Bio-Plex Pro™ RBM Human Kidney Toxicity Assays

Print
Bio-Plex Pro™ RBM Human Kidney Toxicity Assays

Overview

Available Bio-Plex Pro™ RBM Human Kidney Toxicity Assays
Human Kidney Toxicity Panel 1
(171ATR1CK)
Analyte Bead Region
Calbindin 64
Clusterin  12
GST-π 25
IL-18 21
KIM-1 44
MCP-1 15
Human Kidney Toxicity Panel 2
(171ATR2CK)
Analyte Bead Region
Albumin 30
B2M 22
Cystatin C 51
NGAL 46
Osteopontin 20
TFF3 61

Use the Bio-Plex® Assay Builder to design your customized Bio-Plex Assay in four easy steps

With Assay Builder you can also:

  • Get a price quote
  • Place your order online
  • Look up an existing assay by catalog number

To design your customized Express or x-Plex assay, process your catalog number, and obtain pricing information, launch the Assay Builder

To create a Bio-Plex custom assay, click Launch Bio-Plex Assay Builder.

Launch Bio-Plex Assay Builder

Bio-Plex® Technology and Applications
Scroll upScroll down


The Bio-Plex Pro RBM kidney toxicity assays, developed in partnership with Myriad RBM, comprise a highly relevant set of biomarkers for early detection and characterization of kidney toxicity/injury. Myriad RBM’s close collaboration with the Predictive Safety Testing Consortium (PSTC), FDA, and European Medicines Evaluation Agency (EMEA) was instrumental in the selection of markers found in these panels.

The assays are built on magnetic beads to enable robust quantification of multiple proteins in human urine samples, providing valuable information throughout drug development — from lead optimization to preclinical and clinical protocol decision making. Assays are offered as premixed all-in-one kits for research involving:

  • Drug-induced kidney toxicity
  • Diabetes
  • High blood pressure
  • Glomerulonephritis
  • Polycystic kidney disease
  • Chronic infection
  • SLE (lupus) and other autoimmune disorders

Bio-Plex Pro RBM human kidney toxicity assays are available as two panels:

    Panel 1
  • Calbindin
  • Clusterin
  • GST-π
  • IL-18
  • KIM-1
  • MCP-1
    Panel 2
  • Albumin
  • B2M
  • Cystatin C
  • NGAL
  • Osteopontin
  • TFF3

Based on 6.5 µm magnetic beads, these assay panels are compatible with both vacuum and magnetic wash stations. Magnetic washing simplifies plate processing, provides increased throughput, and results in decreased variability and increased reproducibility.

Key Features

  • Optimized for high precision and lot-to-lot reproducibility of sample measurements
  • Magnetic beads for simplified plate processing
  • 2-level quality controls with lot-specific ranges
  • Assay quick guide to get you started right away
  • High-quality design ensures robust and reproducible measurement of nephrotoxicity biomarkers in human, rat, and canine urine samples

Ordering Options

Premixed all-in-one kits

Instrument Compatibility

More Information

See how Bio-Plex instruments and assays benefit researchers studying heart disease, leukemia, melanoma, and other cancers.

x

Account price failed to display. Please try reloading the page.Reload Page

If you are placing an order, you may proceed with your order; the account price will be applied if it is lower than the
list price. If the problem persists, please call customer service at or send an
email to

Bio-Plex Pro™ RBM Human Kidney Toxicity Panel 1

171ATR1CK
1 x 96-well, includes magnetic capture beads, detection antibodies, standards, controls, diluent, buffers, streptavidin-PE, flat bottom plate, and plate seals, for the detection of 6 kidney toxicity markers in human urine

171ATR1CK /templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Pro-RBM-Kidney-Toxicity-Assays/171-ATR1CK_1359401551.xml 171ATR1CK 01/28/13 10:55 AM N en 01/30/23 11:30 AM true true internet/product_SKU AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA LSR 2018-02-01 00:14:20 171atr1ck-bio-plex-pro-rbm-human-kidney-toxicity-panel-1 171ATR1CK Bio-Plex Pro? RBM Human Kidney Toxicity Panel 1 Bio-Plex Pro&#153; RBM Human Kidney Toxicity Panel 1 1 x 96-well, includes magnetic capture beads, detection antibodies, standards, controls, diluent, buffers, streptavidin-PE, flat bottom plate, and plate seals, for the detection of 6 kidney toxicity markers in human urine 1 x 96-well, includes magnetic capture beads, detection antibodies, standards, controls, diluent, buffers, streptavidin-PE, flat bottom plate, and plate seals, for the detection of 6 kidney toxicity markers in human urine /webroot/web/images/lsr/products/bioplex_suspension_array/sku_thumb/global/en-us/category/bio-plex-multiplex-immunoassay-system?ID=85824182-db2a-4c6e-ac82-4e07dd9ab904-pro-rbm-human-toxicity-panel-1-171-atr1ck-tn.jpg /webroot/web/images/lsr/products/bioplex_suspension_array/sku_view/global/en-us/category/bio-plex-multiplex-immunoassay-system?ID=85824182-db2a-4c6e-ac82-4e07dd9ab904-pro-rbm-human-toxicity-panel-1-171-atr1ck-view.jpg Karen Moss Bio-Plex Pro&#153; RBM Human Kidney Toxicity Panel 1 1 x 96-well, includes magnetic capture beads, detection antibodies, standards, controls, diluent, buffers, streptavidin-PE, flat bottom plate, and plate seals, for the detection of 6 human kidney toxicity markers in urine 171ATR1CK, bio-plex, pro, rbm, human, kidney, toxicity, panel, 6-plex, plex, bioplex, premade, pre-made, multiplex, bead-based, assays, immunoassay, coupled, magnetic, beads, detection, antibodies 01/28/13 10:55 AM 01/30/23 11:30 AM AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA en LSR /LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Pro-RBM-Kidney-Toxicity-Assays N 0 <p>The <a href="/evportal/destination/commerce/product_detail?catID=MH3RQ8E8Z">Bio-Plex Pro human kidney toxicity</a> panel 1 immunoassay is an all-in-one 1 x 96-well kit that includes premixed magnetic capture beads and detection antibodies, standards, 2-level controls, standard diluent, buffers (blocking, sample dilution, and 10x assay), 10x streptavidin-PE, flat bottom plate/seals, and instructions for the detection of the following analytes:</p> <ul> <li>Calbindin</li> <li>Clusterin</li> <li>GST-&pi;</li> <li>IL-18</li> <li>KIM-1</li> <li>MCP-1</li> </ul> <p>Instrument Compatibility</p> <ul> <li><a href="/evportal/destination/commerce/product_detail?catID=M3VE8D15">Bio-Plex<sup>&reg;</sup> MAGPIX&trade; multiplex reader</a></li> <li><a href="/evportal/destination/commerce/product_detail?catID=715b85f1-6a4e-41b3-b5d9-80202d779e13">Bio-Plex<sup>&reg;</sup> 200 system</a></li> <li><a href="/evportal/destination/commerce/product_detail?catID=L1AW4B15">Bio-Plex 3D suspension array system</a></li> <li><a href="/evportal/destination/commerce/product_detail?catID=2d1708e6-6b73-4329-833a-07881e7dd82c">Bio-Plex Pro wash stations</a></li> </ul> /webroot/web/html/lsr/products/bioplex_suspension_array/sku_view/description/global bio-plex-pro-rbm-human-kidney-toxicity-panel-1-171-atr1ck-desc.html /webroot/web/html/lsr/products/bioplex_suspension_array/sku_view/description/global/en-us/category/bio-plex-multiplex-immunoassay-system?ID=85824182-db2a-4c6e-ac82-4e07dd9ab904-pro-rbm-human-kidney-toxicity-panel-1-171-atr1ck-desc.html 1 0 false false false /prd/en/CA/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=171ATR1CK&CartQuote=QT&quantity= false true false $2,105.00 false null /prd/en/CA/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=171ATR1CK&AddToDefaultWishList=true&quantity= true false true true false true true true /prd/en/CA/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=171ATR1CK&quantity= 171ATR1CK
List Price: 
 
$2,105.00 
LoadingLoading...
EDU Price:
  What is this?
Your Price: 
 
LoadingLoading...
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Cart
 
 
Bio-Plex Pro™ RBM Human Kidney Toxicity Panel 2

171ATR2CK
1 x 96-well, includes magnetic capture beads, detection antibodies, standards, controls, diluent, buffers, streptavidin-PE, flat bottom plate, and plate seals, for the detection of 6 kidney toxicity markers in human urine

171ATR2CK /templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Pro-RBM-Kidney-Toxicity-Assays/171-ATR2CK_1359402106.xml 171ATR2CK 01/28/13 11:32 AM N en 01/30/23 11:40 AM true true internet/product_SKU AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA LSR 2018-02-01 00:14:20 171atr2ck-bio-plex-pro-rbm-human-kidney-toxicity-panel-2 171ATR2CK Bio-Plex Pro? RBM Human Kidney Toxicity Panel 2 Bio-Plex Pro&#153; RBM Human Kidney Toxicity Panel 2 1 x 96-well, includes magnetic capture beads, detection antibodies, standards, controls, diluent, buffers, streptavidin-PE, flat bottom plate, and plate seals, for the detection of 6 kidney toxicity markers in human urine 1 x 96-well, includes magnetic capture beads, detection antibodies, standards, controls, diluent, buffers, streptavidin-PE, flat bottom plate, and plate seals, for the detection of 6 kidney toxicity markers in human urine /webroot/web/images/lsr/products/bioplex_suspension_array/sku_thumb/global/en-us/category/bio-plex-multiplex-immunoassay-system?ID=85824182-db2a-4c6e-ac82-4e07dd9ab904-pro-rbm-human-toxicity-panel-2-171-atr2ck-tn.jpg /webroot/web/images/lsr/products/bioplex_suspension_array/sku_view/global/en-us/category/bio-plex-multiplex-immunoassay-system?ID=85824182-db2a-4c6e-ac82-4e07dd9ab904-pro-rbm-human-toxicity-panel-2-171-atr2ck-view.jpg Karen Moss Bio-Plex Pro&#153; RBM Human Kidney Toxicity Panel 2 1 x 96-well, includes magnetic capture beads, detection antibodies, standards, controls, diluent, buffers, streptavidin-PE, flat bottom plate, and plate seals, for the detection of 6 human kidney toxicity markers in urine 171ATR2CK, bio-plex, pro, rbm, human, kidney, toxicity, panel, 6-plex, plex, bioplex, premade, pre-made, multiplex, bead-based, assays, immunoassay, coupled, magnetic, beads, detection, antibodies 01/28/13 11:32 AM 01/30/23 11:40 AM AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA en LSR /LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Pro-RBM-Kidney-Toxicity-Assays N 0 <p>The <a href="/evportal/destination/commerce/product_detail?catID=MH3RQ8E8Z">Bio-Plex Pro human kidney toxicity</a> panel 2 immunoassay is an all-in-one 1 x 96-well kit that includes premixed magnetic capture beads and detection antibodies, standards, 2-level controls, standard diluent, buffers (blocking, sample dilution, and 10x assay), 10x streptavidin-PE, flat bottom plate/seals, and instructions for the detection of the following analytes:</p> <ul> <li>Albumin</li> <li>B2M</li> <li>Cystatin C</li> <li>NGAL</li> <li>Osteopontin</li> <li>TFF3</li> </ul> <p>Instrument Compatibility</p> <ul> <li><a href="/evportal/destination/commerce/product_detail?catID=M3VE8D15">Bio-Plex<sup>&reg;</sup> MAGPIX&trade; multiplex reader</a></li> <li><a href="/evportal/destination/commerce/product_detail?catID=715b85f1-6a4e-41b3-b5d9-80202d779e13">Bio-Plex<sup>&reg;</sup> 200 system</a></li> <li><a href="/evportal/destination/commerce/product_detail?catID=L1AW4B15">Bio-Plex 3D suspension array system</a></li> <li><a href="/evportal/destination/commerce/product_detail?catID=2d1708e6-6b73-4329-833a-07881e7dd82c">Bio-Plex Pro wash stations</a></li> </ul> /webroot/web/html/lsr/products/bioplex_suspension_array/sku_view/description/global bio-plex-pro-rbm-human-kidney-toxicity-panel-2-171-atr2ck-desc.html /webroot/web/html/lsr/products/bioplex_suspension_array/sku_view/description/global/en-us/category/bio-plex-multiplex-immunoassay-system?ID=85824182-db2a-4c6e-ac82-4e07dd9ab904-pro-rbm-human-kidney-toxicity-panel-2-171-atr2ck-desc.html 1 0 false false false /prd/en/CA/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=171ATR2CK&CartQuote=QT&quantity= false true false $2,105.00 false null /prd/en/CA/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=171ATR2CK&AddToDefaultWishList=true&quantity= true false true true false true true true /prd/en/CA/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=171ATR2CK&quantity= 171ATR2CK
List Price: 
 
$2,105.00 
LoadingLoading...
EDU Price:
  What is this?
Your Price: 
 
LoadingLoading...
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Cart
 
 
x

Account price failed to display. Please try reloading the page.Reload Page

If you are placing an order, you may proceed with your order; the account price will be applied if it is lower than the
list price. If the problem persists, please call customer service at or send an
email to

Bio-Plex® Handheld Magnetic Washer

171020100
Includes magnetic washer and adjustment hex tools for use in manual wash steps for all Bio-Plex Magnetic Assays

171020100 /templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Instruments/171-020100_1326308046.xml 171020100 <?xml version="1.0" encoding="UTF-8"?> <Deployments> <Node Name="QA"> <Deployment Id="StandardMetadata.jd0nat6jjd0nat6k" Class="com.interwoven.livesite.lscs.model.LSCSDeploymentImpl" Instance="jd0nat6jjd0nat6k"> <Name>StandardMetadata</Name> <TargetEnviroment>QA</TargetEnviroment> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="30" DayOfWeek="2" Year="2018" Hour="0" Minute="25" Second="1" ZoneOffsetMillis="0" Time="1517271901984">Tue Jan 30 00:25:01 UTC 2018</LastExecutionTime> </Deployment> <Vpath>/default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Instruments/171-020100_1326308046.xml</Vpath> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="30" DayOfWeek="2" Year="2018" Hour="0" Minute="25" Second="1" ZoneOffsetMillis="0" Time="1517271901984">Tue Jan 30 00:25:01 UTC 2018</LastExecutionTime> </Node> <Node Name="PRODWEST"> <Deployment Id="StandardMetadata.jcrucwugjcrucwun" Class="com.interwoven.livesite.lscs.model.LSCSDeploymentImpl" Instance="jcrucwugjcrucwun"> <Name>StandardMetadata</Name> <TargetEnviroment>PRODWEST</TargetEnviroment> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="23" DayOfWeek="2" Year="2018" Hour="21" Minute="8" Second="34" ZoneOffsetMillis="0" Time="1516741714289">Tue Jan 23 21:08:34 UTC 2018</LastExecutionTime> </Deployment> <Vpath>/default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Instruments/171-020100_1326308046.xml</Vpath> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="23" DayOfWeek="2" Year="2018" Hour="21" Minute="8" Second="34" ZoneOffsetMillis="0" Time="1516741714289">Tue Jan 23 21:08:34 UTC 2018</LastExecutionTime> </Node> <Node Name="PRODEAST"> <Deployment Id="StandardMetadata.jcrucwugjcrucwuh" Class="com.interwoven.livesite.lscs.model.LSCSDeploymentImpl" Instance="jcrucwugjcrucwuh"> <Name>StandardMetadata</Name> <TargetEnviroment>PRODEAST</TargetEnviroment> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="23" DayOfWeek="2" Year="2018" Hour="20" Minute="31" Second="31" ZoneOffsetMillis="0" Time="1516739491247">Tue Jan 23 20:31:31 UTC 2018</LastExecutionTime> </Deployment> <Vpath>/default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Instruments/171-020100_1326308046.xml</Vpath> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="23" DayOfWeek="2" Year="2018" Hour="20" Minute="31" Second="31" ZoneOffsetMillis="0" Time="1516739491247">Tue Jan 23 20:31:31 UTC 2018</LastExecutionTime> </Node> <Node Name="PROD"> <Deployment Id="StandardMetadata.jd0nau7rjd0nau7s" Class="com.interwoven.livesite.lscs.model.LSCSDeploymentImpl" Instance="jd0nau7rjd0nau7s"> <Name>StandardMetadata</Name> <TargetEnviroment>PROD</TargetEnviroment> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="31" DayOfWeek="3" Year="2018" Hour="3" Minute="24" Second="37" ZoneOffsetMillis="0" Time="1517369077997">Wed Jan 31 03:24:37 UTC 2018</LastExecutionTime> </Deployment> <Vpath>/default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Instruments/171-020100_1326308046.xml</Vpath> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="31" DayOfWeek="3" Year="2018" Hour="3" Minute="24" Second="37" ZoneOffsetMillis="0" Time="1517369077997">Wed Jan 31 03:24:37 UTC 2018</LastExecutionTime> </Node> </Deployments> 01/11/12 10:16 AM en_US jal7kci7 2017-11-14 07:07:44 true true internet/product_SKU LSR N en 01/11/22 10:53 AM 1517369316185 AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA 2017-11-14 07:07:44 171020100-bio-plex-handheld-magnetic-washer 171020100 Bio-Plex Hand Held Magnetic Washer Bio-Plex<sup>&reg;</sup> Handheld Magnetic Washer Includes magnetic washer and adjustment hex tools for use in manual wash steps for all Bio-Plex Magnetic Assays Includes magnetic washer and adjustment hex tools for use in manual wash steps for all Bio-Plex Magnetic Assays /webroot/web/images/lsr/products/bioplex_suspension_array/sku_thumb/global/171-020100_tn.jpg /webroot/web/images/lsr/products/bioplex_suspension_array/sku_view/global/171-020100_view.jpg Amy Gumiran Bio-Plex Hand Held Magnetic Washer Includes magnetic washer and adjustment hex tools for use in manual wash steps for all Bio-Plex Magnetic Assays 171020100, bio-plex, handheld, magnetic, washer, adjustment, hex, tools, manual, wash, assays, immunoassays, singleplex, multiplex 01/11/12 10:16 AM 01/11/22 10:53 AM AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA en LSR /LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Instruments N 0 1 0 false false false /prd/en/CA/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=171020100&CartQuote=QT&quantity= false true false $1,084.00 false null /prd/en/CA/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=171020100&AddToDefaultWishList=true&quantity= true false true true false true true true /prd/en/CA/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=171020100&quantity= 171020100
List Price: 
 
$1,084.00 
LoadingLoading...
EDU Price:
  What is this?
Your Price: 
 
LoadingLoading...
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Cart
 
 
Bio-Plex Pro™ Flat Bottom Plates

171025001
Pkg of 40, 96-well plate, for use with Bio-Plex Pro wash stations when using magnetic bead–based assays

171025001 /templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Pro-Magnetic-Cytokine/171-025001_0921120724536.xml 171025001 <?xml version="1.0" encoding="UTF-8"?> <Deployments> <Node Name="QA"> <Deployment Id="StandardMetadata.jd0nat6jjd0nat6k" Class="com.interwoven.livesite.lscs.model.LSCSDeploymentImpl" Instance="jd0nat6jjd0nat6k"> <Name>StandardMetadata</Name> <TargetEnviroment>QA</TargetEnviroment> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="30" DayOfWeek="2" Year="2018" Hour="0" Minute="25" Second="1" ZoneOffsetMillis="0" Time="1517271901984">Tue Jan 30 00:25:01 UTC 2018</LastExecutionTime> </Deployment> <Vpath>/default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Pro-Magnetic-Cytokine/171-025001_0921120724536.xml</Vpath> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="30" DayOfWeek="2" Year="2018" Hour="0" Minute="25" Second="1" ZoneOffsetMillis="0" Time="1517271901984">Tue Jan 30 00:25:01 UTC 2018</LastExecutionTime> </Node> <Node Name="PRODWEST"> <Deployment Id="StandardMetadata.jcrucwugjcrucwun" Class="com.interwoven.livesite.lscs.model.LSCSDeploymentImpl" Instance="jcrucwugjcrucwun"> <Name>StandardMetadata</Name> <TargetEnviroment>PRODWEST</TargetEnviroment> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="23" DayOfWeek="2" Year="2018" Hour="21" Minute="8" Second="34" ZoneOffsetMillis="0" Time="1516741714289">Tue Jan 23 21:08:34 UTC 2018</LastExecutionTime> </Deployment> <Vpath>/default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Pro-Magnetic-Cytokine/171-025001_0921120724536.xml</Vpath> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="23" DayOfWeek="2" Year="2018" Hour="21" Minute="8" Second="34" ZoneOffsetMillis="0" Time="1516741714289">Tue Jan 23 21:08:34 UTC 2018</LastExecutionTime> </Node> <Node Name="PRODEAST"> <Deployment Id="StandardMetadata.jcrucwugjcrucwuh" Class="com.interwoven.livesite.lscs.model.LSCSDeploymentImpl" Instance="jcrucwugjcrucwuh"> <Name>StandardMetadata</Name> <TargetEnviroment>PRODEAST</TargetEnviroment> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="23" DayOfWeek="2" Year="2018" Hour="20" Minute="31" Second="31" ZoneOffsetMillis="0" Time="1516739491247">Tue Jan 23 20:31:31 UTC 2018</LastExecutionTime> </Deployment> <Vpath>/default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Pro-Magnetic-Cytokine/171-025001_0921120724536.xml</Vpath> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="23" DayOfWeek="2" Year="2018" Hour="20" Minute="31" Second="31" ZoneOffsetMillis="0" Time="1516739491247">Tue Jan 23 20:31:31 UTC 2018</LastExecutionTime> </Node> <Node Name="PROD"> <Deployment Id="StandardMetadata.jd0nau7rjd0nau7s" Class="com.interwoven.livesite.lscs.model.LSCSDeploymentImpl" Instance="jd0nau7rjd0nau7s"> <Name>StandardMetadata</Name> <TargetEnviroment>PROD</TargetEnviroment> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="31" DayOfWeek="3" Year="2018" Hour="3" Minute="24" Second="37" ZoneOffsetMillis="0" Time="1517369077997">Wed Jan 31 03:24:37 UTC 2018</LastExecutionTime> </Deployment> <Vpath>/default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Pro-Magnetic-Cytokine/171-025001_0921120724536.xml</Vpath> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="31" DayOfWeek="3" Year="2018" Hour="3" Minute="24" Second="37" ZoneOffsetMillis="0" Time="1517369077997">Wed Jan 31 03:24:37 UTC 2018</LastExecutionTime> </Node> </Deployments> 09/21/09 12:07 PM en_US jal7kch3 2017-11-14 07:07:47 true true internet/product_SKU LSR N en 09/21/19 12:07 PM 1517369316860 AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA 2017-11-14 07:07:47 171025001-bio-plex-pro-flat-bottom-plates 171025001 Bio-Plex Pro Flat Bottom Plates Bio-Plex Pro&trade; Flat Bottom Plates Pkg of 40, 96-well plate, for use with Bio-Plex Pro wash stations when using magnetic bead&ndash;based assays Pkg of 40, 96-well plate, for use with Bio-Plex Pro wash stations when using magnetic bead-based assays Pkg of 40, 96-well plate, for use with Bio-Plex Pro wash stations when using magnetic bead&ndash;based assays /webroot/web/images/lsr/products/bioplex_suspension_array/sku_thumb/global/171-025001b_tn.jpg /webroot/web/images/lsr/products/bioplex_suspension_array/sku_view/global/171-025001b_view.jpg /webroot/web/images/lsr/products/bioplex_suspension_array/sku_feature/global/171-025001b_feature.jpg RepEx 171-025001 Pkg of 40, 96-well plate, for use with Bio-Plex Pro wash stations when using magnetic bead-based assays 171025001, bio-plex, pro, flat, bottom, plates, wash, stations, bioplex, multiplex, singleplex, bead-based, assay, assays, immunoassay, coupled, magnetic, beads, detection 09/21/09 12:07 PM 09/21/19 12:07 PM AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA en LSR /LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Pro-Magnetic-Cytokine N 0 30034376 /templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Instruments/300-34376_0921120736052.xml false false false /prd/en/CA/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=171025001&CartQuote=QT&quantity= false true false $346.00 false null /prd/en/CA/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=171025001&AddToDefaultWishList=true&quantity= true false true true false true true true /prd/en/CA/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=171025001&quantity= 171025001
List Price: 
 
$346.00 
LoadingLoading...
EDU Price:
  What is this?
Your Price: 
 
LoadingLoading...
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Cart
 
 
Bio-Plex Pro™ Wash Station

30034376
Microplate wash station for magnetic bead–based assays, includes magnetic plate carrier, waste bottle, 2 buffer bottles

30034376 /templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Instruments/300-34376_0921120736052.xml 30034376 <?xml version="1.0" encoding="UTF-8"?> <Deployments> <Node Name="QA"> <Deployment Id="StandardMetadata.jd0nat6jjd0nat6k" Class="com.interwoven.livesite.lscs.model.LSCSDeploymentImpl" Instance="jd0nat6jjd0nat6k"> <Name>StandardMetadata</Name> <TargetEnviroment>QA</TargetEnviroment> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="30" DayOfWeek="2" Year="2018" Hour="0" Minute="25" Second="1" ZoneOffsetMillis="0" Time="1517271901984">Tue Jan 30 00:25:01 UTC 2018</LastExecutionTime> </Deployment> <Vpath>/default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Instruments/300-34376_0921120736052.xml</Vpath> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="30" DayOfWeek="2" Year="2018" Hour="0" Minute="25" Second="1" ZoneOffsetMillis="0" Time="1517271901984">Tue Jan 30 00:25:01 UTC 2018</LastExecutionTime> </Node> <Node Name="PRODWEST"> <Deployment Id="StandardMetadata.jcrucwugjcrucwun" Class="com.interwoven.livesite.lscs.model.LSCSDeploymentImpl" Instance="jcrucwugjcrucwun"> <Name>StandardMetadata</Name> <TargetEnviroment>PRODWEST</TargetEnviroment> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="23" DayOfWeek="2" Year="2018" Hour="21" Minute="8" Second="34" ZoneOffsetMillis="0" Time="1516741714289">Tue Jan 23 21:08:34 UTC 2018</LastExecutionTime> </Deployment> <Vpath>/default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Instruments/300-34376_0921120736052.xml</Vpath> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="23" DayOfWeek="2" Year="2018" Hour="21" Minute="8" Second="34" ZoneOffsetMillis="0" Time="1516741714289">Tue Jan 23 21:08:34 UTC 2018</LastExecutionTime> </Node> <Node Name="PRODEAST"> <Deployment Id="StandardMetadata.jcrucwugjcrucwuh" Class="com.interwoven.livesite.lscs.model.LSCSDeploymentImpl" Instance="jcrucwugjcrucwuh"> <Name>StandardMetadata</Name> <TargetEnviroment>PRODEAST</TargetEnviroment> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="23" DayOfWeek="2" Year="2018" Hour="20" Minute="31" Second="31" ZoneOffsetMillis="0" Time="1516739491247">Tue Jan 23 20:31:31 UTC 2018</LastExecutionTime> </Deployment> <Vpath>/default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Instruments/300-34376_0921120736052.xml</Vpath> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="23" DayOfWeek="2" Year="2018" Hour="20" Minute="31" Second="31" ZoneOffsetMillis="0" Time="1516739491247">Tue Jan 23 20:31:31 UTC 2018</LastExecutionTime> </Node> <Node Name="PROD"> <Deployment Id="StandardMetadata.jd0nau7rjd0nau7s" Class="com.interwoven.livesite.lscs.model.LSCSDeploymentImpl" Instance="jd0nau7rjd0nau7s"> <Name>StandardMetadata</Name> <TargetEnviroment>PROD</TargetEnviroment> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="31" DayOfWeek="3" Year="2018" Hour="3" Minute="24" Second="37" ZoneOffsetMillis="0" Time="1517369077997">Wed Jan 31 03:24:37 UTC 2018</LastExecutionTime> </Deployment> <Vpath>/default/main/bio-rad/WORKAREA/default/templatedata/internet/product_SKU/data/LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Instruments/300-34376_0921120736052.xml</Vpath> <LastExecutionTime Class="java.util.Date" Month="1" DayOfMonth="31" DayOfWeek="3" Year="2018" Hour="3" Minute="24" Second="37" ZoneOffsetMillis="0" Time="1517369077997">Wed Jan 31 03:24:37 UTC 2018</LastExecutionTime> </Node> </Deployments> 09/21/09 12:07 PM en_US jal7kchp 2017-11-14 07:07:44 true true internet/product_SKU LSR N en 09/21/19 12:07 PM 1517369316228 AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA 2017-11-14 07:07:44 30034376-bio-plex-pro-wash-station 30034376 Bio-Plex Pro Wash Station Bio-Plex Pro&trade; Wash Station Microplate wash station for magnetic bead&ndash;based assays, includes magnetic plate carrier, waste bottle, 2 buffer bottles Microplate wash station for magnetic bead based assays, includes magnetic plate carrier, waste bottle, 2 liquid bottles Microplate wash station for magnetic bead&ndash; based assays, includes magnetic plate carrier, waste bottle, 2 buffer bottles /webroot/web/images/lsr/products/bioplex_suspension_array/sku_thumb/global/300-34376_tn.jpg /webroot/web/images/lsr/products/bioplex_suspension_array/sku_view/global/300-34376_view.jpg /webroot/web/images/lsr/products/bioplex_suspension_array/sku_feature/global/300-34376_feature.jpg RepEx 300-34376 Microplate wash station for magnetic bead&ndash; based assays, includes magnetic plate carrier, waste bottle, 2 liquid bottles 30034376, bio-plex, pro, wash, station, microplate, washing, magnetic-based, assays, plate, carrier 09/21/09 12:07 PM 09/21/19 12:07 PM AE,AI,AL,AM,AR,AT,AU,AZ,BA,BD,BE,BF,BG,BH,BN,BO,BR,BW,CA,CH,CL,CM,CN,CO,CR,CY,CZ,DE,DK,DO,DZ,EC,EE,EG,EH,ER,ES,ET,FI,FM,FO,FR,GA,GE,GF,GH,GP,GR,GT,GU,HK,HN,HR,HT,HU,ID,IE,IL,IN,IS,IT,JM,JO,JP,KE,KH,KR,KW,KZ,LB,LI,LK,LT,LU,LV,MA,MD,MG,MK,ML,MO,MQ,MS,MT,MU,MX,MY,NG,NI,NL,NO,NP,NZ,OM,PA,PE,PF,PG,PH,PK,PL,PR,PS,PT,PW,PY,QA,RO,RS,RU,SA,SB,SE,SG,SI,SK,SN,ST,SV,TG,TH,TN,TO,TR,TT,TW,TZ,UA,UG,UK,US,UY,UZ,VA,VE,VU,XK,YE,ZA en LSR /LSR/Bio-Plex-Suspension-Array-Syst/Bio-Plex-Instruments N 0 false false false /prd/en/CA/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=30034376&CartQuote=QT&quantity= false true false null false null /prd/en/CA/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=30034376&AddToDefaultWishList=true&quantity= true false true true false true true true /prd/en/CA/adirect/biorad?cmd=ajaxAddToCart&AddToCartProductID=30034376&quantity= 30034376
List Price: 
 
Inquire
LoadingLoading...
EDU Price:
  What is this?
Your Price: 
 
LoadingLoading...
Your Price:
 

Communication error

Reload Page

Quantity:   Add to Cart
 
 
Number Description Options
6458 Bio-Plex Success Guide/Assay Sample Prep, Rev B Click to download
6335 Bio-Plex® Multiplex Immunoassays Analyte Guide, Rev E Click to download [ Add to Cart (Free) ]
10028258 Instruction Manual, Bio-Plex Pro RBM Kidney Toxicity Assays, Rev A Click to download
10028259 Instruction Manual, Bio-Plex Pro RBM Kidney Toxicity Assays Quick Guide, Rev B Click to download
6335 Bio-Plex® Multiplex Immunoassays Analyte Guide, Rev E Click to download [ Add to Cart (Free) ]
6347 Bio-Plex Pro RBM Assays Product Information Sheet, Rev A Click to download [ Add to Cart (Free) ]
6400 Profiling of Human, Canine, and Rat Urine Samples Using Bio-Plex Pro RBM Kidney Toxicity Assay, Rev A Click to download

This product contains electrical or electronic material. Learn more about Bio-Rad's EU Recycle Program

Get Help
Sign Up for Bio-Rad Updates!
Enter your email address below to receive your choice of the latest news, promotions, and more.