Bio-Plex 100 and 200 Components and Consumables

Bio-Plex 100 and 200 Components and Consumables

Overview

Components and consumables for Bio-Plex 100 and Bio-Plex 200 xMAP suspension array systems.
Read full description

Description

Description

The Bio-Plex 200 system integrates xMAP suspension array technology with a reliable workstation, dedicated software, and validation tools.

The following components and consumables can be ordered separately for the Bio-Plex 200 system: sample needle, alignment guide, needle adjustment wrench, protective shield for sample needle, air intake filter, syringe seal, syringe seal with cylinder, sheath fluid, sheath fluid bottle, sheath waste bottle, sheath fluid filter with quick connect tubing, sheath cube filter, sheath cube filter with tubing.

Specifications

Specifications

Environment conditions
 
Operating temperature
15–30°C (59–86°F)
Operating humidity
20–80%, noncondensing
Operating altitude
Designed to operate at up to 2,000 m (6,600') mean sea level
Compensatory range
±2°C
UL installation category
UL Installation Category II, as defined in Annex J of UL 3101–1
Pollution degree
UL Pollution Degree 2, as defined in Section 3.7, 3.2, of UL 3101–1
Bio-Plex Array Reader Specifications
 
Input voltage range
100–240 V, 1.5 A, 47 – 63 Hz
Physical dimensions
43 x 51 x 23 cm (W x D x H)
Weight
23 kg (60 lb)
Lasers
 
Reporter laser
532 nm, >10 mW, frequency-doubled diode; 30 x 60 µm elliptical beam
Classification laser
635 nm, 10 mW, diode; 30 x 60 µm elliptical beam
Fluidics
 
Sheath flow rate
90 µl/sec
Cuvette
200 µm square flow channel
Sample injection rates
60 µl/sec
Electronics
 
Reporter channel detection
Photomultiplier tube, A/D resolution 14 bits
Classification and doublet discriminator channel detection
Avalanche photodiodes with temperature compensation, A/D resolution 12 bits
Communication interface
RS–232
Signal Processing
 
Measurement resolution
15 bits effective
Processor modes
Linear, with logarithmic or linear display option
Dynamic range
70 dB
Bio-Plex Microplate Platform Specifications
 
Input voltage range
100–240 V, 1.8 A, 47–63 Hz
Physical dimensions
44 x 61 x 8 cm (W x D x H)
Weight
14.4 kg (32 lb)
Communications interface
RS–232
Plate capacity
One 96–well microtiter plate "≤0.75"

Ordering

Ordering

items

Use the filters below to refine results!

Image
171-020100_tn.jpg
171020100
Includes magnetic washer and adjustment hex tools for use in manual wash steps for all Bio-Plex Magnetic Assays
Image
171-000055_tn.jpg
(Discontinued) Sheath Fluid
171000055
20 L, 1x fluid in cube container with pour spout, for use with the Bio-Plex® 200 and Bio-Plex 3D system array readers and high-throughput fluidics (HTF) system
Image
171-002010_tn.jpg
(Discontinued) Sheath Fluid Bottle
171002010
Pkg of 1, 1 L polypropylene bottle with sheath-fluid and air-intake ports and tubing, for use with the Bio-Plex 200 system
Image
171-002024_tn.jpg
171002024
Pkg of 1, replacement fitting and blue shipping pin for Bio-Plex 200 system; aligns array reader on microplate platform
Image
171-002038_tn.jpg
171002038
Pkg of 1, replacement maintenance part for internal fluidics system on the Bio-Plex 200 system; removes >5 μm diameter particles
Image
171-002040_tn.jpg
(Discontinued) Sheath Cube Filter
171002040
Pkg of 1, replacement maintenance part for use with high-throughput fluidics (HTF) system and Bio-Plex 200 system; removes >10 µm diameter particles
Image
171-002056_tn.jpg
(Discontinued) HTF Tubing
171002056
Pkg of 1, air tubing HTF to reader, sheath tubing HTF to reader, tubing sheath container to HTF (including 10 µm filter), and waste tubing (reader to waste container)
Image
171-002001_tn.jpg
(Discontinued) Communication Cable
171002001
Pkg of 1, 5 ft DB9 cable, connects Bio-Plex 200 system microplate platform with PC serial port

Documents

Documents

Number Description Options
3076
Bio-Plex Care and Maintenance Quick Guide, Rev B
2993
Bio-Plex Glossary, Rev A
4100205
Bio-Plex Maintenance Log, Rev A
2879
Bio-Plex System Tools Brochure, Rev C
3000
Correlation of Bio-Plex Suspension Array Reader Validation With Multiplex Cytokine Assay Performance, Rev A