Bio-Plex System Validation and Calibration Tools

Bio-Plex System Validation and Calibration Tools

System performance validation and calibration tools for the Bio-Plex 200 system ensure reliability and consistency of assay results. Both validation and calibration protocols are automated.

Read More
Ordering Information

Overview

System performance validation and calibration tools for the Bio-Plex 200 system ensure reliability and consistency of assay results. Both validation and calibration protocols are automated by Bio-Plex Manager software, and records are stored in a secure Bio-Plex database file. Procedures are performed using a maintenance, calibration, and validation (MCV) plate that holds the required bead sets and solutions.

Bio-Plex validation and calibration kits, Bio-Plex Manager software, and the Bio-Plex MCV plate IV enable you to:

  • Perform routine instrument maintenance, calibration, and validation procedures
  • Assess and document the performance of all system components
  • Discriminate between instrument and assay problems

Bio-Plex Validation Kit 4.0 and Bio-Plex MCV Plate IV
The Bio-Plex validation kit 4.0 includes bead sets for validation routines (optics, reporter, classify, and fluidics validation) using Bio-Plex Manager software and the Bio-Plex MCV plate IV.

Key features include:

  • Automated validation with both high and low PMT settings
  • Broadened classification regions from region 1 to 100
  • Bio-Plex flashlight for visual inspection and adjustment of sample-needle height
  • Two needle-height adjustment options to accommodate various plate types
  • Bio-Plex reservoir to enable unattended operation of maintenance functions

Bio-Plex Calibration Kit
The Bio-Plex calibration kit consists of a set of gold standard calibration beads with stable fluorescent signals. Calibration standardizes signal output from day to day and from instrument to instrument. The Bio-Plex system allows calibration at two different settings. The calibration for broad range standards provides the widest available dynamic range, while the calibration for low range standards with Bio-Plex Manager software StatLIA curve fitting provides the greatest sensitivity.

Ordering

items

Use the filters below to refine results!

Image
171-203001_tn.jpg
171203001
Performance testing tool for Bio-Plex 200 system; works with Bio-Plex Manager 4.0, 4.1.1, 5.0, or 6.0 software and (uses MCV plate IV); ~50 validation routines
Image
171-203060_tn.jpg
171203060
Performance testing tool for Bio-Plex 200 system, includes Cal1 and Cal2 calibration beads; ~50 daily calibration routines

Accessories

Image
171-203033_tn.jpg
171203033
Pkg of 1, maintenance, calibration, and validation plate for performance testing of Bio-Plex 200 system; works with Bio-Plex Manager 4.0, 4.1.1, 5.0, or 6.0 software and validation kit 4.0

Documents

Number Description Options
5405
Bio-Plex® Multiplex System Brochure, Ver E
[ Add to Cart (Free) ]
3076
Bio-Plex Care and Maintenance Quick Guide, Rev B
2993
Bio-Plex Glossary, Rev A
4100205
Bio-Plex Maintenance Log, Rev A
3000
Correlation of Bio-Plex Suspension Array Reader Validation With Multiplex Cytokine Assay Performance, Rev A
4110016
Instruction Manual, Bio-Plex Calibration Kit Product Insert, Rev B
4110007
Instruction Manual, Bio-Plex Validation Kit 3.0, Rev C
4110017
Instruction Manual, Bio-Plex Validation Kit 3.0 Specification Sheet, Rev B
4110185
Instruction Manual, Bio-Plex Validation Kit 4.0, Rev B
2879
Bio-Plex System Tools Brochure, Rev C