit enables a flow rate of 0.01–10 ml/min at 3,5000 psi (233 bar, 23 MPa).

Technical Specifications BioLogic DuoFlow Systems
Flow rate limit 10 ml/min 20 ml/min; optional Maximizer valve system
Pressure limit 3,500 psi (23 MPa) at 10 ml/min
UV detection Standard 254 and 280 nm filters; optional 214, 365, 405, 436, and 546 nm filters; standard 5 mm analytical flow cell; optional 2 mm preparative flow cell; optional BioLogic QuadTec UV/Vis detector, 4-wavelength simultaneous detection
Conductivity Standard
pH detection Optional
Other detectors Optional signal import module (SIM), adds pH, refractive index, and fluorescence detectors
Buffer selection/large sample loading Optional SV5-4 buffer-select valve, Model EP-1 Econo pump or Econo gradient pump
Sample injection AVR7-3 valve
Multiple sample injection Optional DynaLoop sample loops; 25 ml, 90 ml
General fraction collection BioFrac or Model 2110 fraction collector
Large-volume fraction collection BioFrac fraction collector with optional prep adaptor or AVR9-8 valve
Small-volume fraction collection BioFrac or Model 2110 fraction collector
Buffer blending Optional Maximizer valve system
Column scouting/column switching Optional AVR9-8 valves for =8 columns or additional AVR7-3 valve for 2 columns
Reverse-flow chromatography Additional AVR7-3 valve
Solvent compatibility All commonly used chromatographic solvents
Operating temperature 4–40°C
Dimensions (W x D x H) 35 x 41 x 81 cm (13.8 x 16 x 31.8")
Weight 70 kg (154 lb)
BioLogic DuoFlow F40 Workstation

760-0140
Pkg of 1, medium-pressure chromatography workstation, includes mixer barrel extenders, for use with the F40 pump

List Price:   Log in
Your Price:   Log in
Quantity:   Add to cart
Add to Hot List   Add to Quote
Number Description Options
4106040 Instruction Manual, V9-8 Manual, and AV9-8 Automated Stream Select Valves, Rev C Click to download
5369 Biologic DuoFlow System Family Brochure, Rev A Click to download [ Add to Cart (Free) ]
2815 BioLogic DuoFlow Valve Brochure, Rev C Click to download
2584 BioLogic DuoFlow Valving Guide, Rev E Click to download
2744 BioLogic DuoFlow System Selection Guide, Rev C Click to download
2687 BioLogic DuoFlow Chromatography System Brochure, Rev D Click to download [ Add to Cart (Free) ]
4006210 Instruction Manual, BioLogic™ Chromatography System Click to download
4006229 Instruction Manual, BioLogic DuoFlow™ Chromatography System, Rev B Click to download